      Improvement of the fluorine-18 fluorodeoxyglucose images in simultaneous F-18 FDG/Tc-99m collimated spect imaging.

      Medical physics
      Biophysical Phenomena, Biophysics, Fluorine Radioisotopes, diagnostic use, Fluorodeoxyglucose F18, Heart, radionuclide imaging, Humans, Image Processing, Computer-Assisted, Phantoms, Imaging, Radiopharmaceuticals, Scattering, Radiation, Technetium Tc 99m Sestamibi, Tomography, Emission-Computed, Single-Photon, methods

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Collimated F-18 FDG SPECT imaging has been shown to be an acceptable alternative to F-18 FDG PET imaging for evaluating injured but viable myocardium. Ultra-energy (UHE) imaging is usually performed in simultaneous F-18 FDG/Tc-99m MIBI studies. The main limitations of this technique are degradation of the Tc-99m MIBI images due to F-18 downscatter to the Tc-99m window, and loss of resolution in Tc-99m images caused by using a UHE rather than a low-energy collimator. The quality of F-18 images has not been addressed. In our clinical and phantom studies we have found that F-18 images are inferior to simultaneously acquired Tc-99m MIBI images. This paper compares two correction methods for F-18 FDG images in a realistic cardiac phantom study. One approach is subtractive scatter correction, which employs a third 410 keV energy window image to estimate scatter. The other approach is based on restoration. The phantom acquisition was performed with 7.2 MBq of F-18 and 22.2 MBq of Tc-99m injected into the left ventricular (LV) wall. Three inserts, 3 cm, 2 cm, and 1 cm in diameter, were placed in the LV wall to simulate infarcts. Circumferential profiles were drawn from three successive short-axis slices and compared with true phantom data. The differences were calculated as root-mean-square error (rmse). Scatter correction improved rmse only 4.5 +/- 0.3%, while restoration improved rmse 16.1 +/- 0.4%, when compared with raw data. The same differences, measured as rmse, were 9.5 +/- 0.5, 6.8 +/- 0.4, and 5.1 +/- 0.5 for raw, scatter corrected, and restored F-18 data, respectively, when compared with Tc-99m window 140 keV data. The amount of noise, measured as root-mean-square % (rms%) was 5.3 +/- 0.5% for the Tc-99m image, 4.9 +/- 0.7% for the F-18 restored image, 6.2 +/- 0.6% for the raw F-18 image, and 6.5 +/- 0.9% for the scatter corrected F-18 image. The contrast measured for 2 cm and 3 cm inserts was 0.17 +/- 0.07 and 0.26 +/- 0.06 for F-18 raw data, 0.19 +/- 0.08 and 0.29 +/- 0.06 for the scatter corrected F-18 image, and 0.28 +/- 0.06 and 0.43 +/- 0.07 for the restored F-18 image. The contrast was 0.20 +/- 0.07 and 0.46 +/- 0.05 for the Tc-99m 140 keV window image. The restoration approach provided F-18 images of better contrast and detectibility than uncorrected or scatter corrected F-18 images. Restored F-18 images match better with the simultaneously acquired Tc-99m images.

          Related collections

          Author and article information

          Comments

          Comment on this article