11
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Use of Cardiac Computerized Tomography to Predict Neo–Left Ventricular Outflow Tract Obstruction Before Transcatheter Mitral Valve Replacement

      review-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Although the incidence of mitral stenosis has declined precipitously in the Western world due to the reduced incidence of rheumatic heart disease, mitral regurgitation remains one of the most common valvular pathologies.1 Many patients affected by severe mitral valve disease are elderly with multiple comorbidities and are at high risk for traditional open surgical mitral valve repair or replacement. The emergence of minimally invasive strategies for the treatment of mitral regurgitation, such as placement of a percutaneous edge‐to‐edge device (MitralClip, Abbott, Santa Clara, CA) to help improve the severity of mitral regurgitation has proven a successful alternative to open surgery in selected patients.2 This technique, however, is not possible in every patient because of anatomic limitations. Another important patient group that can be high risk for operative intervention includes those with degenerative prosthetic mitral valves or annuloplasty rings. The major cause of bioprosthetic mitral valve dysfunction is cusp calcification causing leaflet thickening and stiffening, which can result in valve stenosis with or without concomitant regurgitation related to leaflet tears. Prosthetic valve dysfunction can also result from extensive tissue overgrowth, thrombus, and the development of a paravalvular leak. The 15‐year reintervention rate for bioprosthetic mitral valves is ≈40%,3 but the mortality rate for surgical bioprosthetic valve rereplacement ranges from 3% to 23%,4 which is not appropriate for high‐risk patients with multiple comorbidities. The recent success of transcatheter aortic valve replacement has led to interest in extending this technique to the mitral valve. There are several transcatheter mitral valves in early development, and clinically there have been multiple reports describing the transcatheter implantation of replacement valves in the mitral position among patients with severe mitral annular calcification, mitral annular rings, or bioprosthetic mitral valves.5, 6 The emergence of transcatheter mitral valve replacement (TMVR) as a distinct procedure presents a unique challenge to clinicians. The complex anatomy of the mitral valve annulus and its proximity to the left ventricular outflow tract (LVOT) make preprocedural evaluation crucial. There is an important need to understand the 3‐dimensional (3D) relationship between the aortic and mitral valves in order to select an appropriately sized valve and predict whether TMVR will result in obstruction of the left ventricular outflow track from the anterior leaflet of the mitral valve. In this article we provide an overview of how to use cardiac computed tomography (CT) to project neo‐LVOT measurements pre‐TMVR and illustrate how this technique has performed across a series of clinical cases. Left Ventricular Outflow Tract Anatomy The LVOT is the region of the left ventricle (LV) that lies between the anterior leaflet of the mitral valve posteriorly and the interventricular septum anteriorly.7 It is a conduit between the lumen of the LV inferiorly and the aortic valve leaflets superiorly, although there is no clear anatomic demarcation between the LVOT and the LV cavity. In normal anatomy the LVOT lies at an approximate angle of 45° from the median plane and is directly posterior to the right ventricular outflow tract. Its anterior wall consists of both the membranous and muscular parts of the interventricular septum. The atrioventricular node typically lies at the junction between these two components of the interventricular septum. The LVOT posterior wall is formed by the fusion of the anterior and posterior mitral cusps, the intervalvular fibrosa, and the mitral valve anterior leaflet from superior to inferior. The intervalvular fibrosa is a fibrous structure that lies at the junction of the anterior mitral valve leaflet and the noncoronary cusp of the aortic valve and is the basis of fibrous skeleton of the heart.8 The LVOT lumen is predominantly oval in shape, but is dynamic and changes in both size and shape throughout the cardiac cycle. It appears more circular during systole, but has a wider transverse than anteroposterior diameter throughout the cardiac cycle.9 Left Ventricular Outflow Tract Obstruction Obstruction of the LVOT can be either fixed or dynamic. Fixed obstruction can be caused by a congenital abnormality in the LVOT, such as a subaortic membrane or a fibrous ring. Less frequently, a tumor can also cause LVOT obstruction. The most common cause of dynamic LVOT obstruction is hypertrophic cardiomyopathy (HCM), occurring in ≈25% of patients.10 The mechanism of LVOT obstruction in HCM usually involves anterior motion of the mitral valve during systole causing mitral‐septal contact by the leading edge of the anterior mitral leaflet.11 LVOT obstruction in HCM or hypertensive cardiomyopathy can also be caused by septal hypertrophy in the absence of systolic anterior movement, although this is less common. Studies in HCM have identified a consistent link between increased LVOT pressure gradients and cardiovascular events and heart failure symptoms, with a higher probability of death in patients with LVOT obstruction.10, 12 Severe LVOT obstruction can cause syncope due to cerebral hypoperfusion and can lead to ventricular arrhythmias. Another consequence of LVOT