4
views
0
recommends
+1 Recommend
0 collections
    0
    shares
      • Record: found
      • Abstract: found
      • Article: found
      Is Open Access

      Rapid Detection and Differentiation of Legionella pneumophila and Non -Legionella pneumophila Species by Using Recombinase Polymerase Amplification Combined With EuNPs-Based Lateral Flow Immunochromatography

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Legionella, a waterborne pathogen, is the main cause of Legionnaires’ disease. Therefore, timely and accurate detection and differentiation of Legionella pneumophila and non -Legionella pneumophila species is crucial. In this study, we develop an easy and rapid recombinase polymerase amplification assay combined with EuNPs-based lateral flow immunochromatography (EuNPs-LFIC-RPA) to specifically distinguish Legionella pneumophila and non -Legionella pneumophila. We designed primers based on the mip gene of Legionella pneumophila and the 5S rRNA gene of non- Legionella pneumophila. The recombinase polymerase amplification reaction could go to completion in 10 min at 37°C, and the amplification products could be detected within 5 min with EuNPs-LFIC strips. Using a florescent test strip reader, the quantitative results were achieved by reading the colored signal intensities on the strips. The sensitivity was 1.6 × 10 1 CFU/ml, and a linear standard linear curve plotted from the test strip reader had a correlation coefficient for the determination of Legionella pneumophila ( R 2 = 0.9516). Completed concordance for the presence or absence of Legionella pneumophila by EuNPs-LFIC-RPA and qPCR was 97.32% ( κ = 0.79, 95% CI), according to an analysis of practical water samples ( n = 112). In short, this work shows the feasibility of EuNPs-LFIC-RPA for efficient and rapid monitoring of Legionella pneumophila and non- Legionella pneumophila in water samples.

          Related collections

          Most cited references54

          • Record: found
          • Abstract: found
          • Article: not found

          Loop-mediated isothermal amplification of DNA.

          T. Notomi (2000)
          We have developed a novel method, termed loop-mediated isothermal amplification (LAMP), that amplifies DNA with high specificity, efficiency and rapidity under isothermal conditions. This method employs a DNA polymerase and a set of four specially designed primers that recognize a total of six distinct sequences on the target DNA. An inner primer containing sequences of the sense and antisense strands of the target DNA initiates LAMP. The following strand displacement DNA synthesis primed by an outer primer releases a single-stranded DNA. This serves as template for DNA synthesis primed by the second inner and outer primers that hybridize to the other end of the target, which produces a stem-loop DNA structure. In subsequent LAMP cycling one inner primer hybridizes to the loop on the product and initiates displacement DNA synthesis, yielding the original stem-loop DNA and a new stem-loop DNA with a stem twice as long. The cycling reaction continues with accumulation of 10(9) copies of target in less than an hour. The final products are stem-loop DNAs with several inverted repeats of the target and cauliflower-like structures with multiple loops formed by annealing between alternately inverted repeats of the target in the same strand. Because LAMP recognizes the target by six distinct sequences initially and by four distinct sequences afterwards, it is expected to amplify the target sequence with high selectivity.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            DNA Detection Using Recombination Proteins

