4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Transseptal puncture by CTP-2 method: Results from cardiac computed tomography analysis and clinical application

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The current used parameters for transseptal puncture (TSP) under fluoroscopic guidance is from left atriography and need to be verified by precise anatomic measurement. From February 2009 to July 2013, consecutive patients who received computed tomography (CT) were included. Landmarks and parameters were preliminary studied by right atriography, and further evaluated on the CT images of 1001 patients. A method (CTP-2) was proposed for guiding TSP. In right anterior oblique 45° view, the CTP-2 method was defined by points C, T, and P, and 2 areas: point C is in coronary sinus; point T is at a distance of dCT (usually 1.5 ± 0.2 vertebral height) over point C; then point P, the optimal puncture site, was located at 0.5 ± 0.2 vertebral body height posterior to point T; puncture should avoid the aortic root area and the rear triangle area; the aortic root area could be negatively revealed by right atriography at the orifice of inferior vena cava, and the rear triangle area is demarcated by points C, C′, and T′ (C′ and T′ are 2 points horizontally posterior to, and at dCT away from points C and T, respectively). The initial application of CTP-2 in 2820 patients showed that it might be helpful in reducing the need of left atriography and the possibility of cardiac perforation.

          Related collections

          Most cited references18

          • Record: found
          • Abstract: found
          • Article: not found

          Trans-septal catheterization in the electrophysiology laboratory: data from a multicenter survey spanning 12 years.

          We report the data from the Italian Survey on trans-septal catheterization (TSP-C) for catheter ablation of arrhythmias in the left heart that covered 2003 and previous years. Over the last decade the use of TSP-C in the electrophysiology laboratory has greatly increased. Recent data on number of procedures, accomplishment rate, and complications related to this procedure are lacking in a large cohort of patients. Thirty-three centers participated in the survey. The data collected retrospectively for 2003 included the number of procedures, indications, methods, and the number and reason for unaccomplished cases along with complications. Retrospective data collected for previous years included the annual number of procedures and cumulative data concerning indications, accomplishments, and complications. Since 1992, 5,520 TSP-C procedures were used in arrhythmia ablation, with the peak increase in the use occurring in 2001. Trans-septal catheterization was performed for atrial fibrillation (AF) ablation in 78.3% of the procedures in 2003. The electrophysiologist independently performed the procedure in 29 of 33 centers. Trans-septal catheterization was successfully performed in 99.1% of the cases; the main reason for TSP-C not being performed was related to fossa ovalis/atrial septum anatomy. Complications were low both in 2003 and in the previous years (0.79% and 0.74%, respectively). Trans-septal catheterization in the electrophysiology laboratory is associated with a high success and low complication rate. The use of TSP-C has progressively increased over the last decade and is currently used primarily for AF ablation. Although possible, severe complications were rare.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Emerging applications for transseptal left heart catheterization old techniques for new procedures.

            Transseptal (TS) catheterization was introduced in 1959 as a strategy to directly measure left atrial (LA) pressure. Despite acceptable feasibility and safety, TS catheterization has been replaced by indirect measurements of LA pressure using the Swan-Ganz catheter. Today, TS puncture is rarely performed for diagnostic purposes but continues to be performed for procedures such as balloon mitral valvuloplasty, antegrade balloon aortic valvuloplasty, and ablation of arrhythmias in the LA. Thus, the "art" of TS puncture has been lost, except in centers that perform these procedures with regularity. Recently, there has been a renewed interest in the TS technique because of emerging therapeutic procedures for structural heart disease and atrial fibrillation ablation. Invasive cardiologists will have to refamiliarize themselves with the TS technique, newer TS devices, and advanced ultrasound imaging for guidance of the procedure.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Repeat transseptal catheterization after ablation for atrial fibrillation.

              A substantial number of patients require a second left atrial procedure after ablation for atrial fibrillation (AF), either for left atrial flutter or recurrent AF. The success and complication rates of repeat transseptal catheterization in these patients are unknown. The aim of this study was to determine the difficulty and/or success rates of repeat transseptal catheterization after left atrial ablation for AF. Consecutive patients undergoing repeat left atrial procedures after ablation for AF over a 1-year period were enrolled. Difficulties with, success rates, and complications of the first and second transseptal catheterizations were recorded. Sixteen patients underwent a repeat transseptal catheterization. Of the 4 in whom the first procedure was performed with an ablation catheter across a patent foramen ovale (PFO), 3 required a transseptal puncture for their repeat procedure. The remaining 12 underwent transseptal puncture without difficulty for their first procedure, and, despite the same operators for each patient, the repeat transseptal was noted to be difficult in 5. Of those 5, the transseptal puncture was unsuccessful due to increased interatrial septal thickness in 2 patients. One repeat transseptal attempt was aborted after posterior right atrial puncture with the transseptal needle occurred, attributed to distorted interatrial septal anatomy not observed prior to the first case. Compared with the first procedure, repeat transseptal catheterization after ablation for AF, whether initially performed across a PFO or via a transseptal puncture, is more difficult, less often successful, and potentially associated with more complications.
                Bookmark

                Author and article information

                Journal
                Medicine (Baltimore)
                Medicine (Baltimore)
                MEDI
                Medicine
                Wolters Kluwer Health
                0025-7974
                1536-5964
                August 2016
                26 August 2016
                : 95
                : 34
                : e4504
                Affiliations
                [a ]Department of Cardiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan, China
                [b ]St David's Medical Center, Austin, TX
                [c ]Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University
                [d ]Heart Center, Center for Atrial Fibrillation, Beijing Chao-Yang Hospital, Capital Medical University, Beijing
                [e ]Karamay Central Hospital, Karamay, Xinjiang, China.
                Author notes
                []Correspondence: Yan Wang and Dao Wen Wang, Department of Cardiology, Tongji Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430030, China (e-mail: newswangyantjh.tjmu.edu.cn [YW] and dwwang@ 123456tjh.tjmu.edu.cn [DWW] ).
                Article
                04504
                10.1097/MD.0000000000004504
                5400318
                27559952
                d6ab10b5-50f5-43d7-a679-b9fbde8af089
                Copyright © 2016 the Author(s). Published by Wolters Kluwer Health, Inc. All rights reserved.

                This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial License 4.0 (CCBY-NC), where it is permissible to download, share, remix, transform, and buildup the work provided it is properly cited. The work cannot be used commercially. http://creativecommons.org/licenses/by-nc/4.0

                History
                : 27 April 2016
                : 12 July 2016
                : 13 July 2016
                Categories
                3400
                Research Article
                Quality Improvement Study
                Custom metadata
                TRUE

                computed tomography,fluoroscopy,transseptal puncture

                Comments

                Comment on this article