8
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Outcome of patients with nonischemic dilated cardiomyopathy and unexplained syncope treated with an implantable defibrillator

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The purpose of this study was to determine the outcome of patients with nonischemic dilated cardiomyopathy, unexplained syncope and a negative electrophysiology test who are treated with an implantable defibrillator. Patients with nonischemic cardiomyopathy and unexplained syncope may be at high risk for sudden cardiac death, and they are sometimes treated with an implantable defibrillator. This study prospectively determined the outcome of 14 consecutive patients who had a nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test and who underwent defibrillator implantation (Syncope Group). Nineteen consecutive patients with a nonischemic cardiomyopathy and a cardiac arrest who were treated with a defibrillator (Arrest Group) served as a control group. Seven of 14 patients (50%) in the Syncope Group received appropriate shocks for ventricular arrhythmias during a mean follow-up of 24+/-13 months, compared with 8 of 19 patients (42%) in the Arrest Group during a mean follow-up of 45+/-40 months (p = 0.1). The mean duration from device implantation until the first appropriate shock was 32+/-7 months (95% confidence interval [CI], 18 to 45 months) in the Syncope Group compared to 72+/-12 months (95% CI, 48 to 96 months) in the Arrest Group (p = 0.1). Among patients who received appropriate shocks, the mean time from defibrillator implantation to the first appropriate shock was 10+/-14 months in the Syncope Group, compared with 48+/-47 months in the Arrest Group (p = 0.06). Recurrent syncope was always associated with ventricular tachyarrhythmias. The high incidence of appropriate defibrillator shocks and the association of recurrent syncope with ventricular arrhythmias support the treatment of patients with nonischemic cardiomyopathy, unexplained syncope and a negative electrophysiology test with an implantable defibrillator.

          Related collections

          Author and article information

          Journal
          Journal of the American College of Cardiology
          Journal of the American College of Cardiology
          Elsevier BV
          07351097
          June 1999
          June 1999
          : 33
          : 7
          : 1964-1970
          Article
          10.1016/S0735-1097(99)00148-5
          10362200
          ca2321cc-02c9-4865-b6d7-e92f5514d7de
          © 1999

          https://www.elsevier.com/tdm/userlicense/1.0/

          https://www.elsevier.com/open-access/userlicense/1.0/

          History

          Comments

          Comment on this article

          scite_

          Similar content3,381

          Cited by8