obstruction is the redirection of LV stroke volume toward the mitral valve, resulting in mitral regurgitation. There is a risk of LVOT obstruction secondary to systolic anterior movement of ≈4% following repair of a myxomatous regurgitant mitral valve due to excess leaflet tissue.13 LVOT obstruction is a rarer complication of surgical mitral valve replacement; its true incidence is difficult to evaluate, but it is likely less than 1%.14, 15, 16 This can result from improper orientation of a bioprosthetic mitral valve strut, from imposition of a large valve strut into a small LVOT, or from a mechanical valve prosthesis having been sutured low to a preserved residual mitral valve leaflet.17, 18 During systole the prosthesis is then free to move anteriorly and can obstruct the LVOT.16 Because TMVR involves placement of an in‐situ valve prosthesis, it can potentially cause LVOT obstruction by pushing the native anterior mitral leaflet or bioprosthetic leaflet into the LVOT. Although there is limited data thus far on the incidence of LVOT obstruction post TMVR, initial data suggest a rate of acute LVOT obstruction of ≈7% to 9%,19 with higher rates occurring in patients with severe mitral annular calcification20, or in those undergoing valve‐in‐valve or valve‐in‐ring procedures.21 Reduction in the LVOT cross‐sectional area is one of the principal causes of LVOT obstruction observed in HCM.22 Bapat et al studied the factors that influence LVOT obstruction in transcatheter mitral valve implantation.23 The authors concluded that the degree of incursion of the prosthetic mitral valve into the LVOT was the main factor in predicting obstruction. The size of the native LVOT and the angle between the aortic and mitral annular planes are associated with an increased risk for obstruction. The aortomitral angle, determined by measuring the interior angle created by the intersection of a virtual plane drawn through the mitral and aortic annuli, is associated with a higher chance of LVOT obstruction as this angle becomes more acute. With the use of modern postprocessing software used in cardiac CT, one can predict the size of the neo‐LVOT by simulating the 3D interactions between the “best‐fit” prosthetic valve and the native valves. In turn, the size of the neo‐LVOT can be used to estimate the risk of LVOT obstruction after TMVR.24, 25 However, it is important to note that the dimensions of the neo‐LVOT are highly dependent on the size of the LV cavity, and thus loading conditions, as well as on the exact location (ie, angle and height) of TMVR implantation. To determine the size of the neo‐LVOT, we first describe the method by which we project the anticipated 3D anatomical interactions between the prosthetic valve and a given patient's cardiac anatomy. Cardiac CT Data Acquisition The cardiac CT protocol for preprocedure TMVR assessment involves performing a gated multiphase cardiac CT with intravenous contrast. Unlike coronary CT angiography studies, β‐blocker or nitroglycerin is not routinely used unless there is a specific request to interrogate the coronary arteries for stenosis. Patients are usually scanned at either 120 or 100 peak kilovoltage depending on size with automated tube current milliampere (mA) modulation. Although the contrast dose varies with the type of scanner, protocol used, and patient size, a dose of 30 to 60 mL is usually sufficient. For a standard patient scanned at 120 kV peak, we recommend using 50 mL of contrast injected at a rate of 4 to 5 mL/s followed by 40 mL of saline. We time the scan acquisition by using a bolus tracking technique, with the region of interest placed in the descending thoracic aorta. In patients with severe renal dysfunction with a glomerular filtration rate (GFR) less than 30 mL/min/1.73 m2, we perform the CT with 30 mL of intravenous contrast. In these low contrast‐dose CTs, image contrast can be improved by reducing the peak kilovoltage, and by injecting the contrast at a higher rate (eg, 5‐6 mL/s). We use prospective ECG gating with acquisition of data from a full R‐R interval for all patients, including those with atrial fibrillation. It is important to acquire images throughout the cardiac cycle, as this allows an assessment of the dynamic changes in the mitral annulus and LVOT. This can be achieved by using either an axial acquisition (for example, with wide‐area detector scanners with complete cardiac coverage in a single gantry rotation) or a helical (for example, with dual‐source scanners, which offer a higher temporal resolution) acquisition with prospective EC gating. Using modern postprocessing software, multiphase data sets can be simultaneously loaded, allowing mitral annular measurements to be performed throughout various phases of the cardiac phase. The mitral annulus typically is larger toward the end of systole at ≈30% to 40% of the R‐R interval in normal individuals, although annular dynamics are affected by disease processes such as ischemic MR or myxomatous degeneration.25, 26 End‐systole is usually the period of the cardiac cycle when the LVOT cross‐sectional area is at its nadir, making this the optimum phase in which to assess for neo‐LVOT obstruction.9 This may or may not be the same phase as when the mitral annulus is at its largest dimension, further underlying the need for having a multiphase acquisition. Cardiac CT Image Reconstruction After data acquisition, images from different phases of the cardiac cycle are reconstructed using a typical range of 0% to 95% of the R‐R interval with 5% increments and a slice thickness of 0.5 mm. We use 