      Computed Tomographic Images and Three-Dimensional Expression of Crystalline Lens Findings from Multiple Slices of Scheimpflug Slit Images

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although the observation of lens changes in clinical examination has been made through a slit lamp microscope under dilated pupil, precise documentation and analysis of lens changes are presently possible through Scheimpflug photographic images. However, the methodology is still unsatisfactory because the image analysis is two dimensional. In order to overcome this disadvantage, the authors aimed at developing a new methodology for obtaining computed tomographic images of the lens. 60 Scheimpflug slit images of a cataractous human lens were taken by an anterior eye segment analysis system as digital data. After the locations of the whole slit images had been matched, reconstruction of the coronal section line images was performed utilizing extracted image information. The total number of reconstructed coronal section images in additional procedures of the image interpolation was 150. Computed tomography of the lens image was made from those 150 images. A whole lens figure was also demonstrated as a moving three dimensional image.

          Related collections

          Author and article information

          Journal
          ORE
          Ophthalmic Res
          10.1159/issn.0030-3747
          Ophthalmic Research
          S. Karger AG
          978-3-8055-6245-4
          978-3-318-01917-9
          0030-3747
          1423-0259
          1995
          1995
          11 December 2009
          : 27
          : Suppl 1
          : 94-99
          Affiliations
          Department of Ophthalmology, Kanazawa Medical University, Uchinada, Japan
          Article
          267851 Ophthalmic Res 1995;27:94–99
          10.1159/000267851
          8577469
          © 1995 S. Karger AG, Basel

          Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

          Page count
          Pages: 6
          Categories
          Contributions to Non-Invasive Investigation Techniques for the Anterior Eye Segment and the Lens