      Effect of pupillary dilation on Haigis formula-calculated intraocular lens power measurement by using optical biometry

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Purpose

          The purpose of this study was to evaluate the effect of pupillary dilation on the Haigis formula-calculated intraocular lens (IOL) power and ocular biometry measurements by using IOLMaster ®.

          Methods

          A prospective study was performed for biometry measurements of 373 eyes of 192 healthy subjects using the IOLMaster at the outpatient department of King Chulalongkorn Memorial Hospital from February 2013 to July 2013. The axial length (AL), anterior chamber depth (ACD), keratometry (K), and IOL power were measured before and after 1% tropicamide eye drop instillation. The Haigis formula was used in the IOL power calculation with the predicted target to emmetropia. Each parameter was compared by a paired t-test prior to and after pupillary dilation. Bland–Altman plots were also used to determine the agreement between each parameter.

          Results

          The mean age of the subjects was 53.74±14.41 years (range 18–93 years). No differences in AL ( P=0.03), steepest K ( P=0.42), and flattest K ( P=0.41) were obtained from the IOLMaster after pupillary dilation. However, ACD and IOL power were significantly different postdilation ( P<0.01 and P<0.01, respectively). In ACD and IOL power measurements, the concordance rates were 93.03% and 97.05% within 95% limits of agreement (−0.48 to 0.26 mm and −1.09 to 0.88 D, respectively) in the Bland–Altman plots.

          Conclusion

          Biometry measurements in the cycloplegic stage should be considered in the IOL formulas that use parameters other than AL and K.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Comparison of immersion ultrasound biometry and partial coherence interferometry for intraocular lens calculation according to Haigis.

          The precision of intraocular lens (IOL) calculation is essentially determined by the accuracy of the measurement of axial length. In addition to classical ultrasound biometry, partial coherence interferometry serves as a new optical method for axial length determination. A functional prototype from Carl Zeiss Jena implementing this principle was compared with immersion ultrasound biometry in our laboratory. In 108 patients attending the biometry laboratory for planning of cataract surgery, axial lengths were additionally measured optically. Whereas surgical decisions were based on ultrasound data, we used postoperative refraction measurements to calculate retrospectively what results would have been obtained if optical axial length data had been used for IOL calculation. For the translation of optical to geometrical lengths, five different conversion formulas were used, among them the relation which is built into the Zeiss IOL-Master. IOL calculation was carried out according to Haigis with and without optimization of constants. On the basis of ultrasound immersion data from our Grieshaber Biometric System (GBS), postoperative refraction after implantation of a Rayner IOL type 755 U was predicted correctly within +/- 1 D in 85.7% and within +/- 2 D in 99% of all cases. An analogous result was achieved with optical axial length data after suitable transformation of optical path lengths into geometrical distances. Partial coherence interferometry is a noncontact, user- and patient-friendly method for axial length determination and IOL planning with an accuracy comparable to that of high-precision immersion ultrasound.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Calculation of intraocular lens power: a review.

            This review describes the principles and practices involved in the calculation of intraocular lens (IOL) power. The theories behind formulas for calculating IOL power are described, using regression and optical methods employing 'thin lens' and 'thick lens' models, as well as exact ray-tracing methods. Numerical examples are included to illustrate the points made. The paper emphasizes the importance of establishing an accurate estimation of corneal power as well as an accurate technique for the measurement of axial length and accurate methods of predicting postoperative anterior chamber depth (ACD). It is concluded that current improvements in diagnostic and surgical technology, combined with the latest generation IOL power formulas, make the calculation and selection of appropriate IOL power among the most effective tools in refractive surgery today.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Biometry and intraocular lens power calculation.

              Heightened patient expectations for precise postoperative refractive results have spurred the continued improvements in biometry and intraocular lens calculations. In order to meet these expectations, attention to proper patient selection, accurate keratometry and biometry, and appropriate intraocular lens power formula selection with optimized lens constants are required. The article reviews recent studies and advances in the field of biometry and intraocular lens power calculations. Several noncontact optical-based devices compare favorably, if not superiorly, to older ultrasonic biometric and keratometric techniques. With additional improvements in the internal acquisition algorithm, the new IOL Master software version 5 upgrade should lessen operator variability and further enhance signal acquisition. The modern Haigis-L and Holladay 2 formulas more accurately determine the position and the shape of the intraocular lens power prediction curve. Postoperative refractive results depend on the precision of multiple factors and measurements. The element with the highest variability and inaccuracy is, ultimately, going to determine the outcome. By understanding the advantages and limitations of the current technology, it is possible to consistently achieve highly accurate results.
                Bookmark

                Author and article information

                Journal
                Clin Ophthalmol
                Clin Ophthalmol
                Clinical Ophthalmology
                Clinical Ophthalmology (Auckland, N.Z.)
                Dove Medical Press
                1177-5467
                1177-5483
                2016
                27 July 2016
                : 10
                : 1405-1410
                Affiliations
                [1 ]Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society
                [2 ]Department of Ophthalmology, Faculty of Medicine, Chulalongkorn University, Bangkok
                [3 ]Department of Ophthalmology, Samut Prakan Hospital, Samut Prakan, Thailand
                [4 ]Department of International Health, Johns Hopkins Bloomberg School of Public Health, Baltimore, MD, USA
                Author notes
                Correspondence: Bharkbhum Khambhiphant, Department of Ophthalmology, King Chulalongkorn Memorial Hospital, Thai Red Cross Society, Bangkok 10330, Thailand, Tel +66 8 9811 1573, Fax +66 2 252 8290, Email bharkbhum@ 123456gmail.com
                Article
                opth-10-1405
                10.2147/OPTH.S109797
                4968869
                27555746
                cab39827-145c-4d77-863b-6fa8918f732a
                © 2016 Khambhiphant et al. This work is published and licensed by Dove Medical Press Limited

                The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License ( http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Clinical Trial Report

                Ophthalmology & Optometry
                haigis formula,intraocular lens,iolmaster,optical biometry,pupillary dilation