      In vitro Quantitation of Canine Left Ventricular Volume by Phased-Array Sector Scan

      research-article

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Ultrasonic sector-scan images can delineate the entire circumference of the canine left ventricle in vitro. This study was undertaken to (1) assess the accuracy of sector scanning for estimating canine left ventricular volume in vitro compared to volume estimates by M-mode echo in the same hearts and (2) determine the optimal techniques for estimating left ventricular volume with sector scanning. 16 volumes (1 volume from 8 hearts and 2 volumes from 4 hearts) were estimated by obtaining sector-scan images from orthogonal long-axis, short-axis and apical views. The sector-scan volumes were calculated by single and biplane area-length methods, as well as biplane Simpson’s rule methods, and compared to measured left ventricular volumes. M-mode echo volumes were calculated by cubing the mid-ventricular minor-axis diameter. Sector-scan views containing a long-axis dimension plus the short-axis dimension of the left ventricle had a high correlation with true left ventricular volume while sector-scan views not containing a long-axis view showed only a fair correlation with volume. M-mode echo produced a poor estimate of the true left ventricular volume. It is concluded that (1) sector scanning can provide highly accurate in vitro volume estimates of canine left ventricles which is superior to estimates derived by M-mode echocardiographic methods and (2) the optimal sector-scan views for estimating left ventricular volume are those that make the fewest assumptions about left ventricular geometry and have the greatest amount of dimensional information.

          Related collections

          Author and article information

          Journal
          CRD
          Cardiology
          10.1159/issn.0008-6312
          Cardiology
          S. Karger AG
          0008-6312
          1421-9751
          1981
          1981
          07 November 2008
          : 67
          : 1
          : 1-11
          Affiliations
          Division of Cardiology, Department of Electrical Engineering, Stanford University School of Medicine, Stanford, Calif.
          Article
          173223 Cardiology 1981;67:1–11
          10.1159/000173223
          7459904
          b4f1b957-01cd-4963-a0cb-11dcc4ea0e30
          © 1981 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          Page count
          Pages: 11
          Categories
          Original Paper

          General medicine,Neurology,Cardiovascular Medicine,Internal medicine,Nephrology
          Left ventricular volume,Sector scan,Two-dimensional echocardiography

          Comments

          Comment on this article