      Ocular pulse amplitude in different types of glaucoma using dynamic contour tonometry: Diagnosis and follow-up of glaucoma

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The aim of the present study was to compare the ocular pulse amplitude (OPA) in patients with different types of glaucoma using dynamic contour tonometry (DCT), to evaluate ocular and systemic factors associated with the OPA and to verify whether OPA measured by DCT is an independent predictor for glaucoma diagnosis. A total of 217 eyes of 217 participants in the following five groups were included in this cross-sectional study: Chronic angle closure glaucoma (CACG), primary open angle glaucoma, normal tension glaucoma (NTG), suspected open angle glaucoma (SOAG) and normal control (NC). The following tests were simultaneously performed during a single visit: Intra-ocular pressure (IOP), OPA, cup-to-disk (C/D) ratio, mean damage (MD) and loss variance (LV). OPAs were compared in each group. The association between OPA and IOP, age, C/D ratio, MD and LV was detected. OPA analysis prior to and after trabeculectomy was also performed to assess its prognostic value. Among the 217 individuals, the OPA was consistent with the IOP, both measured by DCT, along with the MD and LV. Patients with CACG and SOAG had higher OPA values than those with NTG and normal controls. Compared with patients aged >30 years, the OPA was significantly lower in younger patients, while they may not have been affected by different C/D ratios. After trabeculectomy, the OPA had significantly decreased compared with the values prior to surgery. In conclusion, the present study showed that the OPA is correlated with the IOP determined by DCT. CACG and SOAG patients had higher OPA values than patients with other types of glaucoma. OPA measured by DCT may be a predictor for glaucoma diagnosis and prognosis.

          Related collections

          Most cited references17

          • Record: found
          • Abstract: found
          • Article: not found

          Corneal structure and biomechanics: impact on the diagnosis and management of glaucoma.

          Highlights recent studies relating to the impact of corneal structure and biomechanical properties on glaucoma evaluation and management. Central corneal thickness has been shown to play a role in the interpretation of intraocular pressure. Central corneal thickness has also been suggested as a glaucoma risk factor. The potential role of other corneal factors, such as stromal makeup, in the accurate measurement of intraocular pressure and the assessment of glaucoma risk remains to be determined. Improved understanding of central corneal thickness and corneal biomechanical properties may someday lead to a better understanding of glaucoma risk and its assessment.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Correlation between intraocular pressure, central corneal thickness, stage of glaucoma, and demographic patient data: prospective analysis of biophysical parameters in tertiary glaucoma practice populations.

            To determine the correlation of central corneal thickness (CCT) to Goldmann applanation tonometry (GAT) and dynamic contour tonometry (DCT, PASCAL), and to glaucoma stage as assessed by cup-to-disc ratio (CDR). Prospective, cross-sectional tricenter observation study. From three glaucoma specialty practices a sample of 406 independent eyes was included. After ultrasound pachymetry, intraocular pressure was measured using PASCAL and Goldmann applanation tonometry and cup-to-disc ration was reassessed. Demographic data were included in the multivariate analysis. Mean corneal thickness was 540 microm. African Americans and normal-tension glaucoma patients showed the lowest values (518 microm and 522 microm, respectively). These values were significantly thinner than the central corneal thickness of Caucasians (549 microm) and ocular hypertensives (564 microm). Intraocular pressure assessed by Goldmann applanation tonometry shows a significant correlation with central corneal thickness (r = 0.068, P < 0.001), whereas PASCAL is not significantly associated with central corneal thickness (r < 0.001, P = 0.997). Increased IOP is significantly correlated with large ocular pulse amplitudes (r = 0.13, P < 0.001), which is predominantly seen in ocular hypertensives. A significant negative correlation was detected between cup-to-disc ratio and central corneal thickness (r = 0.102, P < 0.001). Glaucoma patients with thin central corneal thickness are more likely to be found at an advanced stage of the disease and among those with normal-tension glaucoma and black African ancestry. Underestimation of intraocular pressure by Goldmann applanation tonometry could be one causative factor.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Dynamic contour tonometry: principle and use.

              Interindividual variability of central corneal thickness has been found to be a source of error for conventional Goldmann applanation tonometry. The dynamic contour tonometer represents a potentially new technology for non-invasive and direct intraocular pressure (IOP) measurement, and has been proposed to accurately measure the true IOP irrespective of the corneal thickness. It is based on the principle that when the tip of the device exactly matches the contour of the cornea, the pressure measured by a transducer placed on its tip is an accurate indicator of the true IOP. This device is also capable of measuring the ocular pulse amplitude, a variable that has controversial significance in the diagnosis and management of glaucoma. Even though this technique seems to be very promising, further studies are required to conclusively determine the effectiveness of the dynamic contour tonometer in patients having an abnormal or irregular corneal contour.
                Bookmark

                Author and article information

                Journal
                Exp Ther Med
                Exp Ther Med
                ETM
                Experimental and Therapeutic Medicine
                D.A. Spandidos
                1792-0981
                1792-1015
                November 2017
                30 August 2017
                30 August 2017
                : 14
                : 5
                : 4148-4152
                Affiliations
                [1 ]Department of Ophthalmology, Wuxi Second People's Hospital of Nanjing Medical University, Wuxi, Jiangsu 214000, P.R. China
                [2 ]Department of Ophthalmology, Zhongda Hospital, Medical School of Southeast University, Nanjing, Jiangsu 210009, P.R. China
                [3 ]Department of Ophthalmology, Xiangya No. 2 Hospital Affiliated to Central South University, Changsha, Hunan 410008, P.R. China
                Author notes
                Correspondence to: Professor Zhifeng Wu, Department of Ophthalmology, Wuxi Second People's Hospital of Nanjing Medical University, 68 Zhongshan Road, Wuxi, Jiangsu 214000, P.R. China, E-mail: 569562916@ 123456qq.com
                [*]

                Contributed equally

                Article
                ETM-0-0-5074
                10.3892/etm.2017.5074
                5658696
                d674c510-6b5d-4cf4-ad54-3f5433f1b990
                Copyright: © Cheng et al.

                This is an open access article distributed under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made.

                History
                : 12 May 2016
                : 24 March 2017
                Categories
                Articles

                Medicine
                ocular pulse amplitude,dynamic contour tonometry,intraocular pressure,glaucoma
                Medicine
                ocular pulse amplitude, dynamic contour tonometry, intraocular pressure, glaucoma

                Comments

                Comment on this article