      Radiation dose verification using real tissue phantom in modern radiotherapy techniques

      other

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          In vitro dosimetric verification prior to patient treatment has a key role in accurate and precision radiotherapy treatment delivery. Most of commercially available dosimetric phantoms have almost homogeneous density throughout their volume, while real interior of patient body has variable and varying densities inside. In this study an attempt has been made to verify the physical dosimetry in actual human body scenario by using goat head as “head phantom” and goat meat as “tissue phantom”. The mean percentage variation between planned and measured doses was found to be 2.48 (standard deviation (SD): 0.74), 2.36 (SD: 0.77), 3.62 (SD: 1.05), and 3.31 (SD: 0.78) for three-dimensional conformal radiotherapy (3DCRT) (head phantom), intensity modulated radiotherapy (IMRT; head phantom), 3DCRT (tissue phantom), and IMRT (tissue phantom), respectively. Although percentage variations in case of head phantom were within tolerance limit (< ± 3%), but still it is higher than the results obtained by using commercially available phantoms. And the percentage variations in most of cases of tissue phantom were out of tolerance limit. On the basis of these preliminary results it is logical and rational to develop radiation dosimetry methods based on real human body and also to develop an artificial phantom which should truly represent the interior of human body.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: found
          • Article: not found

          Dosimetry tools and techniques for IMRT.

          Intensity modulated radiation therapy (IMRT) poses a number of challenges for properly measuring commissioning data and quality assurance (QA) radiation dose distributions. This report provides a comprehensive overview of how dosimeters, phantoms, and dose distribution analysis techniques should be used to support the commissioning and quality assurance requirements of an IMRT program. The proper applications of each dosimeter are described along with the limitations of each system. Point detectors, arrays, film, and electronic portal imagers are discussed with respect to their proper use, along with potential applications of 3D dosimetry. Regardless of the IMRT technique utilized, some situations require the use of multiple detectors for the acquisition of accurate commissioning data. The overall goal of this task group report is to provide a document that aids the physicist in the proper selection and use of the dosimetry tools available for IMRT QA and to provide a resource for physicists that describes dosimetry measurement techniques for purposes of IMRT commissioning and measurement-based characterization or verification of IMRT treatment plans. This report is not intended to provide a comprehensive review of commissioning and QA procedures for IMRT. Instead, this report focuses on the aspects of metrology, particularly the practical aspects of measurements that are unique to IMRT. The metrology of IMRT concerns the application of measurement instruments and their suitability, calibration, and quality control of measurements. Each of the dosimetry measurement tools has limitations that need to be considered when incorporating them into a commissioning process or a comprehensive QA program. For example, routine quality assurance procedures require the use of robust field dosimetry systems. These often exhibit limitations with respect to spatial resolution or energy response and need to themselves be commissioned against more established dosimeters. A chain of dosimeters, from secondary standards to field instruments, is established to assure the quantitative nature of the tests. This report is intended to describe the characteristics of the components of these systems; dosimeters, phantoms, and dose evaluation algorithms. This work is the report of AAPM Task Group 120.
            Bookmark
            • Record: found
            • Abstract: not found
            • Book: not found

            Introduction to Radiological Physics and Radiation Dosimetry

              Bookmark
              • Record: found
              • Abstract: not found
              • Book: not found

              The Physics of Radiation Therapy

                Bookmark

                Author and article information

                Journal
                J Med Phys
                J Med Phys
                JMP
                Journal of Medical Physics / Association of Medical Physicists of India
                Medknow Publications & Media Pvt Ltd (India )
                0971-6203
                1998-3913
                Jan-Mar 2014
                : 39
                : 1
                : 44-49
                Affiliations
                [1 ], [3 ]Department of Physics, Mewar University, Chittorgarh, Rajasthan
                [1 ], [2 ]Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore, Madhya Pradesh, India
                [3 ]Department of Radiotherapy, Dr. Ram Manohar Lohia Institute of Medical Sciences, Lucknow, India
                Author notes
                Address for correspondence: Mr. Om Prakash Gurjar, (Ph. D. Scholar - Mewar University), Asstt. Professor (Medical Physics) cum RSO (III) Roentgen-SAIMS Radiation Oncology Centre, Sri Aurobindo Institute of Medical Sciences, Indore - 453 111, Madhya Pradesh, India. E-mail: ominbarc@ 123456gmail.com
                Article
                JMP-39-44
                10.4103/0971-6203.125504
                3931228
                24600172
                adc56d84-5965-4cf5-a553-b787848cab66
                Copyright: © Journal of Medical Physics

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 19 July 2013
                : 31 October 2013
                : 31 October 2013
                Categories
                Technical Note

                Medical physics
                head phantom,millennium 80 multileaf collimator system,real tissue,tissue phantom

                Comments

                Comment on this article