48
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Animal Experimental Study of the Fully Biodegradable Atrial Septal Defect (ASD) Occluder

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          This study was conducted to evaluate the feasibility, safety, biocompatibility, and degradation features of a fully biodegradable occluder for closure of atrial septal defect (ASD) in an acute canine model. The ASD was created in 20 healthy mongrel dogs by the brockenbrough needle, and the fully biodegradable occluders were implanted by self-made delivery system. The success rate and complications were observed. Acute ASD models were successfully created in 18 dogs, and 16 occluders were successfully implanted in the ASD models. Animals were sacrificed at different times after procedure. The cardiac gross anatomy showed that all occluders were stable in the interatrial septum, no vegetation or thrombus formation was observed on the surface of all occluders. They were embedded into endogenous host tissue gradually at 12-week follow-up. Different periods of pathological observations suggested that the occluders degraded gradually over about 24 weeks and essentially became an integral part of the septum. Transcatheter closure of ASD in acute canine model using the fully biodegradable ASD occluder has the potential of a high successful rate of technique, excellent biocompatibility, and fewer complications with adequate, immediate, and short-term results.

          Related collections

          Most cited references32

          • Record: found
          • Abstract: found
          • Article: not found

          Incidence and clinical course of thrombus formation on atrial septal defect and patient foramen ovale closure devices in 1,000 consecutive patients.

          The purpose of this study was to investigate the incidence, morphology, and clinical course of thrombus formation after catheter closure of intra-atrial shunts. Post-procedure detailed information about thrombotic material on different devices for transcatheter closure is missing. A total of 1,000 consecutive patients were investigated after patent foramen ovale (PFO) (n = 593) or atrial septal defect (ASD) (n = 407) closure. Transesophageal echocardiography (TEE) was scheduled after four weeks and six months. Additional TEEs were performed as clinically indicated. Thrombus formation in the left atrium (n = 11), right atrium (n = 6), or both (n = 3) was found in 5 of the 407 (1.2%) ASD patients and in 15 of the 593 (2.5%) PFO patients (p = NS). The thrombus was diagnosed in 14 of 20 patients after four weeks and in 6 of 20 patients later on. The incidence was: 7.1% in the CardioSEAL device (NMT Medical, Boston, Massachusetts); 5.7% in the StarFLEX device (NMT Medical); 6.6% in the PFO-Star device (Applied Biometrics Inc., Burnsville, Minnesota); 3.6% in the ASDOS device (Dr. Ing, Osypka Corp., Grenzach-Wyhlen, Germany); 0.8% in the Helex device (W.L. Gore and Associates, Flagstaff, Arizona); and 0% in the Amplatzer device (AGA Medical Corp., Golden Valley, Minnesota). The difference between the Amplatzer device on one hand and the CardioSEAL device, the StarFLEX device, and the PFO-Star device on the other hand was significant (p < 0.05). A pre-thrombotic disorder as a possible cause of the thrombus was found in two PFO patients. Post-procedure atrial fibrillation (n = 4) and persistent atrial septal aneurysm (n = 4) had been found as significant predictors for thrombus formation (p < 0.05). In 17 of the 20 patients, the thrombus resolved under anticoagulation therapy with heparin or warfarin. In three patients, the thrombus was removed surgically. The incidence of thrombus formation on closure devices is low. The thrombus usually resolves under anticoagulation therapy.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Electrospun polydioxanone-elastin blends: potential for bioresorbable vascular grafts.

