      Cardiac MR fingerprinting for T1 and T2 mapping in four heartbeats

      research-article
      1 , , 1 , 1 , 1 , 1 , 1 , 1 , 2 , 1
      Journal of Cardiovascular Magnetic Resonance
      BioMed Central
      19th Annual SCMR Scientific Sessions
      27-30 January 2016

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background MR Fingerprinting (MRF) (Ma et al, Nature, 2013) can potentially achieve shorter scan times than conventional mapping by exploiting flexible sequence parameters. Cardiac MRF has been reported for single-slice mapping of T1 and T2 in sixteen heartbeats (Hamilton et al, Proc ISMRM, 2015). Here the scan duration is reduced to four heartbeats using an iterative multi-scale denoising pattern recognition (Pierre et al, Magn Reson Med, 2015). Methods The MRF scan is acquired during a breathhold and uses ECG triggering. Every heartbeat contains magnetization preparation and data readout stages. A non-selective inversion (TI = 21 ms) sensitizes the signal to T1 before the first excitation, and an MLEV composite T2-preparation is applied during the third (TE = 40 ms) and fourth (TE = 80 ms) heartbeats. The acquisition window employs a FISP readout with variable flip angles (4-15 deg), and the TR is minimized and held constant (5.1 ms) to maximize the number of images acquired each heartbeat. Data are sampled along a variable density spiral (TE = 1.4 ms) with 48 interleaves and a golden angle interleaf ordering. Each heartbeat, 48 images are collected in a 245 ms scan window and gridded using the NUFFT with acceleration factor R = 48. A dictionary of signal timecourses was calculated using a Bloch simulation, and quantitative maps were made using the denoising algorithm with 4 iterations (Gaussian weights of kmax*0.05, kmax*0.25, kmax*0.4, and no filtering on the final iteration). Eleven volunteers were imaged in short-axis orientation on a 3T Siemens Skyra with 30 coils. Scans were performed using MRF, the original 17-heartbeat MOLLI, and a 10-heartbeat T2-prepared bSSFP sequence (TE = 0, 25, and 55 ms). All scans used a 192 × 192 matrix, 1.6 × 1.6 × 8.0 mm3 spatial resolution, and 300 mm2 FoV. The conventional maps were fit by a nonlinear parameter estimation. Mean and standard deviations in T1 and T2 were computed over the entire myocardium and assessed using a Bland-Altman analysis. Additionally, in one volunteer the MRF scan was concatenated to map 4 slices during a 16-heartbeat breathhold, with each slice acquired in 4 consecutive heartbeats. Results Representative maps are in shown in Figure 1A, where the myocardial T1 and T2 from MRF are in good agreement with conventional maps. From the Bland-Altman plots (Figure 1B), the T1 measurements for all volunteers lie within the 95% limits of agreements (-97 ms, 51 ms) with bias -23 ms. Ten out of eleven T2 measurements are within the 95% limits of agreement (-8.9 ms, 5.9 ms) with bias -1.5 ms. Figure 2 displays MRF maps from 4 slices collected during a breathhold lasting 16 heartbeats (4 heartbeats per slice). Figure 1 1A: Maps of T1 and T2 acquired with 4-heartbeat MRF (left) compared with MOLLI and T2-prepared bSSFP (right). The mean and standard deviations for T1 and T2 within the myocardial wall are also presented. 1B: Bland-Altman plots comparing myocardial T1 between MRF and MOLLI and T2 between MRF and T2-prepared bSSFP in 11 volunteers. The 95% limits of agreement are indicated by red lines. Figure 2 MRF T1 and T2 maps from a volunteer acquired from four slices during a breathhold lasting sixteen heartbeats, where each slice was acquired in four consecutive heartbeats. The mean and standard deviations for T1 and T2 within the myocardial wall are also given. Conclusions Myocardial T1 and T2 maps can be acquired in 4 heartbeats using MRF with iterative denoising pattern recognition. The short scan time could be useful for patients who have difficulty with breathholds and could enable increased coverage if combined with multi-slice techniques.

          Related collections

          Author and article information

          Conference
          J Cardiovasc Magn Reson
          J Cardiovasc Magn Reson
          Journal of Cardiovascular Magnetic Resonance
          BioMed Central (London )
          1097-6647
          1532-429X
          27 January 2016
          27 January 2016
          2016
          : 18
          Issue : Suppl 1 Issue sponsor : Publication of this supplement was funded by the Society for Cardiovascular Magnetic Resonance.
          : W1
          Affiliations
          [1 ]grid.67105.350000000121643847Biomedical Engineering, Case Western Reserve University, Cleveland, OH USA
          [2 ]grid.241104.20000000404524020Radiology, University Hospitals, Cleveland, OH USA
          Article
          5299
          10.1186/1532-429X-18-S1-W1
          5032380
          d5ed315f-f3e9-4c09-87d4-7dc07cb76e1a
          © Hamilton et al. 2016

          This article is published under license to BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/4.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The Creative Commons Public Domain Dedication waiver ( http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.

          19th Annual SCMR Scientific Sessions
          Los Angeles, CA, USA
          27-30 January 2016
          History
          Categories
          Workshop Presentation
          Custom metadata
          © The Author(s) 2016

          Cardiovascular Medicine
          Cardiovascular Medicine

          Comments

          Comment on this article