11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Investigation of the choroidal thickness in patients with hypothyroidism

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose:

          The effect of hypothyroidism on the choroidal thickness (CT) was investigated in patients with subclinical hypothyroidism and overt hypothyroidism, and biochemically and clinically euthyroid patients receiving levothyroxine treatment. The patients were compared with healthy subjects.

          Materials and Methods:

          One eye of 71 hypothyroid and 22 healthy subjects between 20 and 40 years of age were included in this study. CT measurements were taken at the fovea and at 2 points that were 1500 μm nasal and temporal to the fovea using spectral-domain optical coherence tomography. Independent sample t-test's and was used for statistical analysis of the data.

          Results:

          The CT was significantly thicker in hypothyroid patients compared to healthy subjects ( P values were 0.013 for subfoveal, 0.015 for temporal and 0.020 for nasal segments). The intraocular pressure (IOP) and body mass index (BMI) were also significantly higher in hypothyroid patients ( P values were 0.021 and 0.003, respectively). There was not a statistically significant difference in the BMI and IOP measurements between healthy subjects and euthyroid patients ( P > 0.05). However, there was a statistically significant difference in the subfoveal, temporal and nasal CT measurements between healthy subjects and euthyroid patients ( P values were 0.006, 0.031 and 0.013, respectively).

          Conclusions:

          All subgroups of hypothyroid patients had thicker CT compared to healthy subjects. Euthyroid patients receiving levothyroxine treatment had lower IOP, BMI levels, and serum lipid levels than patients with subclinical hypothyroidism and overt hypothyroidism.

          Related collections

          Most cited references26

          • Record: found
          • Abstract: found
          • Article: not found

          A pilot study of enhanced depth imaging optical coherence tomography of the choroid in normal eyes.

          To measure macular choroidal thickness in normal eyes at different points using enhanced depth imaging (EDI) optical coherence tomography (OCT) and to evaluate the association of choroidal thickness and age. Retrospective, observational case series. EDI OCT images were obtained in patients without significant retinal or choroidal pathologic features. The images were obtained by positioning a spectral-domain OCT device close enough to the eye to acquire an inverted image. Seven sections were obtained within a 5 x 30-degree area centered at the fovea, with 100 scans averaged for each section. The choroid was measured from the outer border of the retinal pigment epithelium to the inner scleral border at 500-microm intervals of a horizontal section from 3 mm temporal to the fovea to 3 mm nasal to the fovea. Statistical analysis was performed to evaluate variations of choroidal thickness at each location and to correlate choroidal thickness and patient age. The mean age of the 30 patients (54 eyes) was 50.4 years (range, 19 to 85 years), and 14 patients (46.7%) were female. The choroid was thickest underneath the fovea (mean, 287 microm; standard deviation, +/- 76 microm). Choroidal thickness decreased rapidly in the nasal direction and averaged 145 microm (+/- 57 microm) at 3 mm nasal to the fovea. Increasing age was correlated significantly with decreasing choroidal thickness at all points measured. Regression analysis suggested that the subfoveal choroidal thickness decreased by 15.6 microm for each decade of life. Choroidal thickness seems to vary topographically within the posterior pole. The thickness of the choroid showed a negative correlation with age. The decrease in the thickness of the choroid may play a role in the pathophysiologic features of various age-related ocular conditions.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Enhanced depth imaging optical coherence tomography of the choroid in central serous chorioretinopathy.

            The purpose of the study was to evaluate the choroidal thickness in patients with central serous chorioretinopathy, a disease attributed to increased choroidal vascular hyperpermeability. Patients with central serous chorioretinopathy underwent enhanced depth imaging spectral-domain optical coherence tomography, which was obtained by positioning a spectral-domain optical coherence tomography device close enough to the eye to acquire an inverted image. Seven sections, each comprising 100 averaged scans, were obtained within a 5 degrees x 30 degrees rectangle to encompass the macula. The subfoveal choroidal thickness was measured from the outer border of the retinal pigment epithelium to the inner scleral border. The mean age of subjects undergoing enhanced depth imaging spectral-domain optical coherence tomography was 59.3 years (standard deviation, 15.8 years). Seventeen of 19 patients (89.5%) were men, and 12 (63.2%) patients had bilateral clinical disease. The choroidal thickness measured in 28 eligible eyes of the 19 patients was 505 microm (standard deviation, 124 microm), which was significantly greater than the choroidal thickness in normal eyes (P < or = 0.001). Enhanced depth imaging spectral-domain optical coherence tomography demonstrated a very thick choroid in patients with central serous chorioretinopathy. This finding provides additional evidence that central serous chorioretinopathy may be caused by increased hydrostatic pressure in the choroid.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Diurnal variation of choroidal thickness in normal, healthy subjects measured by spectral domain optical coherence tomography.

              To describe the pattern and magnitude of diurnal variation of choroidal thickness (CT), its relation to systemic and ocular factors, and to determine the intervisit reproducibility of diurnal patterns. A prospective study was conducted on 12 healthy volunteers who each underwent sequential ocular imaging on two separate days at five fixed, 2-hour time intervals. Spectral domain optical coherence tomography (OCT) with enhanced depth imaging and image tracking was performed using a standardized protocol. Choroidal and retinal thicknesses were independently assessed by two masked graders. CT diurnal variation was assessed using repeated-measures ANOVA. A significant diurnal variation in CT was observed, with mean maximum CT of 372.2 μm, minimum of 340.6 μm (P < 0.001), and mean diurnal amplitude of 33.7 μm. Retinal thickness (mean, 235.0 μm) did not exhibit significant diurnal variation (P = 0.621). The amplitude of CT variation was significantly greater for subjects with thicker morning baseline CT compared with those with thin choroids (43.1 vs. 10.5 μm, P < 0.001). There were significant correlations between amplitude of CT and age (P = 0.032), axial length (P < 0.001), and spherical equivalent (P < 0.001). The change in CT also correlated with change in systolic blood pressure (P = 0.031). Comparing CT on two different days, a similar diurnal pattern was observed, with no significant difference between corresponding measurements at the same time points (P = 0.180). There is significant diurnal variation of CT, with good intervisit reproducibility of diurnal patterns on two different days. The amplitude of variation varies with morning baseline CT, and is correlated with age, axial length, refractive error, and change in systolic blood pressure.
                Bookmark

                Author and article information

                Journal
                Indian J Ophthalmol
                Indian J Ophthalmol
                IJO
                Indian Journal of Ophthalmology
                Medknow Publications & Media Pvt Ltd (India )
                0301-4738
                1998-3689
                March 2015
                : 63
                : 3
                : 244-249
                Affiliations
                [1]Department of Ophthalmology, Faculty of Medicine, Abant Izzet Baysal University, Bolu, Turkey
                [1 ]Department of Internal Medicine, Faculty of Medicine, Abant Izzet Baysal University, Bolu, Turkey
                Author notes
                Correspondence to: Dr. Fatih Ulaş, Department of Ophthalmology, Faculty of Medicine, Abant Izzet Baysal University, 14280 Bolu, Turkey. E-mail: fatihu44@ 123456yahoo.com
                Article
                IJO-63-244
                10.4103/0301-4738.156976
                4448238
                25971170
                c94d0b7d-5555-41c9-b0d1-0f5880ec808a
                Copyright: © Indian Journal of Ophthalmology

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Noncommercial-Share Alike 3.0 Unported, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 16 October 2014
                : 05 March 2015
                Categories
                Original Article

                Ophthalmology & Optometry
                choroidal thickness,enhanced depth imaging,hypothyroidism,intraocular pressure,optical coherence tomography

                Comments

                Comment on this article