16
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: not found

      Synchrotron Powder Diffraction using Imaging Plates: Crystal Structure Determination and Rietveld Refinement

      Journal of Applied Crystallography
      International Union of Crystallography (IUCr)

      Read this article at

      ScienceOpenPublisher
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          The combination of intense X-ray synchrotron radiation and an imaging-plate area detector makes it possible to extract real-time structural information using Rietveld refinement of individual time slices. Powder diffraction data from capillary samples were collected using a flat imaging plate mounted perpendicular to, or at an oblique angle to, the incoming beam. Owing to the geometry of the experiments, several factors must be taken into account when Rietveld refinement of powder diffraction data obtained using a flat imaging plate is performed: (i) nonequal step sizes are obtained when the diffraction profiles are extracted; (ii) the refined zero-point correction is different from that for conventional diffraction geometry; (iii) the sample-detector distance is not constant, requiring a modified geometric term in the Lorentz factor; (iv) the geometric contribution to the instrumental resolution function must be considered. The geometric factors have been derived and are discussed. The Rietveld program XRS-82 and the profile extraction program ALLHKL have been modified to allow flat imaging-plate powder diffraction data to be refined. The Rietveld refinement of powder diffraction data of α-quartz collected using a 30 s exposure is presented. LaB 6 powder diffraction data were collected using various settings. The profile variation with angle and the resolution function are described. Data were collected up to sin θ/ λ = 1.29 Å −1 ( d values down to 0.39 Å) using high energy and with the imaging plate inclined at an angle to the incoming beam.

          Related collections

          Author and article information

          Journal
          JACGAR
          Journal of Applied Crystallography
          J Appl Crystallogr
          J Appl Cryst
          International Union of Crystallography (IUCr)
          0021-8898
          February 1997
          February 01 1997
          : 30
          : 1
          : 21-30
          Article
          10.1107/S0021889896009995
          d839b012-8bd9-4f36-94c4-2a74f4c06e67
          © 1997

          http://journals.iucr.org/services/copyrightpolicy.html

          http://journals.iucr.org/services/copyrightpolicy.html#TDM

          History

          Comments