8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Diagnostic performance and prognostic value of serum troponin T in suspected acute myocardial infarction

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: not found
          • Article: not found

          The pathogenesis of coronary artery disease and the acute coronary syndromes (1).

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Diagnostic efficiency of troponin T measurements in acute myocardial infarction.

            The present study was designed to evaluate the efficiency of a newly developed troponin T enzyme immunoassay for the detection of acute myocardial infarction. The study comprised 388 patients admitted with chest pain and suspected myocardial infarction and 101 patients with skeletal muscle damage and additional suspected myocardial cell damage. Troponin T was elevated to more than twice the analytical sensitivity of the assay (0.5 microgram/l) in all patients with non-Q wave (range, 1.2-5 micrograms/l) and Q wave infarction (range, 3-220 micrograms/l). Troponin T appeared in serum as early as 3 hours after onset of pain in 50% of the patients and remained elevated in all patients for more than 130 hours, revealing release kinetics of both free cytosolic and structurally bound molecules. The diagnostic efficiency of troponin T was superior to that of creatine kinase-MB (98% versus 97%) and remained at 98% until 5.5 days after admission, if patients with unstable angina were excluded from analysis. In the 79 patients with unstable angina, troponin T was elevated (range, 0.55-3.1 micrograms/l) in at least one blood sample from each of 37 patients (56%). Circulating troponin T was correlated to the presence of reversible ST segment or T wave changes on the electrocardiogram (p less than 0.005) and to the frequency of in-hospital complications. In the 101 patients with skeletal muscle damage and suspected additional cardiac muscle damage, troponin T was the most useful test; its efficiency was 89% or 94% (depending on the discriminator value used) as compared with 63% for creatine kinase-MB. Thus, the data of the study indicate that the newly developed troponin T test improves the efficiency of serodiagnostic tools for the detection of myocardial cell necrosis as compared with conventionally used cardiac enzymes.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The prognostic value of serum troponin T in unstable angina.

              Cardiac troponin T is a regulatory contractile protein not normally found in blood. Its detection in the circulation has been shown to be a sensitive and specific marker for myocardial cell damage. We used a newly developed enzyme immunoassay for troponin T to determine whether its presence in the serum of patients with unstable angina was a prognostic indicator. We screened 109 patients with unstable angina (25 with accelerated or subacute angina and 84 with acute angina at rest) for serum creatine kinase activity, creatine kinase isoenzyme MB activity, and troponin T every eight hours for two days after admission to the hospital. The outcomes of interest during the hospitalization were death and myocardial infarction. Troponin T was detected (range, 0.20 to 3.64 micrograms per liter; mean, 0.78; median, 0.50) in the serum of 33 of the 84 patients (39 percent) with acute angina at rest. Only three of these patients had elevated creatine kinase MB activity (two were positive for troponin T, and one was negative). Of the 33 patients who were positive for troponin T, 10 (30 percent) had myocardial infarction (3 after coronary-artery bypass surgery), and 5 of these died during hospitalization. In contrast, only 1 of the 51 patients with angina at rest who were negative for troponin T had an acute myocardial infarction (P less than 0.001), and this patient died (P = 0.03). Thus, 10 of the 11 patients with myocardial infarctions had detectable levels of troponin T; only 1 had elevated creatine kinase MB activity. Troponin T was not detected in any of the 25 patients with accelerated or subacute angina, and none of these patients died. Cardiac troponin T in serum appears to be a more sensitive indicator of myocardial-cell injury than serum creatine kinase MB activity, and its detection in the circulation may be a useful prognostic indicator in patients with unstable angina.
                Bookmark

                Author and article information

                Journal
                Scandinavian Journal of Clinical and Laboratory Investigation
                Scandinavian Journal of Clinical and Laboratory Investigation
                Informa UK Limited
                0036-5513
                1502-7686
                July 08 2009
                January 1993
                July 08 2009
                January 1993
                : 53
                : 7
                : 677-685
                Article
                10.3109/00365519309092571
                bdcbb746-e777-4c70-8b5b-bc517a95fa1e
                © 1993
                History

                Comments

                Comment on this article