      A Feasibility Study of Real-Time Remote CT Reading for Suspected Acute Appendicitis Using an iPhone.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          We aimed to evaluate the feasibility of an iPhone-based remote control system as a real-time remote computed tomography (CT) reading tool for suspected appendicitis using a third-generation (3G) network under suboptimal illumination. One hundred twenty abdominal CT scans were selected; 60 had no signs of appendicitis, whereas the remaining 60 had signs of appendicitis. The 16 raters reviewed the images using the liquid crystal display (LCD) monitor of a picture archiving and communication system (PACS) workstation, as well as using an iPhone connected to the PACS workstation via a remote control system. We graded the probability of the presence of acute appendicitis for each examination using a five-point Likert scale. The overall sensitivity and specificity for the diagnosis of suspected appendicitis using the iPhone and the LCD monitor were high, and they were not significantly different (sensitivity P = 1.00, specificity P = 0.14). The average areas under the receiver operating characteristic curves for all CT readings with the iPhone and LCD monitor were 0.978 (confidence interval 0.965-0.991) and 0.974 (0.960-0.988), respectively, and the two devices did not have significantly different diagnostic performances (P = 0.55). The inter-rater agreement for both devices was very good; the kappa value for the iPhone was 0.809 (0.793-0.826), and that for the LCD monitor was 0.817 (0.801-0.834). Each rater had moderate-to-very good intra-observer agreement between the two devices. We verified the feasibility of an iPhone-based remote control system as a real-time remote CT reading tool for identifying suspected appendicitis using a 3G network and suboptimal illumination.

          Related collections

          Author and article information

          Journal
          J Digit Imaging
          Journal of digital imaging
          Springer Science and Business Media LLC
          1618-727X
          0897-1889
          Aug 2015
          : 28
          : 4
          Affiliations
          [1 ] Department of Emergency Medicine, Hanyang University Guri Hospital, 153 Gyeongchun-ro(st), Guri-si, Gyeonggi-do, 471-701, Republic of Korea.