12
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Rapid and real-time detection technologies for emerging viruses of biomedical importance

      research-article
      Journal of Biosciences
      Springer India
      Emerging viruses, LAMP, rapid detection, real-time PCR

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The development of technologies with rapid and sensitive detection capabilities and increased throughput have become crucial for responding to greater number threats posed by emerging and re-emerging viruses in the recent past. The conventional identification methods require time-consuming culturing, and/ or detection of antibodies, which are not very sensitive and specific. The recent advances in molecular biology techniques in the field of genomics and proteomics greatly facilitate the rapid identification with more accuracy. We have developed two real-time assays ie., SYBR green I based real time reverse transcription polymerase chain reaction (RT-PCR) and RT-loop-mediated isothermal amplification (LAMP) assay for rapid detection as well as typing of some of the emerging viruses of biomedical importance viz. dengue, Japanese encephalitis, chikungunya, west Nile, severe acute respiratory syndrome virus (SARS) etc. Both these techniques are capable of detection and differentiation as well as quantifying viral load with higher sensitivity, rapidity, specificity. One of the most important advantages of LAMP is its field applicability, without requirement of any sophisticated equipments. Both these assays have been extensively evaluated and validated with clinical samples of recent epidemics from different parts of India. The establishment of these real time molecular assays will certainly facilitate the rapid detection of viruses with high degree of precision and accuracy in future.

          Related collections

          Most cited references36

          • Record: found
          • Abstract: found
          • Article: not found

          Detection of loop-mediated isothermal amplification reaction by turbidity derived from magnesium pyrophosphate formation.

          The loop-mediated isothermal amplification (LAMP) is a novel nucleic acid amplification method that uses only one type of enzyme. One of the characteristics of the LAMP method is its ability to synthesize extremely large amount of DNA. Accordingly, a large amount of by-product, pyrophosphate ion, is produced, yielding white precipitate of magnesium pyrophosphate in the reaction mixture. Judging the presence or absence of this white precipitate allows easy distinction of whether nucleic acid was amplified by the LAMP method. Since an increase in the turbidity of the reaction mixture according to the production of precipitate correlates with the amount of DNA synthesized, real-time monitoring of the LAMP reaction was achieved by real-time measurement of turbidity. Copyright 2001 Academic Press.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Real-time PCR in virology.

            The use of the polymerase chain reaction (PCR) in molecular diagnostics has increased to the point where it is now accepted as the gold standard for detecting nucleic acids from a number of origins and it has become an essential tool in the research laboratory. Real-time PCR has engendered wider acceptance of the PCR due to its improved rapidity, sensitivity, reproducibility and the reduced risk of carry-over contamination. There are currently five main chemistries used for the detection of PCR product during real-time PCR. These are the DNA binding fluorophores, the 5' endonuclease, adjacent linear and hairpin oligoprobes and the self-fluorescing amplicons, which are described in detail. We also discuss factors that have restricted the development of multiplex real-time PCR as well as the role of real-time PCR in quantitating nucleic acids. Both amplification hardware and the fluorogenic detection chemistries have evolved rapidly as the understanding of real-time PCR has developed and this review aims to update the scientist on the current state of the art. We describe the background, advantages and limitations of real-time PCR and we review the literature as it applies to virus detection in the routine and research laboratory in order to focus on one of the many areas in which the application of real-time PCR has provided significant methodological benefits and improved patient outcomes. However, the technology discussed has been applied to other areas of microbiology as well as studies of gene expression and genetic disease.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Rapid and sensitive method using multiplex real-time PCR for diagnosis of infections by influenza a and influenza B viruses, respiratory syncytial virus, and parainfluenza viruses 1, 2, 3, and 4.

              Laboratory diagnosis of viral respiratory infections is generally performed by virus isolation in cell culture and immunofluorescent assays. Reverse transcriptase PCR is now recognized as a sensitive and specific alternative for detection of respiratory RNA viruses. A rapid real-time multiplex PCR assay was developed for the detection of influenza A and influenza B viruses, human respiratory syncytial virus (RSV), parainfluenza virus 1 (PIV1), PIV2, PIV3, and PIV4 in a two-tube multiplex reaction which used molecular beacons to discriminate the pathogens. A total of 358 respiratory samples taken over a 1-year period were analyzed by the multiplex assay. The incidence of respiratory viruses detected in these samples was 67 of 358 (19%) and 87 of 358 (24%) by culture and real-time PCR, respectively. Culture detected 3 influenza A virus, 2 influenza B virus, 57 RSV, 2 PIV1, and 2 PIV3 infections. All of these culture-positive samples and an additional 5 influenza A virus, 6 RSV, 2 PIV1, 1 PIV2, 1 PIV3, and 3 PIV4 infections were detected by the multiplex real-time PCR. The application of real-time PCR to clinical samples increases the sensitivity for respiratory viral diagnosis. In addition, results can be obtained within 6 h, which increases clinical relevance. Therefore, use of this real-time PCR assay would improve patient management and infection control.
                Bookmark

                Author and article information

                Contributors
                paridamm@rediffmail.com
                Journal
                J Biosci
                J. Biosci
                Journal of Biosciences
                Springer India (New Delhi )
                0250-5991
                0973-7138
                1 November 2008
                2008
                : 33
                : 4
                : 617-628
                Affiliations
                GRID grid.418940.0, ISNI 0000000418032027, Department of Virology, , Defence R & D Establishment, ; Gwalior, 474 002 India
                Article
                79
                10.1007/s12038-008-0079-7
                7090734
                19208986
                d2fa3ba6-8356-4bd5-80f1-6fdebcfdbb79
                © Indian Academy of Sciences 2008

                This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.

                History
                Categories
                Article
                Custom metadata
                © Indian Academy of Sciences 2008

                emerging viruses,lamp,rapid detection,real-time pcr
                emerging viruses, lamp, rapid detection, real-time pcr

                Comments

                Comment on this article