          Machine perfusion or cold storage in deceased-donor kidney transplantation.

          Static cold storage is generally used to preserve kidney allografts from deceased donors. Hypothermic machine perfusion may improve outcomes after transplantation, but few sufficiently powered prospective studies have addressed this possibility. In this international randomized, controlled trial, we randomly assigned one kidney from 336 consecutive deceased donors to machine perfusion and the other to cold storage. All 672 recipients were followed for 1 year. The primary end point was delayed graft function (requiring dialysis in the first week after transplantation). Secondary end points were the duration of delayed graft function, delayed graft function defined by the rate of the decrease in the serum creatinine level, primary nonfunction, the serum creatinine level and clearance, acute rejection, toxicity of the calcineurin inhibitor, the length of hospital stay, and allograft and patient survival. Machine perfusion significantly reduced the risk of delayed graft function. Delayed graft function developed in 70 patients in the machine-perfusion group versus 89 in the cold-storage group (adjusted odds ratio, 0.57; P=0.01). Machine perfusion also significantly improved the rate of the decrease in the serum creatinine level and reduced the duration of delayed graft function. Machine perfusion was associated with lower serum creatinine levels during the first 2 weeks after transplantation and a reduced risk of graft failure (hazard ratio, 0.52; P=0.03). One-year allograft survival was superior in the machine-perfusion group (94% vs. 90%, P=0.04). No significant differences were observed for the other secondary end points. No serious adverse events were directly attributable to machine perfusion. Hypothermic machine perfusion was associated with a reduced risk of delayed graft function and improved graft survival in the first year after transplantation. (Current Controlled Trials number, ISRCTN83876362.) 2009 Massachusetts Medical Society
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Each additional hour of cold ischemia time significantly increases the risk of graft failure and mortality following renal transplantation.

            Although cold ischemia time has been widely studied in renal transplantation area, there is no consensus on its precise relationship with the transplantation outcomes. To study this, we sampled data from 3839 adult recipients of a first heart-beating deceased donor kidney transplanted between 2000 and 2011 within the French observational multicentric prospective DIVAT cohort. A Cox model was used to assess the relationship between cold ischemia time and death-censored graft survival or patient survival by using piecewise log-linear function. There was a significant proportional increase in the risk of graft failure for each additional hour of cold ischemia time (hazard ratio, 1.013). As an example, a patient who received a kidney with a cold ischemia time of 30 h presented a risk of graft failure near 40% higher than a patient with a cold ischemia time of 6 h. Moreover, we found that the risk of death also proportionally increased for each additional hour of cold ischemia time (hazard ratio, 1.018). Thus, every additional hour of cold ischemia time must be taken into account in order to increase graft and patient survival. These findings are of practical clinical interest, as cold ischemia time is among one of the main modifiable pre-transplantation risk factors that can be minimized by improved management of the peri-transplantation period.
              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Machine perfusion or cold storage in deceased-donor kidney transplantation.

                Bookmark

                Author and article information

                Journal
                Transplantation
                Transplantation
                Ovid Technologies (Wolters Kluwer Health)
                0041-1337
                2018
                August 2018
                : 102
                : 8
                : 1344-1350
                Article
                10.1097/TP.0000000000002188
                29570164
                cd2d73dd-e006-4889-b63d-fe81b32fef94
                © 2018
                History

                Comments

                Comment on this article