      Phacoemulsification versus phacoemulsification with micro-bypass stent implantation in primary open-angle glaucoma

      Journal of Cataract & Refractive Surgery
      Elsevier BV

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To compare phacoemulsification alone and phacoemulsification with micro-bypass stent implantation in eyes with primary open-angle glaucoma. Instituto di Fisiopatologia Clinica, Clinica Oculistica, Universita' di Torino, Torino, Italy. In this prospective double-masked randomized clinical trial, patients had phacoemulsification alone (control group) or phacoemulsification with iStent implantation (combined group). Primary outcomes were intraocular pressure (IOP) and reduction in medication use over 15 months and IOP after a 1-month washout of ocular hypotensive agents (ie, 16 months postoperatively). The baseline IOP was similar between groups (combined group: 17.9 mm Hg +/- 2.6 [SD]; control group: 17.3 +/- 3.0 mm Hg) (P = .512). Three patients in the control group were lost to follow-up. The mean IOP was 14.8 +/- 1.2 mm Hg in the combined group and 15.7 +/- 1.1 mm Hg in the control group at 15 months and 16.6 +/- 3.1 mm Hg and 19.2 +/- 3.5 mm Hg, respectively, after washout; the IOP was statistically significantly lower in the combined group than in the control group at both time points (P = .031 and P = .042, respectively). At 15 months, the mean number of medications was lower in the combined group than in the control group (0.4 +/- 0.7 and 1.3 +/- 1.0, respectively; P = .007), as was the proportion of patients on ocular hypotensive medication (33% and 76%, respectively). Phacoemulsification with stent implantation was more effective in controlling IOP than phacoemulsification alone; the safety profiles were similar. Copyright 2010 ASCRS and ESCRS. Published by Elsevier Inc. All rights reserved.

          Related collections

          Author and article information

          Journal
          Journal of Cataract & Refractive Surgery
          Journal of Cataract & Refractive Surgery
          Elsevier BV
          08863350
          March 2010
          March 2010
          : 36
          : 3
          : 407-412
          Article
          10.1016/j.jcrs.2009.10.031
          20202537
          c4fc5332-b3c9-4f63-9608-f6b51e2ed702
          © 2010

          https://www.elsevier.com/tdm/userlicense/1.0/

          History

          Comments

          Comment on this article