      Intracardiac electrogram T-wave alternans/variability increases before spontaneous ventricular tachyarrhythmias in implantable cardioverter-defibrillator patients: a prospective, multi-center study.

      Circulation
      Aged, Defibrillators, Implantable, Electrophysiologic Techniques, Cardiac, methods, Female, Humans, Male, Middle Aged, Prospective Studies, Tachycardia, Supraventricular, physiopathology, Tachycardia, Ventricular, diagnosis

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          T-wave alternans (TWA) increases before ventricular tachycardia (VT) or fibrillation (VF), suggesting that it may warn of VT/VF in implantable cardioverter-defibrillator patients. Recently, we described a method for measuring alternans and nonalternans variability (TWA/V) from electrograms (EGMs) stored in implantable cardioverter-defibrillators before VT/VF. The goal of this prospective, multicenter study was to determine whether EGM TWA/V was greater before VT/VF than at baseline. We enrolled 63 implantable cardioverter-defibrillator patients. TWA/V was computed from stored EGMs before spontaneous VT/VF and from sequential windows of 8 pairs of beats using 4 different control recordings: baseline rhythm, rapid pacing at 105 bpm, segments of ambulatory Holter EGMs matched to the time of VT/VF episodes, and EGMs before spontaneous supraventricular tachycardia. During follow-up, 28 patients had 166 episodes of VT/VF. TWA/V was greater before VT/VF (62.9 ± 3.1 μV; n = 28) than during baseline rhythm (12.8 ± 1.8 μV; P < 0.0001; n = 62), during rapid pacing (14.5 ± 2.0 μV; P < 0.0001; n = 52), before supraventricular tachycardia (27.5 ± 6.1 μV; P < 0.0001; n = 9), or during time-matched ambulatory controls (12.3 ± 3.5 μV; P < 0.0001; n = 16). By logistic regression, the odds of VT/VF increased by a factor of 2.2 for each 10-μV increment in TWA/V (P < 0.0001). In implantable cardioverter-defibrillator patients, EGM TWA/V is greater before spontaneous VT/VF than in control recordings. Future implantable cardioverter-defibrillators that measure EGM TWA/V continuously may warn patients and initiate pacing therapies to prevent VT/VF.

          Related collections

          Author and article information

          Comments

          Comment on this article