3D postprocessing software (Vitrea, Vital Images, Toshiba, Tokyo, Japan) to perform mitral annular measurements and to predict the risk of neo‐LVOT obstruction. Mitral Annulus Assessment Using a 3D Workstation Native Valve Accurately measuring annular size in a native mitral valve is crucial in valve sizing for TMVR planning. The prosthetic valve must provide an adequate seal to prevent further valve dysfunction. For example, paravalvular regurgitation may occur if the prosthesis is too small relative to the size of the mitral annulus. Providing these measurements can, however, be challenging. Unlike the aortic valve annulus, the mitral valve annulus is a nonplanar structure and has a saddle shape.27 The anterior peak of this saddle is continuous with the aortic annulus, the posterior peak is the insertion of the posterior mitral valve leaflet, and the nadirs of the saddle are at the level of the medial and lateral fibrous trigones (Figure 1). Because the mitral annulus is nonplanar, accurate measurement for device sizing is challenging. Blanke et al have proposed that the anterior horn of the saddle‐shaped annulus be excluded for TMVR assessment, creating a “D‐shaped” annulus suitable for planar measurements, with the anterior border a virtual line connecting the fibrous trigones.25, 28 One disadvantage of using the D‐shape annulus approach, however, is that it does not always correspond with the shape of the device, which can be circular, depending on the degree of capture at the level of the trigones. Importantly, the entire geometric shape of the device needs to be taken into account in assessing for neo‐LVOT obstruction. Figure 1 Performing mitral annular measurements and defining the annular plane on cardiac computerized tomography. A, Short‐axis view of the mitral annular region demonstrates the medial (black arrow) and lateral (white arrow) fibrous trigones, the anterior mitral valve leaflet (arrowhead), with delineation of the annular perimeter (red oval). The green and red lines in (B) demonstrate the orientation of the commissural view in (C) and long‐axis view in (D), with delineation of the mitral annular plane. The annular plane can be defined by using a combination of short and long axis reformats of the left ventricle, which can identify the insertion points of the mitral valve leaflets (Figure 1). Once the annular plane has been defined, the maximum and minimum annular diameters, annulus area, and perimeter can be measured (Figure 2). By performing these measurements at the maximal annular size, information on prosthesis sizing can be provided, reducing the risk of significant post device implantation paravalvular regurgitation. Figure 2 Predicting neo–left ventricular outflow tract (LVOT) area in a native mitral valve on postcontrast cardiac computerized tomography (CT). A, Left ventricle short‐axis multiplanar reformat (MPR) at the level of the mitral annulus demonstrates mitral annulus measurements. Note the mild mitral annular calcification. B, A 3‐dimensional (3D) circular volume‐rendered segmentation (red circle) is performed at the corresponding level of the mitral annulus with the dimensions of the proposed prosthetic valve (in this case a 29‐mm Edwards SAPIEN XT valve). C, This creates a 3D segmented cylindrical volume (green cylinder), viewed here in profile. D, Once segmented, the segmented 3D volume can be projected onto the CT image data, as demonstrated on this 4‐chamber MPR (red volume). E, The proposed prosthetic valve height is then measured (line) and segmented (F) as demonstrated on these 2‐chamber MPRs. G, A 3‐chamber MPR can determine the level of the minimal neo‐LVOT (blue line), and planimetry of the neo‐LVOT can be performed in an orthogonal plane (H). Valve in Valve and Valve in Ring The most commonly used method to select a valve size in a patient with an existing prosthetic mitral valve or ring is through the Valve in Valve Mitral smartphone application (UBQO Ltd, London, UK). This application does not, however, address the risk of LVOT obstruction; therefore, obtaining a CT in these cases is important. There is an increased risk of LVOT obstruction in valve‐in‐valve cases, as the old valve can become a cylindrical fixed obstruction after the new valve is placed, and in valve‐in‐ring procedures the new valve can pin the old valve leaflets open, wrapping the anterior mitral leaflet around the new valve, impinging on the LVOT area.23 Limited series thus far have reported combined rates of LVOT obstruction following valve‐in‐valve or valve‐in‐ring procedures of ≈7%, with a higher prevalence in the valve‐in‐ring cases.21 Mitral annulus assessment on CT in the setting of an existing mechanical valve, bioprosthetic valve, or following repair with a mitral ring is often more straightforward than in the case of a native valve (Figures 3 and 4). In such cases the annular plane will be perpendicular to the long axis of the prosthesis, and measurements should be performed between the inner borders of the existing prosthesis, as this is where the new device will sit. When performing measurements of such valves or rings, it is important to use the thinnest possible slices as well as to optimize the display settings to minimize beam hardening. This can be accomplished by using a wide range for the grayscale viewing window. In addition, the use of a higher peak kilovoltage during CT acquisition may also reduce beam‐hardening artifacts. Figure 3 Predicting neo–left ventricular outflow tract (LVOT) area in a prosthetic mitral valve on postcontrast cardiac computerized tomography (CT) using 30 mL iodinated contrast. A, Left ventricle short‐axis multiplanar reformat (MPR) at the level of the mechanical mitral valve demonstrates mitral valve prosthetic measurements. B, A 3‐dimensional (3D) volume segmentation (red circle) is performed of the internal surface of the prosthetic valve at the corresponding level of the mitral annulus with the dimensions of the proposed prosthetic valve (in this case a 23‐mm Edwards SAPIEN XT valve). C, Four‐chamber MPR demonstrates the resulting segmented volume (red volume). D, The valve height (line) is then segmented (E), and 4‐chamber MPR shows the proposed valve prosthesis. F, A 3D segmented volume‐rendered image demonstrates the prosthetic valve volume (green cylinder) in profile inside the existing prosthesis. G, Three‐chamber MPR demonstrates the level of the neo‐LVOT (blue line), with planimetry of the neo‐LVOT performed in an orthogonal plane (H). Figure 4 Predicting neo–left ventricular outflow tract (LVOT) area in a bioprosthetic mitral valve on postcontrast cardiac computerized tomography (CT). A, Left ventricle short‐axis multiplanar reformat (MPR) at the level of the bioprosthetic mitral valve, with annotated measurements (B). C, Three‐chamber MPR demonstrates the proposed valve prosthesis, in this case a 26‐mm Edwards SAPIEN XT valve. Planimetry of the neo‐LVOT (C, red line), with planimetry of the neo‐LVOT performed in an orthogonal plane (D). The annuloplasty rings will have a D‐shape, which may increase the risk of paravalvular leak after transcatheter valve implantation if incomplete sealing occurs. Certain annuloplasty rings are more deformable than others and thus may be more amenable to a transcatheter valve‐in‐ring procedure depending on their flexibility.4 Mitral Annular Calcification Mitral annular calcification (MAC) is a common degenerative process of the mitral annulus of uncertain clinical significance, with a prevalence of ≈6.1% in the general population.29 Notably, the presence of severe MAC can be helpful for TMVR implantation because it may aid in creating a seal around the new valve thereby reducing paravalvular leak, especially if the MAC is full or near full circumference.20 However, the presence of severe MAC can introduce limitations in viewing and measuring the size of the mitral valve annulus on CT. The use of interactive windowing to create a wide CT viewing window is useful when assessing the mitral annulus in the presence of significant MAC, as this technique can help reduce the deleterious blooming effect from calcium. Conversely, the presence of MAC can aid the 3D segmentation of the mitral annulus when neo‐LVOT assessment is performed in pre‐TMVR CT (outlined below), providing a high‐contrast outline of the annulus (Figure 5). Caseous annular calcification is a rare variant of MAC that can form bulky, masslike calcified lesions along the posterior annulus border, further hindering accurate annular measurement.30, 31 Figure 5 Predicting neo–left ventricular outflow tract (LVOT) area in a native mitral valve with severe mitral annular calcification on postcontrast cardiac computerized tomography (CT) using 30 mL iodinated contrast. A, Left ventricle short‐axis multiplanar reformat (MPR) at the level of the mitral annulus with severe mitral annular calcification, with (B) mitral annular measurements and segmented valve area. Three‐chamber MPR (C) demonstrates the proposed valve prosthesis, in this case a 29‐mm Edwards SAPIEN XT valve. Planimetry of the neo‐LVOT (C, blue line), with planimetry of the neo‐LVOT performed in an orthogonal plane (D). Neo‐LVOT Assessment After implantation of a percutaneous mitral valve, there is displacement of the anterior mitral valve leaflet, forming a longer neo‐LVOT. The potential risk of neo‐LVOT obstruction with TMVR can be assessed on a preprocedural cardiac CT by simulating the position and size of the valve prosthesis in the mitral annulus using 3D segmentation techniques available with postprocessing software. The minimal area of the neo‐LVOT can help determine the risk for neo‐LVOT obstruction. The major risk factors for neo‐LVOT obstruction are (1) aortomitral angulation, (2) LV size, (3) interventricular septum size, and (4) device‐related factors.23, 25 The aortomitral angle is the internal angle formed by the intersection of the mitral and aortic annular planes. A parallel orientation is associated with a lower risk of LVOT obstruction, with a perpendicular orientation conferring the highest risk.23 Small LV cavity size is a known risk factor for LVOT obstruction after surgical valve replacement, whereas a larger LV cavity will more easily accommodate a device without impinging on the LVOT.15, 32 As described in the context of HCM, the size of the basal interventricular septum can have an effect on LVOT area, with septal hypertrophy a known cause of LVOT obstruction. The device‐related factors that may impact on potential neo‐LVOT obstruction are protrusion and flaring. Some devices may have an outward flare from the annular to the ventricular portion, which may encroach into the neo‐LVOT, increasing the risk of obstruction. The most important device‐related factor is the degree to which it protrudes into the neo‐LVOT, reducing its cross‐sectional area. This is highly dependent on the height of the device and its site of deployment relative to the mitral annulus. The valve prosthesis can be projected onto the mitral annulus using 3D segmentation techniques. The cross‐sectional area of the neo‐LVOT can then be measured by planimetry using a multiplanar reformat