          Abstract

          Die AngioVue-Technologie von Optovue für die optische Kohärenztomographie-Angiographie (OCT-A) basiert auf dem Bildgebungssystem AngioVue (Optovue Inc., Freemont, CA, USA) unter Verwendung des SSADA(split-spectrum amplitude-decorrelation angiography)-Algorithmus. Dieser Algorithmus ist darauf ausgelegt, die Dauer des Scan-Vorgangs zu minimieren. Er erkennt Bewegung im Blutgefäßlumen durch die Messung der Veränderungen in der reflektierten OCT-Signalamplitude bei aufeinanderfolgenden Querschnitt-Scans. Die Besonderheit der SSADA liegt in der Art, wie das OCT-Signal weiterverarbeitet wird, um die Flussmessung zu verbessern und das Signalrauschen der axialen Grundbewegung zu eliminieren. Konkret trennt der Algorithmus die OCT-Aufnahme in einzelne Spektralbänder auf und steigert dadurch die Anzahl verwertbarer Bild-Frames. Jeder neue Frame hat eine geringere axiale Auflösung, die weniger empfindlich gegenüber axialen Augenbewegungen infolge des pulsierenden Blutstroms ist. Die Technologie des AngioVue-Systems von Optovue ermöglicht eine quantitative Analyse. Sie liefert nummerische Daten über durchströmte sowie nicht durchströmte Areale und kann Flussdichtekarten erstellen. Diese aufbereiteten Messdaten könnten als Biomarker sowohl für die Diagnose als auch für die Überwachung des Krankheitsverlaufs und des Ansprechens auf eine Therapie dienen. Durchströmte Areale: Die Software berechnet das eingezeichnete Areal und das Gefäßareal in mm<sup>2</sup>. Sie ermöglicht auch den Vergleich aller Messungen einer Person. Nicht durchströmte Areale: Die Software zeigt die nicht durchbluteten Areale per Mausklick an. Ischämische Areale werden in Gelb dargestellt. Diese Areale können abgespeichert und mit anderen in der Studie abgeglichen werden. Mit dem Flussdichte-Tool lässt sich der prozentuale Anteil von vaskulären Arealen in En-Face-Angiogrammen messen. Die Analyse beruht auf einem ETDRS(Early Treatment Diabetic Retinopathy Study)-Raster, das wie die Dickenkarte auf die Makula zentriert ist. Das Tool ist sowohl für den inneren als auch für den äußeren Gefäßplexus geeignet. Übersetzung aus Dev Ophthalmol. Basel, Karger, 2016, vol 56, pp 6-12 (DOI:10.1159/000442770)

          Related collections

          Author and article information

          Journal
          KOP
          10.1159/issn.2297-0118
          Karger Kompass Ophthalmologie
          S. Karger AG
          2297-0118
          2297-0045
          2017
          May 2017
          02 May 2017
          : 3
          : 2
          : 58-63
          Affiliations
          aCasey Eye Institute, Oregon Health and Science University, Portland, OR, USA; bCentro Italiano Macula, Rome, Italy
          Author notes
          *Bruno Lumbroso, Centro Italiano Macula, Via Brofferio 7, 00195 Rom, Italien, bruno.lumbroso@gmail.com
          Article
          461906 Karger Kompass Ophthalmol 2017;3:58-63
          10.1159/000461906
          b4156685-c656-4b33-998a-18aabf00dd0d
          © 2017 S. Karger GmbH, Freiburg

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Figures: 3, References: 25, Pages: 6
          Categories
          Übersichtsarbeit

          Vision sciences,Ophthalmology & Optometry,Pathology
          Vision sciences, Ophthalmology & Optometry, Pathology

          Comments

          Comment on this article

          Related Documents Log