            Introduction The amplification of DNA is an essential step in most nucleic acid–based testing strategies. Established amplification techniques rely on sophisticated instrumentation, such as temperature-regulating equipment or complex sample-handling procedures. While unproblematic for specialised laboratories, these requirements have hampered the uptake of nucleic acid analyses in point-of-use and field settings. The technology presented in this study, recombinase polymerase amplification (RPA), overcomes the technical difficulties posed by current DNA amplification methods. It does not require thermal denaturation of template and operates at a low and constant temperature. In combination with a novel probe-based detection approach, RPA constitutes a significant advance in the development of portable and widely accessible nucleic acid–based tests. In RPA, the isothermal amplification of specific DNA fragments is achieved by the binding of opposing oligonucleotide primers to template DNA and their extension by a DNA polymerase ( Figure 1A). Global melting of the template is not required for the primers to be directed to their complementary target sequences. Instead, RPA employs recombinase-primer complexes to scan double-stranded DNA and facilitate strand exchange at cognate sites [ 1– 3]. The resulting structures are stabilised by single-stranded DNA binding proteins interacting with the displaced template strand, thus preventing the ejection of the primer by branch migration [ 4]. Recombinase disassembly leaves the 3′-end of the oligonucleotide accessible to a strand displacing DNA polymerase, in this case the large fragment of Bacillus subtilis Pol I (Bsu, [ 5]), and primer extension ensues. Exponential amplification is accomplished by the cyclic repetition of this process. The key to RPA is the establishment of a dynamic reaction environment that balances the formation and disassembly of recombinase-primer filaments ( Figure 1B). The recombinase we have employed, T4 uvsX, binds cooperatively to oligonucleotides in the presence of ATP. The resulting nucleoprotein complex actively hydrolyses ATP, and spontaneous recombinase disassembly in the ADP-bound state can lead to its replacement by T4 gp32, a single-stranded DNA binding protein necessary for the reaction. We found that a unique combination of T4 uvsY, a recombinase loading factor [ 6], and a particular crowding agent (Carbowax20M) establishes favourable reaction conditions that support RPA (see Protocol S1 and Figures S1 to S3). The proteins used in our approach are central components of in vivo processes required for cellular DNA synthesis, recombination, and repair and have been the subject of intensive research for a number of years [ 7]. In addition to facilitating DNA amplification in the RPA context, the dynamic reaction environment described here provides a system for the in vitro study of the recombination machinery and will aid the development of laboratory procedures that replace conventional hybridisation techniques. Results/Discussion We applied the RPA process to a wide variety of targets in complex DNA templates. The versatility and specificity of the technology are exemplified by the amplification of three genetic markers, apolipoprotein B (apoB), sex-determining region Y (Sry), and porphobilinogen deaminase (PBDG), from complex human genomic DNA ( Figure 2A). While the negative controls did not produce a signal, clean amplification products of the correct identity ( Figure S4) were generated in each template-containing sample. The progression of RPA reactions can be monitored in real-time by the inclusion of a sensitive nucleic acid dye ( Figure 2B) [ 8]. Here, primers for a locus in the B. subtilis genome have been used. The amplification of DNA proved to be exponential over a wide range of template concentrations and results were obtained in less than 30 min. The onset of amplification depends linearly on the logarithm of the starting number of template copies. Reactions carried out in the absence of template or at low template concentrations eventually generated a nonspecific signal, an effect brought about by a primer-dependent artefact ( Figure 2B, water control). To devise a highly sensitive RPA detection system that is not affected by primer artefacts, we developed a probe-based detection method ( Figure 3A). The probe we use contains a tetrahydrofuran abasic–site mimic (THF) [ 9], flanked in close proximity by nucleotides modified with a fluorophore and a quencher. The fluorescence of the intact construct is low. A block at the 3′-end prevents the oligonucleotide from acting as an amplification primer. Pairing of the probe to complementary DNA enables the recognition of the THF by the double-strand–specific Escherichia coli endonuclease IV (Nfo) [ 10]. The need for formation of a stable DNA duplex acts as an additional specificity-proofreading step in the context of our detection approach. Subsequent cutting of the probe separates the fluorophore/quencher complex and leads to a measurable increase in fluorescence. The cleavage reaction generates a free 3′ OH-end on