      [Comparison of two quantitative methods of endobronchial ultrasound real-time elastography for evaluating intrathoracic lymph nodes].

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective: To compare the clinical value of two quantitative methods in analyzing endobronchial ultrasound real-time elastography (EBUS-RTE) images for evaluating intrathoracic lymph nodes. Methods: From January 2014 to April 2014, EBUS-RTE examination was performed in patients who received EBUS-TBNA examination in Shanghai Chest Hospital. Each intrathoracic lymph node had a selected EBUS-RTE image. Stiff area ratio and mean hue value of region of interest (ROI) in each image were calculated respectively. The final diagnosis of lymph node was based on the pathologic/microbiologic results of EBUS-TBNA, pathologic/microbiologic results of other examinations and clinical following-up. The sensitivity, specificity, positive predictive value, negative predictive value and accuracy were evaluated for distinguishing malignant and benign lesions. Results: Fifty-six patients and 68 lymph nodes were enrolled in this study, of which 35 lymph nodes were malignant and 33 lymph nodes were benign. The stiff area ratio and mean hue value of benign and malignant lesions were 0.32±0.29, 0.62±0.20 and 109.99±28.13, 141.62±17.52, respectively, and statistical differences were found in both of those two methods (t=-5.14, P<0.01; t=-5.53, P<0.01). The area under curves was 0.813, 0.814 in stiff area ratio and mean hue value, respectively. The optimal diagnostic cut-off value of stiff area ratio was 0.48, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 82.86%, 81.82%, 82.86%, 81.82% and 82.35%, respectively. The optimal diagnostic cut-off value of mean hue value was 126.28, and the sensitivity, specificity, positive predictive value, negative predictive value and accuracy were 85.71%, 75.76%, 78.95%, 83.33% and 80.88%, respectively. Conclusion: Both the stiff area ratio and mean hue value methods can be used for analyzing EBUS-RTE images quantitatively, having the value of differentiating benign and malignant intrathoracic lymph nodes, and the stiff area ratio is better than the mean hue value between the two methods.

          Related collections

          Author and article information

          Journal
          Zhonghua Jie He He Hu Xi Za Zhi
          Zhonghua jie he he hu xi za zhi = Zhonghua jiehe he huxi zazhi = Chinese journal of tuberculosis and respiratory diseases
          1001-0939
          1001-0939
          Jun 12 2017
          : 40
          : 6
          Affiliations
          [1 ] Department of Endoscopyand Pulmonary Medicine, Shanghai Chest Hospital, Shanghai Jiaotong University, Shanghai 200030, China.
          Article
          10.3760/cma.j.issn.1001-0939.2017.06.007
          28592025
          c2dec236-5320-491a-9103-3e3d1879e751
          History

          Bronchoscopy,Elastography,Endosonography,Lymph node,Quantitative methods

          Comments

          Comment on this article