      A method detection limit for the analysis of natural organic matter via Fourier transform ion cyclotron resonance mass spectrometry.

      1 ,
      Analytical chemistry

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Fourier Transform Ion Cyclotron Resonance mass spectra (FT-ICR-MS) of natural organic matter are complex and consist of several thousands of peaks. The corresponding mass to charge ratios (m/z) and signal intensities result from analytes and noise. The most commonly applied way of distinguishing between analyte and noise is a fixed signal-to-noise ratio below which a detected peak is considered noise. However, this procedure is problematic and can yield ambiguous results. For example, random noise peaks can occur slightly above the signal-to-noise threshold (false positives), while peaks of low abundance analytes may occasionally fall below the fixed threshold (false negatives). Thus, cumulative results from repeated measurements of the same sample contain more peaks than a single measurement. False positive and false negative signals are difficult to distinguish, which affects the reproducibility between replicates of a sample. To target this issue, we tested the feasibility of a method detection limit (MDL) for the analysis of natural organic matter to identify peaks that can reliably be distinguished from noise by estimating the uncertainty of the noise. We performed 556 replicate analyses of a dissolved organic matter sample from the deep North Pacific on a 15 T FT-ICR-MS; each of these replicate runs consisted of 500 cumulated broadband scans. To unambiguously identify analyte peaks in the mass spectra, the sample was also run at time-consuming high-sensitivity settings. The resulting data set was used to establish and thoroughly test a MDL. The new method is easy to establish with software help, does only require the additional analysis of replicate blanks (low time increase), and can implement all steps of sample preparation. Especially when analysis time does not allow for replicate runs, major merits of the MDL are reliable removal of false positive (noise) peaks and better reproducibility, while the risk of losing analytes with low signal intensities (false negative) is comparatively low. When replicate analyses are feasible, the removal of all singly detected peaks is further recommended, as these have the highest probability of being noise peaks. We suggest that the here proposed detection limit should become routine in FT-ICR-MS data processing.

          Related collections

          Author and article information

          Journal
          Anal. Chem.
          Analytical chemistry
          1520-6882
          0003-2700
          Aug 19 2014
          : 86
          : 16
          Affiliations
          [1 ] Research Group for Marine Geochemistry (ICBM-MPI Bridging Group), Institute for Chemistry and Biology of the Marine Environment (ICBM) Carl von Ossietzky Universität Oldenburg , Carl-von-Ossietzky-Strasse 9-11, D-26129 Oldenburg, Germany.
          Article
          10.1021/ac501946m
          25068187
          b50b7443-63b5-4484-bc90-e6338ca4750b
          History

          Comments

          Comment on this article