A burn-up calculation of VVER's cores by Monte-Carlo code is complex process and requires large computational costs. This fact makes Monte-Carlo codes usage complicated for project and operating calculations. Previously prepared isotopic compositions are proposed to use for the Monte-Carlo code (MCU) calculations of different states of VVER's core with burnt fuel. Isotopic compositions are proposed to calculate by an approximation method. The approximation method is based on usage of a spectral functionality and reference isotopic compositions, that are calculated by engineering codes (TVS-M, PERMAK-A). The multiplication factors and power distributions of FA and VVER with infinite height are calculated in this work by the Monte-Carlo code MCU using earlier prepared isotopic compositions. The MCU calculation data were compared with the data which were obtained by engineering codes.
Die Berechnung des Abbrands eines WWER-Kerns mit einem Monte-Carlo-Programm ist komplex und erfordert einen sehr hohen Rechenaufwand. Daher ist die Nutzung von Monte-Carlo-Programmen für Betriebs- und Projektrechnungen selten. In diesem Beitrag wird gezeigt, dass vorbereitete isotope Brennstoffzusammensetzungen sehr gut als Eingangsgrößen für Monte-Carlo-Berechnungen verschiedener Kernzustände mit abgebranntem Brennstoff geeignet sind. Dabei werden die isotopen Brennstoffzusammensetzungen mit der Näherungsmethode basierend auf der Nutzung der spektralen Funktionalität und einer Referenzzusammensetzung mit Programmen wie TVS-M oder PERMAK-A berechnet. So werden die Multiplikationsfaktoren und der Leistungsverteilung von Brennelementen für WWER mit dem Monte-Carlo-Programm MCU bestimmt und mit den Ergebnissen der Programme TVS-M und PERMAK-A verglichen.