      Novel Calibration Algorithm for a Three-Axis Strapdown Magnetometer

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          A complete error calibration model with 12 independent parameters is established by analyzing the three-axis magnetometer error mechanism. The said model conforms to an ellipsoid restriction, the parameters of the ellipsoid equation are estimated, and the ellipsoid coefficient matrix is derived. However, the calibration matrix cannot be determined completely, as there are fewer ellipsoid parameters than calibration model parameters. Mathematically, the calibration matrix derived from the ellipsoid coefficient matrix by a different matrix decomposition method is not unique, and there exists an unknown rotation matrix R between them. This paper puts forward a constant intersection angle method (angles between the geomagnetic field and gravitational field are fixed) to estimate R. The Tikhonov method is adopted to solve the problem that rounding errors or other errors may seriously affect the calculation results of R when the condition number of the matrix is very large. The geomagnetic field vector and heading error are further corrected by R. The constant intersection angle method is convenient and practical, as it is free from any additional calibration procedure or coordinate transformation. In addition, the simulation experiment indicates that the heading error declines from ±1° calibrated by classical ellipsoid fitting to ±0.2° calibrated by a constant intersection angle method, and the signal-to-noise ratio is 50 dB. The actual experiment exhibits that the heading error is further corrected from ±0.8° calibrated by the classical ellipsoid fitting to ±0.3° calibrated by a constant intersection angle method.

          Related collections

          Most cited references34

          • Record: found
          • Abstract: not found
          • Article: not found

          Calibration of Strapdown Magnetometers in Magnetic Field Domain

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Scalar calibration of vector magnetometers

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Extension of a two-step calibration methodology to include nonorthogonal sensor axes

                Bookmark

                Author and article information

                Journal
                Sensors (Basel)
                Sensors (Basel)
                Sensors (Basel, Switzerland)
                Molecular Diversity Preservation International (MDPI)
                1424-8220
                May 2014
                14 May 2014
                : 14
                : 5
                : 8485-8504
                Affiliations
                [1 ] College of Automation, Beijing Union University, Beijing 100101, China
                [2 ] School of Automation and Electrical Engineering, University of Science and Technology Beijing, Beijing 100083, China; E-Mails: lxs@ 123456ustb.edu.cn (X.S.L.); zxjjianghan@ 123456163.com (X.J.Z.); feng_yibo@ 123456163.com (Y.B.F.)
                Author notes

                Author Contributions: Yan Xia Liu writes most of the paper. Xi Sheng Li designs the structure of the paper and help to revise the manuscript. Xiao Juan Zhang provides the experiment data. Yi Bo Feng corrects part of the English expression. All authors approve the final version of the manuscript.

                [* ] Author to whom correspondence should be addressed; E-Mail: yanxia.liu@ 123456163.com ; Tel.: +86-010-649-005-17.
                Article
                sensors-14-08485
                10.3390/s140508485
                4063011
                24831110
                d11382f3-75b8-4a6b-a3d2-735c673bb6d4
                © 2014 by the authors; licensee MDPI, Basel, Switzerland.

                This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license ( http://creativecommons.org/licenses/by/3.0/).

                History
                : 27 February 2014
                : 27 April 2014
                : 28 April 2014
                Categories
                Article

                Biomedical engineering
                constant intersection angle assumption,ellipsoid fitting,restricted least squares solution,rotation matrix

                Comments

                Comment on this article