plane orthogonal to the LVOT centerline (Figures 2, 3, 4 through 5). There are, as yet, no defined neo‐LVOT cross‐sectional area cutoff values to diagnose obstruction definitively. The majority of the available data on LVOT obstruction comes from HCM and aortic stenosis studies. An LVOT area >2.7 cm2 seems to reliably exclude LVOT obstruction in patients with HCM, but values less than this are more difficult to interpret.33 One study in HCM patients found an LVOT area of 2.0 cm2 to be a reliable cutoff between obstructive and nonobstructive HCM,34 with another study finding an association between an LVOT area <0.85 cm2 and a resting pressure gradient >50 mm Hg.35 This heterogeneity is likely due to the significant inter‐individual variation in LVOT area according to body surface area, a phenomenon that has been described on CT in normal individuals.9 Thus, metrics such as neo‐LVOT/aorta area ratio may be potentially useful, taking into account interindividual variation due to body habitus. Vogel‐Claussen et al found in a study of HCM patients that an LVOT/aorta diameter ratio of less than 0.25 was associated with obstructive LVOT pressure gradients.36 Furthermore, in selected cases, when necessary, it is possible to modify the LVOT shape and size using alcohol ablation, which may allow for successful TMVR despite the presence of a small predicted LVOT.37 Prospective studies will be required to determine minimum acceptable neo‐LVOT area in the context of TMVR, but until such results are available, a cutoff of ≤2.0 cm2 appears reasonable in conferring risk of neo‐LVOT obstruction, with an area of <1.5 to 1 cm2 conferring an even higher risk. Mitral Valve Prostheses In order to measure the size of the neo‐LVOT, a 3D workstation is first used to create a cylindrical volume that has the dimensions of each potential valve being considered. Before creating the cylindrical volume on CT to simulate the prosthetic valve, it is important to consider its dimensions, especially its height, because this will ultimately determine the predicted neo‐LVOT area. Clinically, TMVR is primarily performed using balloon‐expandable Edwards SAPIEN devices (Edwards Lifesciences, Irvine, CA), but several newer devices are coming to market, including dedicated TMVR valves. Although no dedicated TMVR valves are yet approved for routine clinical use,38, 39, 40, 41, 42 transcatheter aortic valve replacement valves are now commonly used for this procedure, and the SAPIEN 3 valve (Edwards Lifesciences, Irvine, CA) has recently been approved by the Food and Drug Administration for mitral valve use.43 It is important for the imagers to familiarize themselves with the dimensions of these devices as well as those of the surgically implanted mitral rings and bioprosthetic valves when simulating the cylindrical volume (Table). Although understanding the design, structure, and sizing of potential future novel devices is beyond the scope of this article, we believe that the principles we have covered will be applicable to most valves that are being evaluated. It will still be important to know the dimensions and flow profiles of any novel valves for estimating the risk of LVOT obstruction. Table 1 Transcatheter Mitral Valve Characteristics Valve Manufacturer MV Specific Commercially Available Diameter at MA (mm) Expanded Height (mm) SAPIEN XT Edwards Lifesciences, Irvine, CA No Yes 23 26 29 14.3 17.2 19.1 SAPIEN 3 Edwards Lifesciences, Irvine, CA No Yes 20 23 26 29 15.5 18 20 22.5 LOTUS Boston Scientific, Marlborough, MA No Yes 23 25 27 19 19 19 FORTISa Edwards Lifesciences, Irvine, CA Yes No 29 N/A CardiAQa CardiAQ Valve Technologies, Irvine, CA Yes No 40 N/A Tendynea Tendyne Inc, Roseville, MN Yes No 30 to 43b 30 to 50b Tiaraa Neovasc Inc, Richmond, BC, Canada Yes No 35 35 Twelve valvea Twelve Inc, Menlo Park, CA Yes No N/A N/A Medtronic mitrala Medtronic, Minneapolis, MN Yes No N/A N/A NaviGatea NaviGate Cardiac Structures, Lake Forest, CA Yes No 30 21 MA indicates mitral annulus; MV, mitral valve; N/A, not available. a Valves currently enrolled in early feasibility clinical trials. Complete valve dimensions are not yet available. b Adjustable. Transcatheter Prosthesis Size Selection To assess the risk of LVOT obstruction, it is important to know what transcatheter prosthesis size the implanter will select, because the degree of LVOT obstruction will be greater with larger‐diameter prostheses owing to their taller stent heights. For valve‐in‐valve procedures, knowledge of the surgical bioprosthesis in place is of paramount importance. If the exact prosthesis is known, then the internal diameter of the prosthesis can be determined, and an appropriate valve size can be selected. For valve‐in‐ring procedures and valve‐in‐MAC procedures, the size of transcatheter prosthesis chosen may be less clear, as it is unlikely that a circular transcatheter prosthesis will fully appose the ring or mitral annulus, and therefore there may be a greater chance of paravalvular regurgitation. The implanter will have to decide between choosing a smaller prosthesis (thereby minimizing risk of LVOT obstruction) but having to potentially treat severe paravalvular regurgitation with percutaneous occlusion of the leaking areas, or choosing a larger prosthesis that may minimize leak but increase risk of LVOT obstruction. Therefore, it is important to model multiple sizes of transcatheter heart valves when assessing the risk of LVOT obstruction. In general, for valve‐in‐valve cases, the valve size is selected based on the true inner diameter of the existing valve, which