17
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Clinical applications of intra-cardiac four-dimensional flow cardiovascular magnetic resonance: A systematic review

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Background

          Four-dimensional flow cardiovascular magnetic resonance (4D flow CMR) is an emerging non-invasive imaging technology used to visualise and quantify intra-cardiac blood flow. The aim of this systematic review is to assess the literature on the current clinical applications of intra-cardiac 4D flow CMR.

          Methods

          A systematic review was conducted to evaluate the literature on the intra-cardiac clinical applications of 4D flow CMR. Structured searches were carried out on Medline, EMBASE and the Cochrane Library in October 2016. A modified Critical Skills Appraisal Programme (CASP) tool was used to objectively assess and score the included studies. Studies were categorised as ‘highly clinically applicable’ for scores of 67–100%, ‘potentially clinically applicable’ for 34–66% and ‘less clinically applicable’ for 0–33%.

          Results

          Of the 1608 articles screened, 44 studies met eligibility for systematic review. The included literature consisted of 22 (50%) mechanistic studies, 18 (40.9%) pilot studies and 4 (9.1%) diagnostic studies. Based on the modified CASP tool, 27 (62%) studies were ‘highly clinically applicable’, 9 (20%) were ‘potentially clinically applicable’ and 8 (18%) were ‘less clinically applicable’.

          Conclusions

          There are many proposed methods for using 4D flow CMR to quantify intra-cardiac flow. The evidence base is mainly mechanistic, featuring single-centred designs. Larger, multi-centre studies are required to validate the proposed techniques and investigate the clinical advantages that 4D flow CMR offers over standard practices.

          PROSPERO = CRD42016051438.

          Related collections

          Most cited references48

          • Record: found
          • Abstract: not found
          • Article: not found

          Preferred reporting items for systematic reviews and meta-analyses: the PRISMA statement.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Mitral valve and tricuspid valve blood flow: accurate quantification with 3D velocity-encoded MR imaging with retrospective valve tracking.

            To validate flow assessment performed with three-dimensional (3D) three-directional velocity-encoded (VE) magnetic resonance (MR) imaging with retrospective valve tracking and to compare this modality with conventional two-dimensional (2D) one-directional VE MR imaging in healthy subjects and patients with regurgitation. Patients and volunteers gave informed consent, and local medical ethics committee approval was obtained. Patient data were selected retrospectively and randomly from a database of MR studies obtained between July 2006 and July 2007. The 3D three-directional VE MR images were first validated in vitro and compared with 2D one-directional VE MR images. Mitral valve (MV) and tricuspid valve (TV) flow were assessed in 10 volunteers without valve insufficiency and 20 patients with valve insufficiency, with aortic systolic stroke volume (ASSV) as the reference standard. Phantom validation showed less than 5% error for both techniques. In volunteers, 3D three-directional VE MR images showed no bias for MV or TV flow when compared with ASSV, whereas 2D one-directional VE MR images showed significant bias for MV flow (15% overestimation, P < .01). TV flow showed 25% overestimation; however, this was insignificant because of the high standard deviation. Correlation with ASSV was strong for 3D three-directional VE MR imaging (r = 0.96, P < .01 for MV flow; r = 0.88, P < .01 for TV flow) and between MV and TV flow (r = 0.91, P < .01); however, correlation was weaker for 2D one-directional VE MR imaging (r = 0.80, P < .01 for MV flow; r = 0.22, P = .55 for TV flow) and between MV flow and TV flow (r = 0.34, P = .34). In patients (mean regurgitation fractions of 13% and 10% for MV flow and TV flow, respectively), correlation between MV flow and TV flow for 3D three-directional VE MR imaging was strong (r = 0.97, P < .01). Use of 3D three-directional VE MR imaging enables accurate MV and TV flow quantification, even in patients with valve regurgitation. RSNA, 2008
              Bookmark
              • Record: found
              • Abstract: found
              • Article: found
              Is Open Access

              Four-dimensional blood flow-specific markers of LV dysfunction in dilated cardiomyopathy

              Aims Patients with mild heart failure (HF) who are clinically compensated may have normal left ventricular (LV) stroke volume (SV). Despite this, altered intra-ventricular flow patterns have been recognized in these subjects. We hypothesized that, compared with normal LVs, flow in myopathic LVs would demonstrate a smaller proportion of inflow volume passing directly to ejection and diminished the end-diastolic preservation of the inflow kinetic energy (KE). Methods and results In 10 patients with dilated cardiomyopathy (DCM) (49 ± 14 years, six females) and 10 healthy subjects (44 ± 17 years, four females), four-dimensional MRI velocity and morphological data were acquired. A previously validated method was used to separate the LV end-diastolic volume (EDV) into four flow components based on the blood's locations at the beginning and end of the cardiac cycle. KE was calculated over the cardiac cycle for each component. The EDV was larger (P = 0.021) and the ejection fraction smaller (P < 0.001) in DCM compared with healthy subjects; the SV was equivalent (DCM: 77 ± 19, healthy: 79 ± 16 mL). The proportion of the total LV inflow that passed directly to ejection was smaller in DCM (P = 0.000), but the end-diastolic KE/mL of the direct flow was not different in the two groups (NS). Conclusion Despite equivalent LVSVs, HF patients with mild LV remodelling demonstrate altered diastolic flow routes through the LV and impaired preservation of inflow KE at pre-systole compared with healthy subjects. These unique flow-specific changes in the flow route and energetics are detectable despite clinical compensation, and may prove useful as subclinical markers of LV dysfunction.
                Bookmark

                Author and article information

                Contributors
                Journal
                Int J Cardiol
                Int. J. Cardiol
                International Journal of Cardiology
                Elsevier
                0167-5273
                1874-1754
                15 December 2017
                15 December 2017
                : 249
                : 486-493
                Affiliations
                [a ]Division of Biomedical Imaging, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, Leeds, United Kingdom
                [b ]Leiden University Medical Centre, Leiden, The Netherlands
                Author notes
                [* ]Corresponding author at: Division of Biomedical Imaging, Leeds Institute of Cardiovascular and Metabolic Medicine (LICAMM), University of Leeds, LS2 9JT, United Kingdom.Division of Biomedical ImagingLeeds Institute of Cardiovascular and Metabolic Medicine (LICAMM)University of LeedsLS2 9JTUnited Kingdom S.Plein@ 123456leeds.ac.uk
                Article
                S0167-5273(17)32808-5
                10.1016/j.ijcard.2017.07.023
                5687937
                28964555
                d6ed4e4a-6bdf-4765-8a2c-89fcfa23c9e9
                © 2017 The Authors

                This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

                History
                : 10 May 2017
                : 27 June 2017
                : 10 July 2017
                Categories
                Article

                Cardiovascular Medicine
                intra-cardiac,systematic review,four-dimensional,4d flow cmr,4d flow mri,cardiovascular magnetic resonance

                Comments

                Comment on this article