      Mechanism of reentry induction by a 9-V battery in rabbit ventricles.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although the application of a 9-V battery to the epicardial surface is a simple method of ventricular fibrillation induction, the fundamental mechanisms underlying this process remain unstudied. We used a combined experimental and modelling approach to understand how the interaction of direct current (DC) from a battery may induce reentrant activity within rabbit ventricles and its dependence on battery application timing and duration. A rabbit ventricular computational model was used to simulate 9-V battery stimulation for different durations at varying onset times during sinus rhythm. Corresponding high-resolution optical mapping measurements were conducted on rabbit hearts with DC stimuli applied via a relay system. DC application to diastolic tissue induced anodal and cathodal make excitations in both simulations and experiments. Subsequently, similar static epicardial virtual electrode patterns were formed that interacted with sinus beats but did not induce reentry. Upon battery release during diastole, break excitations caused single ectopics, similar to application, before sinus rhythm resumed. Reentry induction was possible for short battery applications when break excitations were slowed and forced to take convoluted pathways upon interaction with refractory tissue from prior make excitations or sinus beats. Short-lived reentrant activity could be induced for battery release shortly after a sinus beat for longer battery applications. In conclusion, the application of a 9-V battery to the epicardial surface induces reentry through a complex interaction of break excitations after battery release with prior induced make excitations or sinus beats.

          Related collections

          Author and article information

          Journal
          Am. J. Physiol. Heart Circ. Physiol.
          American journal of physiology. Heart and circulatory physiology
          American Physiological Society
          1522-1539
          0363-6135
          Apr 01 2014
          : 306
          : 7
          Affiliations
          [1 ] Department of Biomedical Engineering, King's College London, London, United Kingdom;
          Article
          ajpheart.00591.2013
          10.1152/ajpheart.00591.2013
          3962639
          24464758
          b2edfca0-8ec8-47aa-b069-17dc73e6c42c
          History

          ventricular fibrillation,bidomain,cardiac modeling,optical mapping,reentry