2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Dual Amplification Fluorescence Assay for Alpha Fetal Protein Utilizing Immunohybridization Chain Reaction and Metal-Enhanced Fluorescence of Carbon Nanodots.

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As an emerging fascinating fluorescent nanomaterial, carbon nanodots (CDs) have attracted much attention owing of their unique properties such as small size, antiphotobleaching, and biocompatibility. However, its use in biomedical analysis is limited because of its low quantum yield. Herein, we constructed a dual amplification fluorescence sensor by incorporating immunohybridization chain reaction (immuno-HCR) and metal-enhanced fluorescence (MEF) of CDs for the detection of alpha fetal protein (AFP). The immunoplasmonic slide and detection antibodies-conjugated oligonucleotide initiator are served to capture and probe AFP molecules, respectively. Then, CD-tagged hairpin nucleic acids were introduced to trigger the HCR, in which the hairpin nucleic acid and oligonucleotide initiator are complementary. The interaction between CDs and the gold nanoisland film greatly improves the radiative decay rate, increases the quantum yield, and enhances the fluorescence emission of the CDs. Furthermore, the HCR provides secondary amplification of fluorescence intensity. Therefore, the MEF-capable immunohybridization reactions provide obvious advantages and result in exceptional sensitivity. In addition, the sandwich immunoassay method offers high specificity. The results show a wide linearity between the fluorescence intensity and AFP concentration over 5 orders of magnitude (0.0005-5 ng/mL), and the detection limit reaches as low as 94.3 fg/mL. This method offers advantages of high sensitivity and reliability, wide detection range, and versatile plasmonic chips, thus presenting an alternative for the technologies in biomedical analysis and clinical applications.

          Related collections

          Author and article information

          Journal
          ACS Appl Mater Interfaces
          ACS applied materials & interfaces
          American Chemical Society (ACS)
          1944-8252
          1944-8244
          Nov 01 2017
          : 9
          : 43
          Affiliations
          [1 ] Key Laboratory of Analytical Chemistry for Biology and Medicine (Ministry of Education), College of Chemistry and Molecular Sciences, Wuhan University , Wuhan 430072, People's Republic of China.
          [2 ] Hubei Cancer Hospital , Wuhan 430079, People's Republic of China.
          Article
          10.1021/acsami.7b11659
          28994579
          bee75397-a84e-4923-b301-e00609c0f9fa
          History

          HCR,MEF,sandwich immunoassays,AFP,CDs
          HCR, MEF, sandwich immunoassays, AFP, CDs

          Comments

          Comment on this article