      Application of liquid chromatography/quadrupole-linear Ion trap mass spectrometry and time-of-flight mass spectrometry to the determination of pharmaceuticals and related contaminants in wastewater.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This paper describes an enhanced liquid chromatography-mass spectrometry (LC-MS) strategy for the analysis of a selected group of 56 organic pollutants in wastewater. This group comprises 38 pharmaceuticals and 10 of their most frequent metabolites, 6 pesticides, and 2 disinfectants. The LC-MS methodology applied is based in the use of a hybrid triple-quadrupole linear ion trap mass spectrometer (QTRAP) in combination with time-of-flight mass spectrometry (TOF-MS). The join application of both techniques provided very good results in terms of accurate quantification and unequivocal confirmation. Quantification was performed by LC-QTRAP-MS operating under selected reaction monitoring (SRM) mode in both positive and negative electrospray ionization. Unequivocal identification was provided by the acquisition of three SRM transitions per compound in most of the cases and by LC-TOF-MS analysis, which allows obtaining accurate mass measurements of the identified compounds with errors lower than 2 ppm. Additionally, the use of TOF-MS permits retrospective analysis, since the full spectrum is recorded at all times with a high sensitivity. Thus, review of recorded chromatograms looking for new compounds or transformation products suspected to be present in the samples is feasible allowing one to increase the scope of the method along the monitoring program. The analytical performance of the quantitative LC-QTRAP-MS method was evaluated in effluent wastewater samples. Linearity of response over 3 orders of magnitude was demonstrated for most compounds (R(2) > 0.99). Method limits of detection were between 0.04 and 50 ng L(-1). Finally, the methodology was successfully applied to a monitoring study intended to characterize wastewater effluents of six sewage treatment plants in Spain. The presence of most of compounds was detected at concentrations ranging from 9 ng L(-1) (atrazine) to 15 microg L(-1) (paraxanthine).

          Related collections

          Author and article information

          Journal
          Anal. Chem.
          Analytical chemistry
          American Chemical Society (ACS)
          0003-2700
          0003-2700
          Dec 15 2007
          : 79
          : 24
          Affiliations
          [1 ] Pesticide Residues Research Group, Department of Hydrogeology and Analytical Chemistry, University of Almería, 04120 La Cañada de San Urbano, Almería, Spain.
          Article
          10.1021/ac0715672
          18001124
          b241bb10-97c3-40da-a353-346fa37096f0
          History

          Comments

          Comment on this article