      Clinical experience with the Omnicarbon prosthetic heart valve.

      The Journal of Thoracic and Cardiovascular Surgery
      Adult, Aortic Valve, Female, Follow-Up Studies, Heart Valve Diseases, classification, mortality, surgery, Heart Valve Prosthesis, standards, Hospitals, University, Humans, Japan, epidemiology, L-Lactate Dehydrogenase, blood, Male, Middle Aged, Mitral Valve, Postoperative Complications, etiology, Risk Factors, Severity of Illness Index, Survival Rate

      Read this article at

      ScienceOpenPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The Omnicarbon prosthetic heart valve (Medical Inc., Inver Grove Heights, Minn.) was implanted in 124 patients (mean age 53 +/- 11 years); 66 of them had aortic valve replacement, 40 had mitral valve replacement, and 18 had both aortic and mitral valve replacement. Preoperatively 76.6% were in New York Heart Association class 3 or 4, and 84.7% were in class 1 or 2 after the operation. There were six (4.8%) early deaths and seven late deaths. Survival was 85% +/- 6% at 6 years in the aortic valve replacement group, 94% +/- 4% at 3 years in the mitral valve replacement group, and 78% +/- 11% at 4 years in the double valve replacement group. Freedom from cardiac death was 89% +/- 4% at 6 years (2.0% per patient-year) in the aortic valve replacement group, 94% +/- 4% at 3 years (1.8% per patient-year) in the mitral valve replacement group, and 78% +/- 11% at 4 years (5.7% per patient-year) in the double valve replacement group. There were six valve-related complications. Freedom from valve-related complications was 92% +/- 4% at 6 years (1.5% per patient-year) in the aortic valve replacement group, 97% +/- 3% at 3 years (1.8% per patient-year) in the mitral valve replacement group, and 83% +/- 11% at 4 years (5.7% per patient-year) in the double valve replacement group. Cerebral hemorrhage was seen in two patients in the aortic valve replacement group. Freedom from all events was 80% +/- 7% at 6 years in the aortic valve replacement group, 88% +/- 6% at 3 years in the mitral valve replacement group, and 78% +/- 11% at 4 years in the double valve replacement group. Elevation of the postoperative serum lactate dehydrogenase levels was minimal in all groups. The maximum opening angle at rest was 60.0 +/- 8.9 degrees in the aortic position and 54.1 +/- 6.6 degrees in the mitral position. In conclusion, the Omnicarbon prosthesis had excellent postoperative clinical status and negligible hemolysis.

          Related collections

          Author and article information

          Comments

          Comment on this article