      Electron energy loss spectroscopy for analysis of inhaled ultrafine particles in rat lungs.

      Microscopy Research and Technique
      Aerosols, Animals, Inhalation Exposure, Lung, chemistry, Male, Microscopy, Electron, Particle Size, Rats, Spectrum Analysis, methods, Titanium, analysis

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Epidemiologic studies have associated cardiovascular morbidity and mortality with ambient particulate air pollution. Particles smaller than 100 nm in diameter (ultrafine particles) are present in the urban atmosphere in very high numbers yet at very low mass concentration. Organs beyond the lungs are considered as targets for inhaled ultrafine particles, whereby the route of particle translocation deeper into the lungs is unclear. Five rats were exposed to aerosols of ultrafine titanium dioxide particles of a count median diameter of 22 nm (geometric standard deviation, GSD 1.7) for 1 hour. The lungs were fixed by intravascular perfusion of fixatives immediately thereafter. TiO(2) particles in probes of the aerosol as well as in systematic tissue samples were analyzed with a LEO 912 transmission electron microscope equipped with an energy filter for elemental microanalysis. The characteristic energy loss spectra were obtained by fast spectrum acquisition. Aerosol particles as well as those in the lung tissue were unambiguously identified by electron energy loss spectroscopy. Particles were mainly found as small clusters with a rounded shape. Seven percent of the particles in the lung tissue had a needle-like shape. The size distribution of the cluster profiles in the tissue had a count median diameter of 29 nm (GSD 1.7), which indicates no severe clustering or reshaping of the originally inhaled particles. Electron energy loss spectroscopy and related analytical methods were found to be suitable to identify and localize ultrafine titanium dioxide particles within chemically fixed and resin-embedded lung tissue. Copyright 2004 Wiley-Liss, Inc.

          Related collections

          Author and article information

          Journal
          15170760
          10.1002/jemt.20044

          Chemistry
          Aerosols,Animals,Inhalation Exposure,Lung,chemistry,Male,Microscopy, Electron,Particle Size,Rats,Spectrum Analysis,methods,Titanium,analysis

          Comments

          Comment on this article