            An electrospun cardiovascular graft composed of polydioxanone (PDO) and elastin has been designed and fabricated with mechanical properties to more closely match those of native arterial tissue, while remaining conducive to tissue regeneration. PDO was chosen to provide mechanical integrity to the prosthetic, while elastin provides elasticity and bioactivity (to promote regeneration in vitro/in situ). It is the elastic nature of elastin that dominates the low-strain mechanical response of the vessel to blood flow and prevents pulsatile energy from being dissipated as heat. Uniaxial tensile and suture retention tests were performed on the electrospun grafts to demonstrate the similarities of the mechanical properties between the grafts and native vessel. Dynamic compliance measurements produced values that ranged from 1.2 to 5.6%/100 mmHg for a set of three different mean arterial pressures. Results showed the 50:50 ratio to closely mimic the compliance of native femoral artery, while grafts that contained less elastin exceeded the suture retention strength of native vessel. Preliminary cell culture studies showed the elastin-containing grafts to be bioactive as cells migrated through their full thickness within 7 days, but failed to migrate into pure PDO scaffolds. Electrospinning of the PDO and elastin-blended composite into a conduit for use as a small diameter vascular graft has extreme potential and warrants further investigation as it thus far compares favorably to native vessel.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Analysis of the US Food and Drug Administration Manufacturer and User Facility Device Experience database for adverse events involving Amplatzer septal occluder devices and comparison with the Society of Thoracic Surgery congenital cardiac surgery database.

              Amplatzer (AGA Medical Corporation, Plymouth, Minn) septal and vascular occluder devices have significantly altered the care of patients with congenital heart disease. The relative frequency and consequence of complications resulting from the attempted placement of such devices, however, have not been well assessed. The purpose of this study is to use large databases to assess the frequency and severity of such complications and compare them with those of surgical atrial septal defect closure. The US Food and Drug Administration Manufacturer and User Facility Device Experience database was quarried for all adverse events for Amplatzer septal occluder devices, which were categorized and analyzed with particular emphasis on management and outcome. The Society of Thoracic Surgery database was likewise quarried for the same data regarding atrial septal defect closures over a contemporaneous time period. By using a literature-derived denominator for total Amplatzer implant numbers, the results of the 2 therapies were compared. Since July 1, 2002, 223 adverse events in patients undergoing Amplatzer atrial septal defect closure were submitted to the Food and Drug Administration, resulting in 17 deaths (7.6%) and 152 surgical rescue operations (68.2%). Society of Thoracic Surgery data demonstrated 1537 primary operations with 2 deaths (0.13%) and 6 reoperations (0.39%). By extrapolating on published estimates of Amplatzer implantation to provide an implant denominator (n = 18,333), there was no difference between overall mortality for surgical (0.13%) and device closure (0.093%, P = .649). Rescue operation for device adverse events (0.83%) was 2.1 times more likely than reoperation for surgical closure (0.39%, P = .063). Mortality per adverse event was higher for device closure (7.6%) than for surgical closure (1.2%, P = .004), and the need for surgery per adverse event was higher for device closure (68.2%) than for surgical closure (3.6%, P < .001). The mortality for surgical management of a device adverse event (2.6%) was 20-fold higher than for primary elective atrial septal defect closure (0.13%, P < .0001). Overall crude mortality for device and surgical closure atrial septal defect closure is equivalent, and the need for subsequent operation (surgical rescue) is more common in patients undergoing device closure than reoperation is in patients undergoing surgical closure. Complications from device closure tend to be serious and most often require urgent or emergency operative management, whereas the mortality for surgical management of a device complication appears higher than that of elective atrial septal defect closure. Further information is required in the form of postmarketing surveillance, such as a mandatory user registry with periodic end-user notification.
                Bookmark

                Author and article information

                Journal
                J Biomed Biotechnol
                J. Biomed. Biotechnol
                JBB
                Journal of Biomedicine and Biotechnology
                Hindawi Publishing Corporation
                1110-7243
                1110-7251
                2012
                2 October 2012
                : 2012
                : 735989
                Affiliations
                Department of Cardiology, Changhai Hospital, Second Military Medical University, Shanghai 200433, China
                Author notes

                Academic Editor: George E. Plopper

                Article
                10.1155/2012/735989
                3471027
                23093859
                d7edadae-4ae3-4003-ac5a-b8cb69e47fdc
                Copyright © 2012 Yu-feng Zhu et al.

                This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 14 June 2012
                : 7 August 2012
                : 7 August 2012
                Categories
                Research Article

                Molecular medicine
                Molecular medicine