      Corneal Endothelial Cell Density after Trabeculoplasty

      research-article
      ,
      Ophthalmologica
      S. Karger AG
      Trabeculoplasty, Corneal endothelium, Laser energy level, Specular microscopy

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Central corneal endothelial photographs were taken with a specular microscope. The cell density was calculated with a computerized image analyzer. No difference between the treated and control eyes could be found. The laser energy level delivered in trabeculoplasty seems to be too small to induce any permanent changes in the endothelial cells.

          Related collections

          Author and article information

          Journal
          OPH
          Ophthalmologica
          10.1159/issn.0030-3755
          Ophthalmologica
          S. Karger AG
          0030-3755
          1423-0267
          1988
          1988
          31 March 2010
          : 196
          : 4
          : 182-184
          Affiliations
          Eye Department, University Center Hospital of Kuopio, Finland
          Article
          309897 Ophthalmologica 1988;196:182–184
          10.1159/000309897
          3173984
          d037c420-7800-4df2-8b56-7a55235c7554
          © 1988 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          History
          : 02 November 1987
          : 11 November 1987
          Page count
          Pages: 3
          Categories
          Original Paper

          Vision sciences,Ophthalmology & Optometry,Pathology
          Trabeculoplasty,Laser energy level,Specular microscopy,Corneal endothelium