28
views
0
recommends
+1 Recommend
1 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Choosing the right inhaler for your asthma or COPD patient

      review-article
      Therapeutics and Clinical Risk Management
      Dove Medical Press
      inhaler, asthma, COPD, adherence

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Appropriate selection and correct use of inhalation devices is an integral component in the management of asthma and chronic obstructive pulmonary disease (COPD). It is well known that there are many challenges with the use of inhalers, and no one device suits all patients. Challenges can range from difficulties related to lung disease severity and pulmonary function to physical considerations, including manual dexterity and comorbidities such as arthritis. In terms of device selection and adherence, patient engagement and satisfaction are also important factors to consider. Furthermore, problems with inhaler use can be most evident in children and older patients. Here, we discuss aspects for consideration with commonly used devices, including nebulizers, pressurized metered-dose inhalers, dry powder inhalers, and the soft mist inhaler. As each inhaler offers varying technical properties, a tailored and personalized approach to the selection of the most appropriate device for the patient is highly recommended in order to increase the likelihood of achieving improved disease outcomes and enhance persistence with device adherence. Importantly, education and support is crucial, not only to enable patients to recognize the need for optimal disease management, but also to help them develop good inhaler technique. In addition, health care professionals should also aim to increase their knowledge of the devices they prescribe, and develop systems to ensure that they offer comprehensive support to patients in clinical practice. Considering these aspects, this review discusses potential strategies to help address the challenges of inhaler use in asthma and COPD.

          Video abstract

          Most cited references80

          • Record: found
          • Abstract: found
          • Article: not found

          Regional lung deposition and bronchodilator response as a function of beta2-agonist particle size.

          Aerosol particle size influences the extent, distribution, and site of inhaled drug deposition within the airways. We hypothesized that targeting albuterol to regional airways by altering aerosol particle size could optimize inhaled bronchodilator delivery. In a randomized, double-blind, placebo-controlled study, 12 subjects with asthma (FEV1, 76.8 +/- 11.4% predicted) inhaled technetium-99m-labeled monodisperse albuterol aerosols (30-microg dose) of 1.5-, 3-, and 6-microm mass median aerodynamic diameter, at slow (30-60 L/min) and fast (> 60 L/min) inspiratory flows. Lung and extrathoracic radioaerosol deposition were quantified using planar gamma-scintigraphy. Pulmonary function and tolerability measurements were simultaneously assessed. Clinical efficacy was also compared with unlabeled monodisperse albuterol (15-microg dose) and 200 microg metered-dose inhaler (MDI) albuterol. Smaller particles achieved greater total lung deposition (1.5 microm [56%], 3 microm [50%], and 6 microm [46%]), farther distal airways penetration (0.79, 0.60, and 0.36, respective penetration index), and more peripheral lung deposition (25, 17, and 10%, respectively). However, larger particles (30-microg dose) were more efficacious and achieved greater bronchodilation than 200 microg MDI albuterol (deltaFEV1 [ml]: 6 microm [551], 3 microm [457], 1.5 microm [347], MDI [494]). Small particles were exhaled more (1.5 microm [22%], 3 microm [8%], 6 microm [2%]), whereas greater oropharyngeal deposition occurred with large particles (15, 31, and 43%, respectively). Faster inspiratory flows decreased total lung deposition and increased oropharyngeal deposition for the larger particles, with less bronchodilation. A shift in aerosol distribution to the proximal airways was observed for all particles. Regional targeting of inhaled beta2-agonist to the proximal airways is more important than distal alveolar deposition for bronchodilation. Altering intrapulmonary deposition through aerosol particle size can appreciably enhance inhaled drug therapy and may have implications for developing future inhaled treatments.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: found
            Is Open Access

            Critical inhaler errors in asthma and COPD: a systematic review of impact on health outcomes

            Background Inhaled drug delivery is the cornerstone treatment for asthma and chronic obstructive pulmonary disease (COPD). However, use of inhaler devices can be challenging, potentially leading to critical errors in handling that can significantly reduce drug delivery to the lungs and effectiveness of treatment. Methods A systematic review was conducted to define ‘critical’ errors and their impact on health outcomes and resource use between 2004 and 2016, using key search terms for inhaler errors in asthma and COPD (Search-1) and associated health-economic and patient burden (Search-2). Results Search-1 identified 62 manuscripts, 47 abstracts, and 5 conference proceedings (n = 114 total). Search-2 identified 9 studies. We observed 299 descriptions of critical error. Age, education status, previous inhaler instruction, comorbidities and socioeconomic status were associated with worse handling error frequency. A significant association was found between inhaler errors and poor disease outcomes (exacerbations), and greater health-economic burden. Conclusions We have shown wide variations in how critical errors are defined, and the evidence shows an important association between inhaler errors and worsened health outcomes. Given the negative impact diminished disease outcomes impose on resource use, our findings highlight the importance of achieving optimal inhaler technique, and a need for a consensus on defining critical and non-critical errors. Electronic supplementary material The online version of this article (10.1186/s12931-017-0710-y) contains supplementary material, which is available to authorized users.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Inhaler Errors in the CRITIKAL Study: Type, Frequency, and Association with Asthma Outcomes.

              Poor inhaler technique has been linked to poor asthma outcomes. Training can reduce the number of inhaler errors, but it is unknown which errors have the greatest impact on asthma outcomes.
                Bookmark

                Author and article information

                Journal
                Ther Clin Risk Manag
                Ther Clin Risk Manag
                Therapeutics and Clinical Risk Management
                Therapeutics and Clinical Risk Management
                Dove Medical Press
                1176-6336
                1178-203X
                2019
                14 March 2019
                : 15
                : 461-472
                Affiliations
                National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, Airways Disease Section, London, UK, o.usmani@ 123456imperial.ac.uk
                Author notes
                Correspondence: Omar S Usmani, National Heart and Lung Institute (NHLI), Imperial College London and Royal Brompton Hospital, Airways Disease Section, Dovehouse Street, London SW3 6LY, UK, Tel +44 207 351 8051 ext 8929, Fax +44 207 351 8937, Email o.usmani@ 123456imperial.ac.uk
                Article
                tcrm-15-461
                10.2147/TCRM.S160365
                6422419
                30936708
                d83c47f8-902c-4eb1-be5d-9bd4dfd2b2bb
                © 2019 Usmani. This work is published and licensed by Dove Medical Press Limited

                The full terms of this license are available at https://www.dovepress.com/terms.php and incorporate the Creative Commons Attribution – Non Commercial (unported, v3.0) License ( http://creativecommons.org/licenses/by-nc/3.0/). By accessing the work you hereby accept the Terms. Non-commercial uses of the work are permitted without any further permission from Dove Medical Press Limited, provided the work is properly attributed.

                History
                Categories
                Review

                Medicine
                inhaler,asthma,copd,adherence
                Medicine
                inhaler, asthma, copd, adherence

                Comments

                Comment on this article