      An Electroanalytical Solution for the Determination of Pb2+ in Progressive Hair Dyes Using the Cork-Graphite Sensor.

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Lead is one of the most toxic metals for living organisms: once absorbed by soft tissues, it is capable of triggering various pathologies, subsequently bioaccumulating in the bones. In consideration of this, its detection and quantification in products for human consumption and use is of great interest, especially if the procedure can be carried out in an easy, reproducible and economical way. This work presents the results of the electroanalytical determination of lead in three different commercial products used as progressive hair dyes. Analyses were performed by cyclic voltammetry (CV) and differential pulse stripping voltammetry (DPSV) using a composite cork-graphite sensor in 0.5M H2SO4 solution or 0.1M acetate buffer (pH 4.5), in the presence and absence of hair dye samples. The H2SO4 solution gave better results in terms of analyte sensitivity than the acetate buffer electrolyte. In both cases, well-defined signals for lead were obtained by DPSV analyses, enabling the calibration curve and figures of merit to be determined. The limits of detection (LOD) were found to be approximately 1.06 µM and 1.26 µM in H2SO4 and acetate buffer, respectively. The DPSV standard addition method was successfully applied to quantify the lead in hair dye samples, yielding values below 0.45% in Pb. All three analyzed samples were shown to comply with the limit set by the Brazilian Health Regulatory Agency, i.e., 0.6% lead in this type of product. The comparison of the electroanalytical results with those obtained by the reference method, based on the use of inductively coupled plasma optical emission spectrometry (ICP-OES), confirmed that the electroanalytical detection approach is potentially applicable as a strategy for quality control.

          Related collections

          Author and article information

          Journal
          Sensors (Basel)
          Sensors (Basel, Switzerland)
          MDPI AG
          1424-8220
          1424-8220
          Feb 14 2022
          : 22
          : 4
          Affiliations
          [1 ] Laboratório de Eletroquímica Ambiental e Aplicada, Instituto de Química, Universidade Federal do Rio Grande do Norte, Lagoa Nova, Natal 59.072-900, RN, Brazil.
          [2 ] Laboratório de Eletroquímica e Química Analítica, Programa de Pós Graduação em Ciências Naturais, Universidade do Estado do Rio Grande do Norte, Natal 59.610-210, RN, Brazil.
          [3 ] Department of Chemistry and Industrial Chemistry, University of Genova, 16146 Genova, Italy.
          [4 ] Ecas4 Australia Pty Ltd., Mile End South, SA 5031, Australia.