11
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Determination of the Representative Elementary Volume for the study of sandstones and siltstones by X-Ray microtomography

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          X-Ray computerized microtomography (µ-CT) besides providing two-dimensional images (2-D) of the transversal sections of the sample, the biggest attraction of the methodology is the rendering of three-dimensional images (3-D), enabling a more real analysis of the porous structure of the rock. However, the reconstruction, visualization and analysis of such 3-D images are limited in computer terms. Thus, it is not always possible to reconstruct the images with the total size of the microtomographed sample. Therefore, this study aims at determining the Representative Elementary Volume (REV) in reservoir rocks concerning their porosity. In order to collect microtomographic data from reservoir rocks, a microtomograph Skyscan model 1172 was utilized for the sandstone and siltstone samples scanning. After the analysis of the graphs obtained by REV, it was concluded that the most adequate dimensions for the reconstructed volume in each analyzed sample were approximately 1400 × 1400 × 1400 µm, which are dimensions that can easily be reconstructed, visualized and analyzed.

          Related collections

          Most cited references19

          • Record: found
          • Abstract: not found
          • Article: not found

          Pore level imaging of fluid transport using synchrotron X-ray microtomography

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Apparent and effective physical properties of heterogeneous materials: Representativity of samples of two materials from food industry

              Bookmark
              • Record: found
              • Abstract: not found
              • Book: not found

              Computed Tomography: Fundamentals, System Technology, Image Quality, Applications

                Bookmark

                Author and article information

                Contributors
                Role: ND
                Role: ND
                Role: ND
                Journal
                mr
                Materials Research
                Mat. Res.
                ABM, ABC, ABPol (São Carlos )
                1980-5373
                August 2012
                : 15
                : 4
                : 662-670
                Affiliations
                [1 ] Instituto Federal de Santa Catarina Brazil
                [2 ] Universidade Estadual de Londrina Brazil
                [3 ] Universidade Federal de Santa Catarina Brazil
                Article
                S1516-14392012000400027
                10.1590/S1516-14392012000400027
                b27a9919-29e6-49a7-9061-83187f7d444e

                http://creativecommons.org/licenses/by/4.0/

                History
                Product

                SciELO Brazil

                Self URI (journal page): http://www.scielo.br/scielo.php?script=sci_serial&pid=1516-1439&lng=en
                Categories
                ENGINEERING, CHEMICAL
                MATERIALS SCIENCE, MULTIDISCIPLINARY
                METALLURGY & METALLURGICAL ENGINEERING

                General materials science,General engineering
                representative elementary volume,X-ray microtomography,porosity,sandstone,siltstone

                Comments

                Comment on this article