1
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Reference values of electrographic and cardiac ultrasound parameters in Russian healthy children and adolescents

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Between 2009 and 2013, a large cross-sectional study on the health consequences of the Chernobyl nuclear accident was performed in the contaminated and uncontaminated territories of the Bryansk Oblast (Russian Federation). The objective of this work was to confirm or refute a possible association between childhood cardiac arrhythmia and a chronic exposure to caesium-137. As part of this study, a large number of electrocardiographic and cardiac ultrasound parameters were collected from 18,152 children aged 2–18 years including 12,512 healthy ones not contaminated with caesium-137. It seemed therefore relevant for us to share in a second publication these medical data based on healthy and uncontaminated children with the scientific community because of the large quantities and the limited availability of such kind of data. In the present study, relating to electrocardiographic parameters, the measurements performed fully reflect the expected evolution of the paediatric electrocardiogram between 5 and 18 years of age. Thus, the median values were generally quite close to those available in the literature. In contrast, differences in the 2nd and 98th percentiles were notable and could be explained in particular by the type of equipment used, the number of subjects included in the study and racial disparities. As for echocardiographic parameters, the evolution of the measured values in age groups is consistent with what was expected considering factors such as growth. In comparison with other scientific studies that have investigated these echocardiographic parameters, some differences by age groups have been identified. The ethnic factor truly appears to be a relevant feature to consider. In view of the results, it appeared essential to the authors to approach the methodological conditions of the scientific studies already published on the topic to be truly comparable and thus to provide a reliable answer on a topic for which real expectations in terms of medical care are required.

          Related collections

          Most cited references28

          • Record: found
          • Abstract: not found
          • Article: not found

          Guidelines and standards for performance of a pediatric echocardiogram: a report from the Task Force of the Pediatric Council of the American Society of Echocardiography.

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            AN ANALYSIS OF THE TIME-RELATIONS OF ELECTROCARDIOGRAMS.

            H C Bazett (1997)
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Recommendations regarding quantitation in M-mode echocardiography: results of a survey of echocardiographic measurements.

              Four hundred M-mode echocardiographic surveys were distributed to determine interobserver variability in M-mode echocardiographic measurements. This was done with a view toward examining the need and determining the criteria for standardization of measurement. Each survey consisted of five M-mode echocardiograms with a calibration marker, measured by the survey participants anonymously. The echoes were judged of adequate quality for measurement of structures. Seventy-six of the 400 (19%) were returned, allowing comparison of interobserver variability as well as examination of the measurement criteria which were used. Mean measurements and percent uncertainty were derived for each structure for each criterion of measurement. For example, for the aorta, 33% of examiners measured the aorta as an outer/inner or leading edge dimension, and 20% measured it as an outer/outer dimension. The percent uncertainty for the measurement (1.97 SD divided by the mean) showed a mean of 13.8% for the 25 packets of five echoes measured using the former criteria and 24.2% using the latter criteria. For ventricular chamber and cavity measurements, almost one-half of the examiners used the peak of the QRS and one-half of the examiners used the onset of the QRS for determining end-diastole. Estimates of the percent of measurement uncertainty for the septum, posterior wall and left ventricular cavity dimension in this study were 10--25%. They were much higher (40--70%) for the right ventricular cavity and right ventricular anterior wall. The survey shows significant interobserver and interlaboratory variation in measurement when examining the same echoes and indicates a need for ongoing education, quality control and standardization of measurement criteria. Recommendations for new criteria for measurement of M-mode echocardiograms are offered.
                Bookmark

                Author and article information

                Contributors
                geraldine.landon@irsn.fr
                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group UK (London )
                2045-2322
                3 February 2021
                3 February 2021
                2021
                : 11
                : 2916
                Affiliations
                [1 ]GRID grid.418735.c, ISNI 0000 0001 1414 6236, Division of Health, , Institute for Radiological Protection and Nuclear Safety (IRSN), ; BP 17, 92262 Fontenay-aux-Roses cedex, France
                [2 ]GRID grid.411119.d, ISNI 0000 0000 8588 831X, Department of Cardiology, , Bichat Hospital (AP-HP), ; Paris, France
                [3 ]Department of Cardiology, Bryansk Diagnostic Center, Bryansk, Russia
                [4 ]GRID grid.418735.c, ISNI 0000 0001 1414 6236, European and International Affairs Department, , Institute for Radiological Protection and Nuclear Safety (IRSN), ; BP 17, 92262 Fontenay-aux-Roses cedex, France
                Article
                82314
                10.1038/s41598-021-82314-0
                7858601
                33536510
                d545e33d-9ab6-44b9-ba9a-0e26e9a6a498
                © The Author(s) 2021

                Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

                History
                : 7 April 2020
                : 4 January 2021
                Categories
                Article
                Custom metadata
                © The Author(s) 2021

                Uncategorized
                cardiology,medical research
                Uncategorized
                cardiology, medical research

                Comments

                Comment on this article