          Abstract

          Background

          Psychogenic pseudosyncope (PPS), a conversion disorder and syncope mimic, accounts for a large proportion of ‘unexplained syncope’. PPS is diagnosed by reproduction of patients’ symptoms during head-up tilt (HUT). Electroencephalogram (EEG), a time consuming and resource intensive technology, is used during HUT to demonstrate absence of cerebral hypoperfusion during transient loss of consciousness (TLOC). Near-infrared spectroscopy (NIRS) is a simple, non-invasive technology for continuous monitoring of cerebral perfusion. We present a series of patients for whom PPS diagnosis was supported by NIRS during HUT.

          Methods

          Eight consecutive patients with suspected PPS referred to a syncope unit underwent evaluation. During HUT, continuous beat-to-beat blood pressure (BP), heart rate (HR) and NIRS-derived tissue saturation index (TSI) were measured. BP, HR and TSI at baseline, time of first symptom, presyncope and apparent TLOC were measured. Patients were given feedback and followed for symptom recurrence.

          Results

          Eight predominantly female patients (6/8, 75%) aged 31 years (16–54) were studied with (5/8, 63%) having comorbid psychiatric diagnoses, and (5/8, 63%) presenting with frequent episodes of prolonged TLOC with eyes closed (6/8, 75%). All patients experienced reproduction of typical events during HUT. Systolic BP (mmHg) increased from baseline (129.7 (interquartile range [IQR] 124.9–133.4)) at TLOC (153.0 (IQR 146.7–159.0)) (P-value = 0.012). HR (bpm) increased from baseline 78 (IQR 68.6–90.0) to 115.7 (IQR 93.5–127.9) (P-value = 0.012). TSI (%) remained stable throughout, 71.4 (IQR 67.5–72.9) at baseline vs. 71.0 (IQR 68.2–73.0) at TLOC (P-value = 0.484).

          Conclusions

          NIRS provides a non-invasive surrogate of cerebral perfusion during HUT. We propose HUT incorporating NIRS monitoring in the diagnostic algorithm for patients with suspected PPS.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: not found
          • Article: not found

          2018 ESC Guidelines for the diagnosis and management of syncope

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Near-infrared spectroscopy as an index of brain and tissue oxygenation.

            Continuous real-time monitoring of the adequacy of cerebral perfusion can provide important therapeutic information in a variety of clinical settings. The current clinical availability of several non-invasive near-infrared spectroscopy (NIRS)-based cerebral oximetry devices represents a potentially important development for the detection of cerebral ischaemia. In addition, a number of preliminary studies have reported on the application of cerebral oximetry sensors to other tissue beds including splanchnic, renal, and spinal cord. This review provides a synopsis of the mode of operation, current limitations and confounders, clinical applications, and potential future uses of such NIRS devices.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Monitoring tissue oxygenation by near infrared spectroscopy (NIRS): background and current applications

              Conventional cardiovascular monitoring may not detect tissue hypoxia, and conventional cardiovascular support aiming at global hemodynamics may not restore tissue oxygenation. NIRS offers non-invasive online monitoring of tissue oxygenation in a wide range of clinical scenarios. NIRS monitoring is commonly used to measure cerebral oxygenation (rSO2), e.g. during cardiac surgery. In this review, we will show that tissue hypoxia occurs frequently in the perioperative setting, particularly in cardiac surgery. Therefore, measuring and obtaining adequate tissue oxygenation may prevent (postoperative) complications and may thus be cost-effective. NIRS monitoring may also be used to detect tissue hypoxia in (prehospital) emergency settings, where it has prognostic significance and enables monitoring of therapeutic interventions, particularly in patients with trauma. However, optimal therapeutic agents and strategies for augmenting tissue oxygenation have yet to be determined.
                Bookmark

                Author and article information

                Journal
                QJM: An International Journal of Medicine
                Oxford University Press (OUP)
                1460-2725
                1460-2393
                April 2020
                April 01 2020
                October 09 2019
                April 2020
                April 01 2020
                October 09 2019
                : 113
                : 4
                : 239-244
                Affiliations
                [1 ]Department of Medical Gerontology, Trinity College Dublin, Dublin, Ireland
                [2 ]Falls and Syncope Unit, Dublin, Ireland
                [3 ]Department of Medical Physics and Bioengineering, Mercer’s Institute for Successful Ageing, St James’s Hospital, Dublin, Ireland
                [4 ]Syncope Unit, Geriatric Intensive Care Medicine, University of Florence and Azienda Ospedaliero Universitaria Careggi, Florence, Italy