the 5′ remnant of the incised probe. This oligomer can then be elongated by Bsu polymerase, thus serving as an amplification primer. To demonstrate the performance of combined RPA and probe/nuclease-based read-out, we designed primers and probes for the detection of the common hospital pathogen methicillin-resistant Staphylococcus aureus (MRSA; Figure 3B) [ 11]. The sensitivity and reproducibility of RPA were explored by the amplification of the staphylococcal cassette chromosome mec (SCC mec) integration locus of the isoform MRSAIII ( Figure 4A, see Protocol S1 for sequences). The onset of amplification at identical starting template quantities of ten, 100, 1,000, or 10,000 copies was virtually simultaneous, demonstrating the robustness of the technique. A plot of the time of beginning amplification against the logarithm of starting copy number reveals a linear relationship ( Figure 4B). At low template amounts (two copies), the amplification times are distributed over a wider period, with one reaction failing to generate a signal at all, and the correlation between onset of amplification and template concentration breaks down. However, product detection in samples with such low template concentrations supports the notion that RPA can essentially attain single template copy sensitivity. The high sensitivity and specificity of RPA allow the design of a multiplex approach in which different amplicons are generated and detected in the same reaction. Three polymorphic alleles of the SCC mec integration region represent the vast majority of known MRSA genotypes (MRSAI through III; Figure 5A) [ 12]. While they share the genomic locus orfX, they differ in the sequence of the SCC mec. The integrating elements of MRSAI and II are homologous to each other except for a 102–base-pair insertion/deletion, while the MRSAIII SCC mec is highly divergent. A primer shared by all alleles was designed for the common region (orfX), whereas primers specific for MRSAI/II and MRSAIII target the different SCC mec variants (sccI/II and III, respectively). To ensure detection of all three isoforms, we designed two highly homologous probes (to account for polymorphisms) for the common region (SATamra1 and SATamra2). Fusing the target sequences for the primers sccIII and orfX to an unrelated DNA sequence created an internal control for the reaction. To verify the activity of each sample, the amplification of this construct was monitored simultaneously with that of the MRSA targets using another probe of appropriate sequence and bearing a different fluorophore/quencher pair (BSFlc). We employed this combination of primers and probes to detected ten genomic copies of the three MRSA types ( Figure 5B). By contrast, the closely related methicillin-sensitive Staphylococcus aureus (MSSA; 10 4 copies) serving as a negative control did not generate a signal, despite being amplified by suitable primers (see Figure S5). The internal control was concomitantly detected in all samples. The combination of RPA and the described nuclease-sensitive fluorophore/quencher probes constitutes a DNA amplification/detection system that would require no other equipment than a simple handheld fluorometer, thus making quantitative DNA testing potentially accessible in a nonlaboratory point-of-care environment. We devised an even simpler detection approach by employing lateral-flow dipstick technology. This system is often used as a simple disposable diagnostic device. It employs pairs of specific antibodies to immobilise and detect entities containing two antigenic labels ( Figure 6A). Reaction mixtures (see below) are applied to a sample pad soaked in visible gold particles that are coupled to an antibody recognising one antigen. The complexes then travel in a buffer stream through the membrane and an additional, immobilised antibody captures the second antigen. If the antigens are conjoined in a DNA duplex, a coloured line appears at a defined location on the strip. A second line of immobilised antibodies captures the gold-conjugated antibody directly, whether conjoined to the other antigen or not, and serves as a flow control for the strip. In a variation of our probe detection system, we produced such dual antigen complexes by coupling biotin- and carboxyfluorescein (FAM)-bearing oligonucleotides in RPA amplicons ( Figure 6B). The 5′-biotinylated primer and its opposing counterpart ensure the efficient amplification of a target for probe binding. The probe, including a 5′-FAM label, an internal THF, and a 3′-blocking group, is incised by Nfo upon binding, creating a 3′ OH substrate for elongation by Bsu. The extension of the probe remnant stabilises its interaction with the biotin-labeled opposing strand and produces an amplicon that contains both antigens, biotin and FAM. The THF/3′ block prevents the production of biotin/FAM-containing primer artefacts, as processing of bona fide duplexes by Nfo adds a critical proofreading step. We used a multiplex approach similar to the one employed in Figure 5 to detect ten copies of each of the three MRSA isoforms and distinguish them from MSSA ( Figure 6C). As before, we