39
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Automatic Classification of Artifactual ICA-Components for Artifact Removal in EEG Signals

      research-article
      1 , , 1 , 1
      Behavioral and Brain Functions : BBF
      BioMed Central

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Artifacts contained in EEG recordings hamper both, the visual interpretation by experts as well as the algorithmic processing and analysis (e.g. for Brain-Computer Interfaces (BCI) or for Mental State Monitoring). While hand-optimized selection of source components derived from Independent Component Analysis (ICA) to clean EEG data is widespread, the field could greatly profit from automated solutions based on Machine Learning methods. Existing ICA-based removal strategies depend on explicit recordings of an individual's artifacts or have not been shown to reliably identify muscle artifacts.

          Methods

          We propose an automatic method for the classification of general artifactual source components. They are estimated by TDSEP, an ICA method that takes temporal correlations into account. The linear classifier is based on an optimized feature subset determined by a Linear Programming Machine (LPM). The subset is composed of features from the frequency-, the spatial- and temporal domain. A subject independent classifier was trained on 640 TDSEP components (reaction time (RT) study, n = 12) that were hand labeled by experts as artifactual or brain sources and tested on 1080 new components of RT data of the same study. Generalization was tested on new data from two studies (auditory Event Related Potential (ERP) paradigm, n = 18; motor imagery BCI paradigm, n = 80) that used data with different channel setups and from new subjects.

          Results

          Based on six features only, the optimized linear classifier performed on level with the inter-expert disagreement ( <10% Mean Squared Error (MSE)) on the RT data. On data of the auditory ERP study, the same pre-calculated classifier generalized well and achieved 15% MSE. On data of the motor imagery paradigm, we demonstrate that the discriminant information used for BCI is preserved when removing up to 60% of the most artifactual source components.

          Conclusions

          We propose a universal and efficient classifier of ICA components for the subject independent removal of artifacts from EEG data. Based on linear methods, it is applicable for different electrode placements and supports the introspection of results. Trained on expert ratings of large data sets, it is not restricted to the detection of eye- and muscle artifacts. Its performance and generalization ability is demonstrated on data of different EEG studies.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Removing electroencephalographic artifacts by blind source separation.

          Eye movements, eye blinks, cardiac signals, muscle noise, and line noise present serious problems for electroencephalographic (EEG) interpretation and analysis when rejecting contaminated EEG segments results in an unacceptable data loss. Many methods have been proposed to remove artifacts from EEG recordings, especially those arising from eye movements and blinks. Often regression in the time or frequency domain is performed on parallel EEG and electrooculographic (EOG) recordings to derive parameters characterizing the appearance and spread of EOG artifacts in the EEG channels. Because EEG and ocular activity mix bidirectionally, regressing out eye artifacts inevitably involves subtracting relevant EEG signals from each record as well. Regression methods become even more problematic when a good regressing channel is not available for each artifact source, as in the case of muscle artifacts. Use of principal component analysis (PCA) has been proposed to remove eye artifacts from multichannel EEG. However, PCA cannot completely separate eye artifacts from brain signals, especially when they have comparable amplitudes. Here, we propose a new and generally applicable method for removing a wide variety of artifacts from EEG records based on blind source separation by independent component analysis (ICA). Our results on EEG data collected from normal and autistic subjects show that ICA can effectively detect, separate, and remove contamination from a wide variety of artifactual sources in EEG records with results comparing favorably with those obtained using regression and PCA methods. ICA can also be used to analyze blink-related brain activity.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            A well-conditioned estimator for large-dimensional covariance matrices

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Interpreting magnetic fields of the brain: minimum norm estimates.

              The authors have applied estimation theory to the problem of determining primary current distributions from measured neuromagnetic fields. In this procedure, essentially nothing is assumed about the source currents, except that they are spatially restricted to a certain region. Simulation experiments show that the results can describe the structure of the current flow fairly well. By increasing the number of measurements, the estimate can be made more localised. The current distributions may be also used as an interpolation and an extrapolation for the measured field patterns.
                Bookmark

                Author and article information

                Journal
                Behav Brain Funct
                Behavioral and Brain Functions : BBF
                BioMed Central
                1744-9081
                2011
                2 August 2011
                : 7
                : 30
                Affiliations
                [1 ]Machine Learning Laboratory, Berlin Institute of Technology, Franklinstr. 28/29, 10587 Berlin, Germany
                Article
                1744-9081-7-30
                10.1186/1744-9081-7-30
                3175453
                21810266
                c42e9f4a-cead-4695-86b7-dfe20dfaa541
                Copyright ©2011 Winkler et al; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 29 April 2011
                : 2 August 2011
                Categories
                Methodology

                Neurology
                Neurology

                Comments

                Comment on this article