          Abstract

          Implementations of Lab-on-a-Chip technologies for in-situ analysis of small model organisms and embryos (both invertebrate and vertebrate) are attracting an increasing interest. A significant hurdle to widespread applications of microfluidic and millifluidic devices for in-situ analysis of small model organisms is the access to expensive clean room facilities and complex microfabrication technologies. Furthermore, these resources require significant investments and engineering know-how. For example, poly(dimethylsiloxane) soft lithography is still largely unattainable to the gross majority of biomedical laboratories willing to pursue development of chip-based platforms. They often turn instead to readily available but inferior classical solutions. We refer to this phenomenon as workshop-to-bench gap of bioengineering science. To tackle the above issues, we examined the capabilities of commercially available Multi-Jet Modelling (MJM) and Stereolithography (SLA) systems for low volume fabrication of optical-grade millifluidic devices designed for culture and biotests performed on millimetre-sized specimens such as zebrafish embryos. The selected 3D printing technologies spanned a range from affordable personal desktop systems to high-end professional printers. The main motivation of our work was to pave the way for off-the-shelf and user-friendly 3D printing methods in order to rapidly and inexpensively build optical-grade millifluidic devices for customized studies on small model organisms. Compared with other rapid prototyping technologies such as soft lithography and infrared laser micromachining in poly(methyl methacrylate), we demonstrate that selected SLA technologies can achieve user-friendly and rapid production of prototypes, superior feature reproduction quality, and comparable levels of optical transparency. A caution need to be, however, exercised as majority of tested SLA and MJM resins were found toxic and caused significant developmental abnormalities in zebrafish embryos. Taken together, our data demonstrate that SLA technologies can be used for rapid and accurate production of devices for biomedical research. However, polymer biotoxicity needs to be carefully evaluated.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          Microfluidic devices fabricated in poly(dimethylsiloxane) for biological studies.

          This review describes microfluidic systems in poly(dimethylsiloxane) (PDMS) for biological studies. Properties of PDMS that make it a suitable platform for miniaturized biological studies, techniques for fabricating PDMS microstructures, and methods for controlling fluid flow in microchannels are discussed. Biological procedures that have been miniaturized into PDMS-based microdevices include immunoassays, separation of proteins and DNA, sorting and manipulation of cells, studies of cells in microchannels exposed to laminar flows of fluids, and large-scale, combinatorial screening. The review emphasizes the advantages of miniaturization for biological analysis, such as efficiency of the device and special insights into cell biology.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Configurable 3D-Printed millifluidic and microfluidic 'lab on a chip' reactionware devices.

            We utilise 3D design and 3D printing techniques to fabricate a number of miniaturised fluidic 'reactionware' devices for chemical syntheses in just a few hours, using inexpensive materials producing reliable and robust reactors. Both two and three inlet reactors could be assembled, as well as one-inlet devices with reactant 'silos' allowing the introduction of reactants during the fabrication process of the device. To demonstrate the utility and versatility of these devices organic (reductive amination and alkylation reactions), inorganic (large polyoxometalate synthesis) and materials (gold nanoparticle synthesis) processes were efficiently carried out in the printed devices.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Cost-effective three-dimensional printing of visibly transparent microchips within minutes.

              One-step fabrication of transparent three-dimensional (3D) microfluidic to millifluidic devices was demonstrated using a commercial 3D printer costing $2300 with 500 mL of clear resin for $138. It employs dynamic mask projection stereolithography, allowing fast concept-to-chip time. The fully automated system allows fabrication of models of up to 43 mm × 27 mm × 180 mm (x × y × z) at printing speeds of 20 mm/h in height regardless of the design complexity. The minimal cross sectional area of 250 μm was achieved for monolithic microchannels and 200 μm for positive structures (templates for soft lithography). The colorless resin's good light transmittance (>60% transmission at wavelengths of >430 nm) allows for on-chip optical detection, while the electrically insulating material allows electrophoretic separations. To demonstrate its applicability in microfluidics, the printer was used for the fabrication of a micromixer, a gradient generator, a droplet extractor, and a device for isotachophoresis. The mixing and gradient formation units were incorporated into a device for analysis of nitrate in tap water with standard addition as a single run and multiple depth detection cells to provide an extended linear range.
                Bookmark

                Author and article information

                Journal
                Biomicrofluidics
                Biomicrofluidics
                1932-1058
                1932-1058
                Jul 2015
                : 9
                : 4
                Affiliations
                [1 ] The BioMEMS Research Group, School of Applied Sciences, RMIT University , Melbourne, Victoria 3083, Australia.
                [2 ] School of Engineering, University of Glasgow , Glasgow G12 8QQ, United Kingdom.
                [3 ] Australian Regenerative Medicine Institute, Monash University , Clayton, Victoria 3800, Australia.
                Article
                1.4927379 009504BMF
                10.1063/1.4927379
                4514717
                26339325
                c8715b0a-e53b-4737-9e02-94a500888a3f
                History

                Comments

                Comment on this article

                scite_

                Similar content190

                Cited by19

                Most referenced authors660