is the inner dimension of the valve minus the contribution of the valve leaflets after they get pushed up. Consequently, the implantable valve one size up from the true inner diameter is usually selected. The volume of fluid used in the delivery balloon can then be varied to ensure that the valve is flared when deployed. Valve Simulation to Predict Neo‐LVOT Obstruction By segmenting a cylindrical volume in the expected position of the prosthetic valve at the mitral annulus, it is possible to predict the minimal cross‐sectional area of the neo‐LVOT. The mitral annular measurement will help in selecting the appropriate valve size. The volume can be segmented according to the diameter and height of the prostheses (Figures 2, 3, 4 through 5). The optimal position of the prosthetic valve in the mitral annulus will depend on the individual design of the particular device used, but in general, the device position should be simulated on the CT images with an atrial‐ventricular ratio of ≈20:80 to 25:75 for native valves, valve‐in‐valve and valve‐in‐ring procedures.24 If the valve is placed with a higher atrial ratio, the risk of valve migration is increased, and the risk of LVOT obstruction is reduced, and vice versa. For valve‐in‐ring cases, it is important to deploy the valve with the sealing skirt against the ring to prevent leaking through the uncovered stent struts. Typically, the selected TMVR valve is oversized relative to the annulus, leading to the ventricular aspect of the valve “flaring” out slightly relative to the valve anchored in the mitral annulus. Implanters generally aim to flare the ventricular aspect of the transcatheter prosthesis to fully ensure that the prosthesis is well anchored against the sewing ring of the surgical valve and thereby minimizing the risk of atrial migration of the transcatheter valve over time. This should be taken into account when simulating a virtual valve implantation. Once the location of the simulated prosthetic valve is determined, the contours of the neo‐LVOT can be demonstrated by creating a standard 3‐chamber multiplanar reformat. The predicted minimal neo‐LVOT cross‐sectional area can be performed via planimetric assessment on a multiplanar reformat orthogonal to the centerline of the neo‐LVOT on the 3‐chamber multiplanar reformat. The same technique can be employed when assessing native valves, valve‐in‐valve, or valve‐in‐ring cases (Figures 6 and 7). Figure 6 A through D, ECG gated, contrast‐enhanced cardiac computerized tomography (CT) images at end systole showing (A) commissural and (B) 3‐chamber views with a simulated cylindrical device (29 mm) oriented perpendicularly to the annular plane. One third of the cylinder volume is projected to remain above the plane in the commissural view. The neo–left ventricular outflow tract (LVOT) formed by the septal myocardium and the device is shown in (C) with cross‐sectional area of 2.0 cm2, indicating risk for LVOT obstruction. D, Three‐dimensional segmented rendering of the cylinder within the left ventricle. E through H, Contrast‐enhanced cardiac CT at end systole showing a deployed 26‐mm Edwards SAPIEN 3 transcatheter heart valve in the mitral position, which was placed more apically than on the 3‐dimensional (3D) simulation. Commissural (E), 3‐chamber (F), and neo‐LVOT (G) views demonstrate end‐systolic area of 0.99 cm2. A transthoracic echocardiogram (H) showed flow acceleration across the LVOT with evidence of dynamic obstruction (peak gradient measured at 58 mm Hg and mean gradient at 26 mm Hg). Despite this, the procedure was clinically successful, as the patient experienced significant improvement in her functional status. Mean gradients across the mitral valve decreased from 11 mm Hg (at a heart rate of 70 beats/min) to 6 mm Hg (at a heart rate of 80 beats/min). Figure 7 A through D, ECG gated, contrast‐enhanced cardiac computerized tomographic image (CT) at end systole showing (A) commissural and (B) 3‐chamber views with a simulated Edwards SAPIEN XT valve (26 mm) oriented perpendicularly to the annular plane of a bioprosthetic St. Jude valve (27 mm). Note the acute aortomitral angle. One third of the cylinder volume is projected to remain above the annular plane. The neo–left ventricular outflow tract (LVOT) formed by the septal myocardium and the device is shown (C) with cross‐sectional area of 1.8 cm2, indicating high risk for LVOT obstruction. D, Three‐dimensional (3D) rendering of the cylinder within the left ventricle. E through H, Contrast‐enhanced cardiac CT at end systole showing an Edwards SAPIEN XT transcatheter heart valve (26 mm) in the mitral position. Commissural (E), 3‐chamber (F), and neo‐LVOT (G) views demonstrate end‐systolic area of 1.7 cm2. A transthoracic echocardiogram (H) showed combined peak and mean gradients across the LVOT/bioprosthetic aortic valve of 53 and 32 mm Hg. Pre–transcatheter mitral valve replacement (TMVR) peak and mean gradients across the aortic valve were 37 and 13 mm Hg, respectively. The procedure, performed for early bioprosthetic valve failure and severe mitral regurgitation (MR), was clinically successful. Intraoperative transesophageal echocardiogram showed trivial MR after the deployment of the TMVR, which translated into improved symptoms. Limitations Although cardiac CT provides the ability to measure the neo‐LVOT by direct planimetry, a few technical limitations deserve mention. The neo‐LVOT dimensions are dynamic rather than static measurements throughout the cardiac cycle. It is therefore conceivable that the use of multiple measurements during