designed two highly homologous probes (to account for polymorphisms) for the common region (Lfs1 and Lfs2). RPA reactions were followed by the application of the reaction mixtures to the sample pads of lateral-flow strips. Samples containing the MRSA template created biotin/FAM-amplicons and generated visible signals on the antibiotin detection line. In contrast, the MSSA-containing negative control failed to produce a conjoined complex and gave rise to the flow-control line only. A number of research and clinical applications could benefit from employing RPA. Perhaps most obviously, the technology offers a significant breakthrough for the development of nonlaboratory devices. When integrated with handheld instruments or entirely equipment-free DNA detection systems, RPA will enable an easy-to-use testing system for a variety of pathogens as well as field kits for other applications. Materials and Methods Proteins and DNA. Coding sequences for uvsx, uvsy, gp32, Bsu, and Nfo were amplified from genomic DNA (DSMZ, Braunschweig Germany), fused to hexahistidine-tags (N-terminal for uvsY, Bsu, and Nfo, C-terminal for uvsX and gp32), and cloned into suitable expression vectors. Overexpression and purification were done by standard protocols using nickel-NTA resin (Qiagen, Valencia, California, United States). Human genomic DNA was from Promega (Madison, Wisconsin, United States), B. subtilis DNA was from ATCC (American Type Culture Collection, Manassas, Virginia, United States), and S. aureus DNAs were a gift from Jodi Lindsay (University of London, London, England). S. aureus strains were EMRSA-3 (SCC mec type I; MRSAI), EMRSA-16 (MRSAII), EMRSA-1 (MRSAIII), and wild-type MSSA. RPA conditions. Reactions were performed at 37 °C for 60 min or as indicated. Standard conditions were 50 mM Tris (pH 7.9), 100 mM potassium acetate, 14 mM magnesium acetate, 2 mM DTT, 5% Carbowax20M, 200 μM dNTPs, 3 mM ATP, 50 mM phosphocreatine, 100 ng/μl creatine kinase, and 30 ng/μl Bsu; in the multiplex experiment, Carbowax20M was at 5.5%. Recombinase protein concentrations were 900 ng/μl gp32, 120 ng/μl uxsX, and 30 ng/μl uvsY. Primers used for amplification of human targets were apoB4, apoB300, sry3, sry4, pbdg5, pbdg6 (300 nM each), for B. subtilis, bs1 and bs2 were used (300 nM each) in the experiment in Figure 2B. For MRSA amplification, primers used were 500 nM sccIII, 100 nM orfX ( Figure 4A) or 265 nM sccI/II, 265 nM sccIII, 70 nM orfX ( Figure 5) or 240 nM Bio-sccI/II, 240 nM Bio-sccIII, 120 nM orfX ( Figure 6). Reaction volumes were 20 μl, except for the experiment shown in Figure 2A (40 μl). Real-time monitoring. Real-time RPA was performed in a plate-reader (Flx-800; BioTek, Winooski, Vermont, United States) in the presence of SybrGreenI (1:50,000; Molecular Probes, Eugene, Oregon, United States) or fluorophore/quencher probes (Eurogentec, San Diego, California, United States). Three probes were used: SATamra1 5′-tgttaattgaacaagtgtacagagcatt(T)a(H)ga(q1)tatgcgtggag-biotin-3′ SATamra2 5′-tgttaattgagcaagtgtatagagcatt(T)a(H)ga(q2)tatgcgtggag-biotin-3′ BSFlc 5′-catgattggatgaataagctgcagc(F)g(H)t(q3)aaaggaaactta-biotin-3′ Here, (T) is dT-TAMRA, (F) is dT-fluorescein, (H) is THF, (q1) is dT-BHQ1, (q2) is dT-BHQ2, and (q3) is dT-DDQ1. Probes were used at 60 nM SATamra1 (MRSAIII experiment) or at 45 nM SATamra1, 45 nM SATamra2, 60 nM BSFlc (multiplex experiment). Nfo was used at 200 ng/μl. Excitation/detection was at 485/525 nm (SybrGreenI, BSFlc) or 530/575 nm (SATamra1/2). Measurements were taken every 30 or 45 s (multiplex experiment). Fluorescence probe data were normalised (subtraction of water control average) and preamplification baseline adjusted. The logarithm of the read-out was plotted against reaction time. Lateral-flow strip detection. For lateral-flow strip experiments, two probes were used at 75 nM each: Lfs1 5′-FAM-ccacatcaaatgatgcgggttgtgttaat(H)gaacaagtgtacagag-ddC-3′ Lfs2 5′-FAM-ccacatcaaatgatgcgggttgtgttaat(H)gagcaagtgtatagag-ddC-3′ The 5′-biotinylated forms of sccI/II and sccIII were utilised as primers. For each reaction (20 μl), 1 μl was diluted with 5 μl of running buffer (PBS/3% Tween) and applied directly to HybriDetect strips (Milenia Biotec, Bad Nauheim, Germany) according to the manufacturer's instructions. Supporting Information Figure S1 Titrations of Reaction Components to Determine Conditions that Support RPA Polyacrylamide gel electrophoresis of RPA reactions using primers for the human Sry locus. Reactions were performed at 37 °C for 120 min and contained the primers sry3 and sry4 at 300 nM, 50 mM Tris (pH 8.4), 80 mM potassium acetate, 10 mM magnesium acetate, 2 mM DTT, 3 mM ATP, 200 μM dNTPs, 20 mM phosphocreatine, 100 ng/μl creatine kinase, 5% Carbowax20M, 600 ng/μl gp32, 200 ng/μl uvsX, 60 ng/μl uvsY, and 30 ng/μl Bsu, except when a given component was that under investigation. Optimal quantities of (A) gp32, (B) uvsY, (C) uvsX, (D) Carbowax20M, (E) ATP, and (F) Bsu for effective amplification of this particular target were determined. G) ADP-β-S and (H) ATP-γ-S inhibit the reactions. And 1,500 copies/μl of the human Y-chromosomal DNA served