7
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Integration of the denoising, inpainting and local harmonic B(z) algorithm for MREIT imaging of intact animals.

      Physics in medicine and biology
      Algorithms, Animals, Dogs, Electric Impedance, Image Processing, Computer-Assisted, methods, Magnetic Resonance Imaging, Tomography

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Conductivity imaging based on the current-injection MRI technique has been developed in magnetic resonance electrical impedance tomography. Current injected through a pair of surface electrodes induces a magnetic flux density distribution inside an imaging object, which results in additional magnetic field inhomogeneity. We can extract phase changes related to the current injection and obtain an image of the induced magnetic flux density. Without rotating the object inside the bore, we can measure only one component B(z) of the magnetic flux density B = (B(x), B(y), B(z)). Based on a relation between the internal conductivity distribution and B(z) data subject to multiple current injections, one may reconstruct cross-sectional conductivity images. As the image reconstruction algorithm, we have been using the harmonic B(z) algorithm in numerous experimental studies. Performing conductivity imaging of intact animal and human subjects, we found technical difficulties that originated from the MR signal void phenomena in the local regions of bones, lungs and gas-filled tubular organs. Measured B(z) data inside such a problematic region contain an excessive amount of noise that deteriorates the conductivity image quality. In order to alleviate this technical problem, we applied hybrid methods incorporating ramp-preserving denoising, harmonic inpainting with isotropic diffusion and ROI imaging using the local harmonic B(z) algorithm. These methods allow us to produce conductivity images of intact animals with best achievable quality. We suggest guidelines to choose a hybrid method depending on the overall noise level and existence of distinct problematic regions of MR signal void.

          Related collections

          Author and article information

          Journal
          21098914
          10.1088/0031-9155/55/24/010

          Chemistry
          Algorithms,Animals,Dogs,Electric Impedance,Image Processing, Computer-Assisted,methods,Magnetic Resonance Imaging,Tomography