2
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: not found
      • Article: not found

      Ultrasonic colour flow imaging

      Physics in Medicine and Biology
      IOP Publishing

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Related collections

          Most cited references57

          • Record: found
          • Abstract: not found
          • Article: not found

          Real-Time Two-Dimensional Blood Flow Imaging Using an Autocorrelation Technique

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Angle Independent Ultrasonic Detection of Blood Flow

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Time domain formulation of pulse-Doppler ultrasound and blood velocity estimation by cross correlation.

              The Doppler effect is usually described as a frequency shift of the backscattered signals from moving targets with respect to the frequency transmitted. Recently, real-time blood flow imaging has become possible thanks to the development of a new velocity estimator based on phase-shift measurements of successive echoes. However, this method suffers from the well-known limitations of pulse-Doppler instruments. A new formulation is presented which describes the pulse-Doppler effect on the successive echoes from a cloud of moving targets as a progressive translation in time due to the displacement of the scatterers between two excitations. This approach allows us to generate efficiently computer-simulated data in order to evaluate accurately the various processing techniques. Furthermore, it leads to a novel class of velocity estimators in the time domain which measure the time shifts which are proportional to the local blood velocity. Among them, the cross correlation of the received rf signals turns out to be well suited. A local cross-correlation function is first calculated from a consecutive pair of range-gated echoes and the time shift is then determined by searching for the time position with the maximum correlation. The time-correlation technique is shown to provide accurate velocity profiles with broadband transducers. Moreover, the classical velocity limitation of pulse-Doppler is overcome because there is no ambiguity in measuring a time shift instead of a phase shift. These major advantages should make quantitative flow mapping possible and more reliable.
                Bookmark

                Author and article information

                Journal
                Physics in Medicine and Biology
                Phys. Med. Biol.
                IOP Publishing
                0031-9155
                1361-6560
                December 01 1994
                December 01 1994
                January 01 1999
                : 39
                : 12
                : 2113-2145
                Article
                10.1088/0031-9155/39/12/001
                d30380b8-25cc-4271-86db-f3bcfdb6c143
                © 1999
                History

                Comments

                Comment on this article