as template in 30-μl reactions (per sample the equivalent of 10-μl reaction volume was loaded on the gel). (159 KB PDF) Click here for additional data file. Figure S2 Investigation of Product Size Limits of RPA Agarose gel electrophoresis of RPA reactions using primers for the human apoB locus. Primer apoB4 was combined with opposing primers capable of generating products of the indicated sizes. Reactions were performed at 37 °C for 120 min, and conditions used were 50 mM Tris (pH 8.4), 80 mM potassium acetate, 10 mM magnesium acetate, 2 mM DTT, 3 mM ATP, 200 μM dNTPs, 20 mM phosphocreatine, 100 ng/μl creatine kinase, 5% Carbowax20M, 600 ng/μl gp32, 125 ng/μl uvsX, 25 ng/μl uvsY, and 30 ng/μl Bsu. And 450 copies of human DNA were used as template in 30-μl reactions (per sample the equivalent of 10-μl reaction volume was loaded on the gel). Note that some hairpin-mediated product duplication occurred, converting some of the 300–base-pair amplicon to 2× and 3× unit length (*). RPA failed to produce amplicons of 1,500 base-pairs or more. (70 KB PDF) Click here for additional data file. Figure S3 Investigation of the Minimum Oligonucleotides Size Necessary to Support RPA Polyacrylamide gel electrophoresis of RPA reactions using primers for the three independent loci in human genomic DNA (apoB, D18S51, Sry). Primers were 25, 28, or greater than 31 bases, as indicated. Reactions were performed at 37 °C for 120 min. Conditions used were 50 mM Tris/Cl (pH 8.4), 80 mM potassium acetate, 10 mM magnesium acetate, 2 mM DTT, 3 mM ATP, 200 μM dNTPs, 20 mM phosphocreatine, 100 ng/μl creatine kinase, 5% Carbowax20M, 600 ng/μl gp32, 200 ng/μl uvsX, 60 ng/μl uvsY, and 30 ng/μl Bsu polymerase. And 3,000 copies of target served as template in 30-μl reactions (per sample the equivalent of 10-μl reaction volume was loaded on the gel). The finding that a primer length of greater than 28 bases is required to support RPA is in good agreement with reports that investigated the ATP hydrolysis activity of uvsX-oligonucleotide filaments at different oligonucleotide sizes [ 3]. (17 KB PDF) Click here for additional data file. Figure S4 Restriction Digest of RPA Products Agarose gel electrophoresis of RPA reactions and their digestion products. Primers for the human loci apoB (primers apoB4, apoB300), Sry (primers sry3, sry4), and PBDG (primers pbdg5, pbdg6) were used. Reactions were performed at 37 °C for 60 min, and conditions used were 50 mM Tris (pH 7.9), 100 mM potassium acetate, 14 mM magnesium acetate, 2 mM DTT, 5% Carbowax20M, 200 μM dNTPs, 3 mM ATP, 300 nM each primer, 50 mM phosphocreatine, 100 ng/μl creatine kinase, and 30 ng/μl Bsu. Recombinase protein concentrations were 900 ng/μl gp32, 120 ng/μl uxsX, and 30 ng/μl uvsY. And 1,000 copies of human genomic DNA served as template. Reactions were performed in 40-μl volumes and purified using GenElute Clean-Up kits (Sigma, St. Louis, Missouri, United States). Ten percent of each reaction (equivalent to 4-μl RPA reaction) was either loaded directly (uncut) or after digestion with XbaI (apoB and Sry), HaeIII (apoB), or SmaI (PBDG) on a 2% agarose gel. The restriction pattern confirms the identity of the amplicons. Note that the amplicon generated by apoB4 and apoB300 includes an SNP covering the XbaI site. Since the template used is a combination of genomic DNA from several donors (Promega), the apoB RPA product consists of a mixture of fragments that either contain an XbaI site or are refractory to XbaI digestion. (92 KB PDF) Click here for additional data file. Figure S5 Probe Signal of RPA Reactions Using the Primer Set orfX/MSSA and Probe SATamra2 (A) MSSA DNA at 10 4 (black, reactions 1–3), 10 3 (red, 4–6), 100 (yellow, 7–9), ten (green, 10–12), or two (purple, 13–17) copies or MRSAI DNA at 10 4 copies (gray, reactions 18–20) or water (blue, 21–23) served as template. Reaction conditions were 50 mM Tris (pH 7.9), 100 mM potassium acetate, 14 mM magnesium acetate, 2 mM DTT, 200 μM dNTPs, 3 mM ATP, 20 mM phosphocreatine, 100 ng/μl creatine kinase, 5% Carbowax20M, 900 ng/μl gp32, 120 ng/μl uvsX, 30 ng/μl uvsY, and 30 ng/μl Bsu. Oligonucleotides were used at 500 nM MSSA, 100 nM orfX, and 60 nM SATamra2. While the MSSA target is amplified even at very low concentrations, the negative control (MRSAI) does not generate a signal. (B) A plot of the onset time of amplification (defined as passing the 2.5 threshold) in reactions 1 to 12 against the logarithm of the template copy number reveals a linear relationship. (53 KB PDF) Click here for additional data file. Protocol S1 Primer Sequences, Sequences of MRSA/MSSA Alleles, RPA Conditions, Primer Requirements, and Control DNA (32 KB DOC) Click here for additional data file. Accession Numbers The National Center for Biotechnology Information (NCBI) ( http://www.ncbi.nlm.nih.gov) accession numbers used in this paper are Bsu (NP_390787), T4 uvsX (NP_049656) T4 gp32 (NP_049854), T4 uvsY (NP_049799), apoB (AY324608), Sry (NM_003140), PBDG (AP003391), and Nfo (AP_002756) and SNP (SNP-ID rs693).
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Isothermal Amplification of Nucleic Acids.

