      Building Performance Evaluation of a New Hospital Building in the UK: Balancing Indoor Environmental Quality and Energy Performance

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Hospitals are controlled yet complex ecosystems which provide a therapeutic environment that promotes healing, wellbeing and work efficiency for patients and staff. As these buildings accommodate the sick and vulnerable, occupant wellbeing and good indoor environmental quality (IEQ) that deals with indoor air quality (IAQ), thermal comfort, lighting and acoustics are important objectives. As the specialist nature of hospital function demands highly controlled indoor environments, this makes them energy intensive buildings due to the complex and varying specifications for their functions and operations. This paper reports on a holistic building performance evaluation covering aspects of indoor air quality, thermal comfort, lighting, acoustics, and energy use. It assesses the performance issues and inter-relationships between IEQ and energy in a new building on a hospital campus in the city of Bristol, United Kingdom. The empirical evidence collated from this case study and the feedback received from the hospital staff help identify the endemic issues and constraints related to hospital buildings, such as the need for robust ventilation strategies in hospitals in urban areas that mitigate the effect of indoor and outdoor air pollution and ensuring the use of planned new low-carbon technologies. Whilst the existing guidelines for building design provide useful instructions for the protection of hospital buildings against ingress of particulate matter from outdoors, more advanced filtration strategies may be required to enact chemical reactions required to control the concentration levels of pollutants such as nitrogen dioxide and benzene. Further lessons for improved performance in operation and maintenance of hospitals are highlighted. These include ensuring that the increasingly available metering and monitoring data in new buildings, through building management systems, is used for efficient and optimal building operations for better IEQ and energy management. Overall, the study highlights the need for an integrated and holistic approach to building performance to ensure that healthy environments are provided while energy efficiency targets are met.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: not found
          • Article: not found

          Review of relationship between indoor and outdoor particles: I/O ratio, infiltration factor and penetration factor

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Impact of indoor environmental quality on occupant well-being and comfort: A review of the literature

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Hazard assessment of chemical air contaminants measured in residences.

              Identifying air pollutants that pose a potential hazard indoors can facilitate exposure mitigation. In this study, we compiled summary results from 77 published studies reporting measurements of chemical pollutants in residences in the United States and in countries with similar lifestyles. These data were used to calculate representative mid-range and upper-bound concentrations relevant to chronic exposures for 267 pollutants and representative peak concentrations relevant to acute exposures for five activity-associated pollutants. Representative concentrations are compared to available chronic and acute health standards for 97 pollutants. Fifteen pollutants appear to exceed chronic health standards in a large fraction of homes. Nine other pollutants are identified as potential chronic health hazards in a substantial minority of homes, and an additional nine are identified as potential hazards in a very small percentage of homes. Nine pollutants are identified as priority hazards based on the robustness of measured concentration data and the fraction of residences that appear to be impacted: acetaldehyde; acrolein; benzene; 1,3-butadiene; 1,4-dichlorobenzene; formaldehyde; naphthalene; nitrogen dioxide; and PM(2.5). Activity-based emissions are shown to pose potential acute health hazards for PM(2.5), formaldehyde, CO, chloroform, and NO(2). This analysis identifies key chemical contaminants of concern in residential indoor air using a comprehensive and consistent hazard-evaluation protocol. The identification of a succinct group of chemical hazards in indoor air will allow for successful risk ranking and mitigation prioritization for the indoor residential environment. This work also indicates some common household activities that may lead to the acute levels of pollutant exposure and identifies hazardous chemicals for priority removal from consumer products and home furnishings. Published 2010. This article is a US Government work and is in the public domain in the USA.
                Bookmark

                Author and article information

                Contributors
                Journal
                ATMOCZ
                Atmosphere
                Atmosphere
                MDPI AG
                2073-4433
                January 2021
                January 15 2021
                : 12
                : 1
                : 115
                Article
                10.3390/atmos12010115
                bdc237c0-6023-4d1c-9622-0cd8b0a85447
                © 2021

                https://creativecommons.org/licenses/by/4.0/

                History

                Comments

                Comment on this article