4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Effects of storage temperature on the mechanical properties of porcine kidney estimated using shear wave elastography.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The objective of this study was to evaluate the effects of different conservation techniques on the mechanical properties of the ex vivo porcine kidney in order to select an appropriate conservation protocol to use prior to mechanical testing. Five groups of eight kidneys each were subjected to different methods of conservation: storage at 4°C, -18°C, -34°C and -71°C, for 7 days, or storage at 20°C for 2 days only (as the tissues degraded quickly). Their shear modulus as a function of depth in the organ was evaluated before (fresh) and after conservation using shear wave elastography. Results obtained on fresh kidneys were collected within 6h of death. Freezing lead to a significant decrease (p<0.05) of the shear modulus in the most superficial zone (renal cortex), irrespectively of the freezing temperature (-18°C, -34°C, -71°C). There were no significant change (p>0.05) in the properties of the renal cortex when stored at 4°C or 20°C. The average moduli in the central region of the kidney (medulla) were much higher than in the cortex and exhibited also exhibited larger specimen to specimen variations. The effects of the conservation method on the central region were not significant. Overall, the results suggest that kidney tissues should not be frozen prior to biomechanical characterization and that inhomogeneity may be important to consider for in biomechanical models.

          Related collections

          Author and article information

          Journal
          J Mech Behav Biomed Mater
          Journal of the mechanical behavior of biomedical materials
          1878-0180
          1878-0180
          Dec 2013
          : 28
          Affiliations
          [1 ] Université de Lyon, F-69622, Lyon, France; IFSTTAR, LBMC, UMR_T9406, F-69675 Bron, France; Université Lyon 1, F-69622, Villeurbanne, France.
          Article
          S1751-6161(13)00243-9
          10.1016/j.jmbbm.2013.07.012
          23973616
          ace92372-00fc-4239-8f6f-632b3e1a08fa
          © 2013 Elsevier Ltd. All rights reserved.
          History

          Elastography,Freezing,Imaging,Kidney,Porcine,Shear modulus
          Elastography, Freezing, Imaging, Kidney, Porcine, Shear modulus

          Comments

          Comment on this article