              Isothermal amplification of nucleic acids is a simple process that rapidly and efficiently accumulates nucleic acid sequences at constant temperature. Since the early 1990s, various isothermal amplification techniques have been developed as alternatives to polymerase chain reaction (PCR). These isothermal amplification methods have been used for biosensing targets such as DNA, RNA, cells, proteins, small molecules, and ions. The applications of these techniques for in situ or intracellular bioimaging and sequencing have been amply demonstrated. Amplicons produced by isothermal amplification methods have also been utilized to construct versatile nucleic acid nanomaterials for promising applications in biomedicine, bioimaging, and biosensing. The integration of isothermal amplification into microsystems or portable devices improves nucleic acid-based on-site assays and confers high sensitivity. Single-cell and single-molecule analyses have also been implemented based on integrated microfluidic systems. In this review, we provide a comprehensive overview of the isothermal amplification of nucleic acids encompassing work published in the past two decades. First, different isothermal amplification techniques are classified into three types based on reaction kinetics. Then, we summarize the applications of isothermal amplification in bioanalysis, diagnostics, nanotechnology, materials science, and device integration. Finally, several challenges and perspectives in the field are discussed.
                Bookmark

                Author and article information

                Contributors
                Journal
                Front Chem
                Front Chem
                Front. Chem.
                Frontiers in Chemistry
                Frontiers Media S.A.
                2296-2646
                07 February 2022
                2021
                : 9
                : 815189
                Affiliations
                Zhejiang Provincial Key Laboratory of Biometrology and Inspection and Quarantine , China Jiliang University , Hangzhou, China
                Author notes

                Edited by: Shou-Nian Ding, Southeast University, China

                Reviewed by: Shouyu Wang, Jiangnan University, China

                Rajesh Paul, North Carolina State University, United States

                *Correspondence: Mingzhou Zhang, zmzcjlu@ 123456cjlu.edu.cn
                [ † ]

                These authors have contributed equally to this work

                This article was submitted to Analytical Chemistry, a section of the journal Frontiers in Chemistry

                Article
                815189
                10.3389/fchem.2021.815189
                8859533
                35198541
                d900270b-0f89-4934-84aa-b4976264e02c
                Copyright © 2022 Du, Ma, Li, Wang, Dou, Xu and Zhang.

                This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.

                History
                : 15 November 2021
                : 28 December 2021
                Funding
                Funded by: National Key Research and Development Program of China , doi 10.13039/501100012166;
                Award ID: 2021YFF0602801
                Categories
                Chemistry
                Original Research

                fluorescent immunochromatographic assay,recombinase polymerase amplification,europium nanoparticles,legionella pneumophila,simultaneous detection

                Comments

                Comment on this article