39
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Usefulness of Non-Magnifying Narrow-Band Imaging in Screening of Early Esophageal Squamous Cell Carcinoma: A Prospective Comparative Study Using Propensity Score Matching

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          OBJECTIVES:

          The usefulness of non-magnifying endoscopy with narrow-band imaging (NBI; NM-NBI) in the screening of early esophageal squamous cell carcinoma (SCC) and high-grade intraepithelial neoplasia (HGIN) remains unclear. Here, we aimed to compare NM-NBI and chromoendoscopy with iodine staining (CE-Iodine) in terms of the diagnostic performance, and to evaluate the usefulness of NM-NBI in detecting early esophageal SCC.

          METHODS:

          We prospectively enrolled 202 consecutive patients (male/female=180/22; median age, 67 years) with high-risk factors for esophageal SCC. All patients received endoscopic examination with NM-NBI and CE-Iodine to screen for early esophageal SCC or HGIN. We conducted the examinations sequentially, and calculated the accuracy, sensitivity, and specificity through a per-lesion-based analysis. A propensity score matching analysis was performed to reduce the effects of selection bias, and we compared the respective outcomes according to NM-NBI and CE-Iodine after matching.

          RESULTS:

          The accuracy, sensitivity, and specificity of NM-NBI were 77.0, 88.3, and 75.2%, respectively, and those for unstained areas by CE-Iodine were 68.0, 94.2, and 64.0, respectively. The accuracy and specificity of NM-NBI were superior to those of CE-Iodine ( P=0.03 and P=0.01, respectively). However, the sensitivity did not significantly differ between NM-NBI and CE-Iodine ( P=0.67). The accuracy and specificity of NM-NBI before matching were superior to those of CE-Iodine after matching ( P=0.04 and P=0.03).

          CONCLUSIONS:

          NM-NBI was useful and reliable for the diagnosis of esophageal SCC and can be a promising screening strategy for early esophageal SCC.

          Related collections

          Most cited references27

          • Record: found
          • Abstract: found
          • Article: not found

          Cancer Statistics, 2008

          Each year, the American Cancer Society estimates the number of new cancer cases and deaths expected in the United States in the current year and compiles the most recent data on cancer incidence, mortality, and survival based on incidence data from the National Cancer Institute, Centers for Disease Control and Prevention, and the North American Association of Central Cancer Registries and mortality data from the National Center for Health Statistics. Incidence and death rates are age-standardized to the 2000 US standard million population. A total of 1,437,180 new cancer cases and 565,650 deaths from cancer are projected to occur in the United States in 2008. Notable trends in cancer incidence and mortality include stabilization of incidence rates for all cancer sites combined in men from 1995 through 2004 and in women from 1999 through 2004 and a continued decrease in the cancer death rate since 1990 in men and since 1991 in women. Overall cancer death rates in 2004 compared with 1990 in men and 1991 in women decreased by 18.4% and 10.5%, respectively, resulting in the avoidance of over a half million deaths from cancer during this time interval. This report also examines cancer incidence, mortality, and survival by site, sex, race/ethnicity, education, geographic area, and calendar year, as well as the proportionate contribution of selected sites to the overall trends. Although much progress has been made in reducing mortality rates, stabilizing incidence rates, and improving survival, cancer still accounts for more deaths than heart disease in persons under age 85 years. Further progress can be accelerated by supporting new discoveries and by applying existing cancer control knowledge across all segments of the population.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Early detection of superficial squamous cell carcinoma in the head and neck region and esophagus by narrow band imaging: a multicenter randomized controlled trial.

            Most of the esophageal squamous cell carcinomas (ESCCs) and cancers of the head and neck (H&N) region are diagnosed at later stages. To achieve better survival, early detection is necessary. We compared the real-time diagnostic yield of superficial cancer in these regions between conventional white light imaging (WLI) and narrow band imaging (NBI) in high-risk patients. In a multicenter, prospective, randomized controlled trial, 320 patients with ESCC were randomly assigned to primary WLI followed by NBI (n = 162) or primary NBI followed by WLI (n = 158) in a back-to-back fashion. The primary aim was to compare the real-time detection rates of superficial cancer in the H&N region and the esophagus between WLI and NBI. The secondary aim was to evaluate the diagnostic accuracy of these techniques. NBI detected superficial cancer more frequently than did WLI in both the H&N region and the esophagus (100% v 8%, P < .001; 97% v 55%, P < .001, respectively). The sensitivity of NBI for diagnosis of superficial cancer was 100% and 97.2% in the H&N region and the esophagus, respectively. The accuracy of NBI for diagnosis of superficial cancer was 86.7% and 88.9% in these regions, respectively. The sensitivity and accuracy were significantly higher using NBI than WLI in both regions (P < .001 and P = .02 for the H&N region; P < .001 for both measures for the esophagus, respectively). NBI could be the standard examination for the early detection of superficial cancer in the H&N region and the esophagus.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The bias due to incomplete matching.

              Observational studies comparing groups of treated and control units are often used to estimate the effects caused by treatments. Matching is a method for sampling a large reservoir of potential controls to produce a control group of modest size that is ostensibly similar to the treated group. In practice, there is a trade-off between the desires to find matches for all treated units and to obtain matched treated-control pairs that are extremely similar to each other. We derive expressions for the bias in the average matched pair difference due to the failure to match all treated units--incomplete matching, and the failure to obtain exact matches--inexact matching. A practical example shows that the bias due to incomplete matching can be severe, and moreover, can be avoided entirely by using an appropriate multivariate nearest available matching algorithm, which, in the example, leaves only a small residual bias due to inexact matching.
                Bookmark

                Author and article information

                Journal
                Am J Gastroenterol
                Am. J. Gastroenterol
                The American Journal of Gastroenterology
                Nature Publishing Group
                0002-9270
                1572-0241
                June 2014
                22 April 2014
                : 109
                : 6
                : 845-854
                Affiliations
                [1 ]Department of Gastroenterology, Osaka City University Graduate School of Medicine , Osaka, Japan
                [2 ]Department of Surgical Oncology, Osaka City University Graduate School of Medicine , Osaka, Japan
                [3 ]Department of Otolaryngology and Head & Neck Surgery, Osaka City University Graduate School of Medicine , Osaka, Japan
                [4 ]Machida Gastrointestinal Hospital , Osaka, Japan
                [5 ]Department of Gastroenterology, Minamiosaka Hospital , Osaka, Japan
                [6 ]Department of Gastroenterology, Ohno Memorial Hospital , Osaka, Japan
                Author notes
                [* ]Department of Gastroenterology, Osaka City University Graduate School of Medicine , 1-4-3, Asahimachi, Abeno-ku, Osaka 545-8585, Japan. E-mail: tomy@ 123456med.osaka-cu.ac.jp
                Article
                ajg201494
                10.1038/ajg.2014.94
                4050526
                24751580
                c54dba10-f06f-46a5-97a8-7e1ed7307054
                Copyright © 2014 American College of Gastroenterology

                This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivs 3.0 Unported License. To view a copy of this license, visit http://creativecommons.org/licenses/by-nc-nd/3.0/

                History
                : 18 July 2013
                : 12 March 2014
                Categories
                Esophagus

                Gastroenterology & Hepatology
                Gastroenterology & Hepatology

                Comments

                Comment on this article