the cardiac phase may improve the predictive value; however, this process is labor intensive, and reference values are not yet defined. The neo‐LVOT area measurements must also be interpreted with the consideration that they are dependent on volume and loading conditions, which is especially important when dealing with a severe regurgitant lesion. The prediction of the final implant position and angle of the TMVR valve assumes that the valve will deploy directly center in the mitral annulus, which does not account for mitral annular and leaflet compliance and the angle of implant affecting the final position of the valve. Finally, there is recognition that the displacement of the native anterior mitral valve leaflet may also play a significant role in LVOT obstruction, which is not readily assessed on CT.44 Nevertheless, the CT simulation of final valve positioning provides an important starting point to guide patient and valve selection as well as implantation technique. Use of CT to Evaluate LVOT Obstruction Following TMVR In selected cases, when there is a high clinical concern for LVOT obstruction following TMVR due to either pre‐TMVR CT findings or post‐TMVR clinical and echocardiographic findings, cardiac CT can be used to assess the patient's anatomy, actual valve deployment, and subsequent neo‐LVOT (Figures 6 and 7). The type and characteristics of the prosthetic valve itself become relevant in determining obstruction, as some valves may allow flow through their alloy frame, which is included in the manufacturer's description of prosthesis height. Future Opportunities The field of TMVR is still in its infancy in terms of device design, performance, and long‐term outcomes. As is well known for transcatheter aortic valve replacement procedures, pre‐TMVR cardiac CT assessment plays a critical role in terms of patient selection, device selection and sizing, and in predicting potential complications. Novel CT‐based applications, such as the 3mensio Mitral Valve (Pie Medical Imaging, Maastricht, The Netherlands) and cvi42 (Circle Cardiovascular Imaging, Calgary, Canada) allow enhanced simulation of various valve sizes in the heart. These advanced software solutions, although not yet widely available, may further improve the capabilities of cardiac CT in pre‐TMVR planning and neo‐LVOT risk assessment. For instance, improved software may improve consistency between readers in valve sizing and save time relative to standard CT postprocessing techniques. Some institutions have advocated using computer‐aided design solutions to simulate valve sizing and position as well as to assess the risk of potential LVOT obstruction.45 3D printing techniques may also offer the potential for individual assessment of the device‐patient interaction, which may prove valuable in assessing potential complications, such as paravalvular regurgitation or neo‐LVOT obstruction.46, 47 The assessment of neo‐LVOT obstruction itself is more complicated than performing a minimal cross‐sectional area with a simulated prosthesis because of variations in loading conditions. Thus, fluid dynamic modeling may prove a useful adjunct to neo‐LVOT planimetry in the future, especially in borderline cases. Conclusion Cardiac CT plays an important role in the preprocedural evaluation of TMVR. The risk of neo‐LVOT obstruction, a potentially serious complication of prosthetic mitral valve placement, can be assessed on cardiac CT with the use of 3D segmentation techniques available on postprocessing software. Disclosures Dr Bhatt discloses the following relationships: advisory boards of Cardax, Elsevier Practice Update Cardiology, Medscape Cardiology, Regado Biosciences; Board of Directors of Boston VA Research Institute, Society of Cardiovascular Patient Care; Chair of American Heart Association Quality Oversight Committee; data‐monitoring committees of Cleveland Clinic, Duke Clinical Research Institute, Harvard Clinical Research Institute, Mayo Clinic, Mount Sinai School of Medicine, Population Health Research Institute; honoraria from American College of Cardiology (Senior Associate Editor, Clinical Trials and News, ACC.org), Belvoir Publications (Editor in Chief, Harvard Heart Letter), Duke Clinical Research Institute (clinical trial steering committees), Harvard Clinical Research Institute (clinical trial steering committee), HMP Communications (Editor in Chief, Journal of Invasive Cardiology), Journal of the American College of Cardiology (Guest Editor; Associate Editor), Population Health Research Institute (clinical trial steering committee), Slack Publications (Chief Medical Editor, Cardiology Today's Intervention), Society of Cardiovascular Patient Care (Secretary/Treasurer), WebMD (CME steering committees); others including Clinical Cardiology (Deputy Editor), NCDR‐ACTION Registry Steering Committee (Chair), VA CART Research and Publications Committee (Chair); research funding from Amarin, Amgen, AstraZeneca, Bristol‐Myers Squibb, Chiesi, Eisai, Ethicon, Forest Laboratories, Ironwood, Ischemix, Lilly, Medtronic, Pfizer, Roche, Sanofi Aventis, The Medicines Company; royalties from Elsevier (Editor, Cardiovascular Intervention: A Companion to Braunwald's Heart Disease); Site Co‐Investigator for Biotronik, Boston Scientific, St. Jude Medical (now Abbott); trustee of American College of Cardiology; unfunded research for FlowCo, Merck, PLx Pharma, Takeda. Dr Kaneko is a speaker and proctor for Edwards Lifescience. Dr Shah is a speaker and proctor for Edwards LifeSciences, educational course director for Abbott (formerly St. Jude Medical).

          Related collections

          Most cited references42

          • Record: found
          • Abstract: found
          • Article: not found

          Mitral valve disease--current management and future challenges.

          The field of mitral valve disease diagnosis and management is rapidly changing. New understanding of disease pathology and progression, with improvements in and increased use of sophisticated imaging modalities, have led to early diagnosis and complex treatment. In primary mitral regurgitation, surgical repair is the standard of care. Treatment of asymptomatic patients with severe mitral regurgitation in valve reference centres, in which successful repair is more than 95% and surgical mortality is less than 1%, should be the expectation for the next 5 years. Transcatheter mitral valve repair with a MitraClip device is also producing good outcomes in patients with primary mitral regurgitation who are at high surgical risk. Findings from clinical trials of MitraClip versus surgery in patients of intermediate surgical risk are expected to be initiated in the next few years. In patients with secondary mitral regurgitation, mainly a disease of the left ventricle, the vision for the next 5 years is not nearly as clear. Outcomes from ongoing clinical trials will greatly inform this field. Use of transcatheter techniques, both repair and replacement, is expected to substantially expand. Mitral annular calcification is an increasing problem in elderly people, causing both mitral stenosis and regurgitation which are difficult to treat. There is anecdotal experience with use of transcatheter valves by either a catheter-based approach or as a hybrid technique with open surgery, which is being studied in early feasibility trials.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Three-dimensional echocardiographic reconstruction of the mitral valve, with implications for the diagnosis of mitral valve prolapse.

            Mitral valve prolapse has been diagnosed by two-dimensional echocardiographic criteria with surprising frequency in the general population, even when preselected normal subjects are examined. In most of these individuals, however, prolapse appears in the apical four-chamber view and is absent in roughly orthogonal long-axis views. Previous studies of in vitro models with nonplanar rings have shown that systolic mitral annular nonplanarity can potentially produce this discrepancy. However, to prove directly that apparent leaflet displacement in a two-dimensional view does not constitute true displacement above the three-dimensional annulus requires reconstruction of the entire mitral valve, including leaflets and annulus. Such reconstruction would also be necessary to explore the complex geometry of the valve and to derive volumetric measures of superior leaflet displacement. A technique was therefore developed and validated in vitro for three-dimensional reconstruction of the entire mitral valve. In this technique, simultaneous real-time acquisition of images and their spatial locations permits reconstruction of a localized structure by minimizing the effects of patient motion and respiration. By applying this method to 15 normal subjects, a coherent mitral valve surface could be reconstructed from intersecting scans. The results confirm mitral annular nonplanarity in systole, with a maximum deviation of 1.4 +/- 0.3 cm from planarity. They directly show that leaflets can appear to ascend above the mitral annulus in the apical four-chamber view, as they did in at least one view in all subjects, without actual leaflet displacement above the entire mitral valve in three dimensions, thereby challenging the diagnosis of prolapse by isolated four-chamber view displacement in otherwise normal individuals. This technique allows us to address a uniquely three-dimensional problem with high resolution and provide new information previously unavailable from the two-dimensional images. This new appreciation should enhance our ability to ask appropriate clinical questions relating mitral valve shape and leaflet displacement to clinical and pathologic consequences.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Transcatheter Mitral Valve Replacement for Patients With Symptomatic Mitral Regurgitation: A Global Feasibility Trial.

              Symptomatic mitral regurgitation (MR) is associated with high morbidity and mortality that can be ameliorated by surgical valve repair or replacement. Despite this, many patients with MR do not undergo surgery. Transcatheter mitral valve replacement (TMVR) may be an option for selected patients with severe MR.
                Bookmark

                Author and article information

                Contributors
                rblankstein@partners.org
                Journal
                J Am Heart Assoc
                J Am Heart Assoc
                10.1002/(ISSN)2047-9980
                JAH3
                ahaoa
                Journal of the American Heart Association: Cardiovascular and Cerebrovascular Disease
                John Wiley and Sons Inc. (Hoboken )
                2047-9980
                04 November 2017
                November 2017
                : 6
                : 11 ( doiID: 10.1002/jah3.2017.6.issue-11 )
                : e007353
                Affiliations
                [ 1 ] Cardiovascular Imaging Program Departments of Medicine (Cardiovascular Division) and Radiology Brigham and Women's Hospital Harvard Medical School Boston MA
                [ 2 ] University of Washington Seattle WA
                [ 3 ] Mid‐Atlantic Permanente Medical Group McLean VA
                [ 4 ] Cardiovascular Division Brigham and Women's Hospital Boston MA
                [ 5 ] Cardiac Surgery Division Brigham and Women's Hospital Boston MA
                Author notes
                [*] [* ] Correspondence to: Ron Blankstein, MD, FACC, Brigham and Women's Hospital, 75 Francis St, Boston, MA 02115. E‐mail: rblankstein@ 123456partners.org
                Article
                JAH32681
                10.1161/JAHA.117.007353
                5721795
                29102981
                d8326c3c-7a95-4fb4-bf76-7d8bdfe60d79
                © 2017 The Authors. Published on behalf of the American Heart Association, Inc., by Wiley.

                This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited and is not used for commercial purposes.

                History
                Page count
                Figures: 7, Tables: 1, Pages: 13, Words: 8041
                Categories
                Contemporary Review
                Contemporary Reviews
                Custom metadata
                2.0
                jah32681
                November 2017
                Converter:WILEY_ML3GV2_TO_NLMPMC version:5.2.6 mode:remove_FC converted:21.11.2017

                Cardiovascular Medicine
                cardiac ct,mitral valve,transcatheter mitral valve replacement,left ventricular outflow tract,computerized tomography (ct),imaging,valvular heart disease,catheter-based coronary and valvular interventions

                Comments

                Comment on this article