      Self-Expanding Coronary Stent (Radius) Implantation with Cutting Balloon Angioplasty

      Read this article at

      ScienceOpenPublisherPubMed
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          To evaluate the effect of cutting balloon (CB) angioplasty on the outcome of self-expanding coronary stent implantation, we compared the results of Radius stent implantation using two predilation strategies. Seventy de novo lesions in 70 patients (60 men) were included in the study. Stenting was performed after conventional angioplasty (n = 38, group 1) or CB angioplasty (n = 32, group 2). In-stent restenosis (ISR) rates of each group were 39 and 10% at 6-month follow-up (p = 0.02). Major adverse cardiac events occurred in 20 and 11%, respectively (p = 0.25). Multivariate analysis revealed that ISR was predicted only by lesion length ≧20 mm. In conclusion, CB angioplasty did not reduce ISR after Radius stent implantation, when other independent risk factors, such as lesion length, were taken into consideration.

          Related collections

          Most cited references 12

          • Record: found
          • Abstract: found
          • Article: not found

          Restenosis and the proportional neointimal response to coronary artery injury: results in a porcine model.

          Restenosis is a reparative response to arterial injury occurring with percutaneous coronary revascularization. However, the quantitative characteristics of the relation between vessel injury and the magnitude of restenotic response remain unknown. This study was thus performed to determine the relation between severity of vessel wall injury and the thickness of resulting neointimal proliferation in a porcine model of coronary restenosis. Twenty-six porcine coronary artery segments in 24 pigs were subjected to deep arterial injury with use of overexpanded, percutaneously delivered tantalum wire coils. The vessels were studied microscopically 4 weeks after coil implantation to measure the relation between the extent of injury and the resulting neointimal thickness. For each wire site, a histopathologic score proportional to injury depth and the neointimal thicknesses at that site were determined. Mean injury scores were compared with both mean neointimal thickness and planimetry-derived area percent lumen stenosis. The severity of vessel injury strongly correlated with neointimal thickness and percent diameter stenosis (p less than 0.001). Neointimal proliferation resulting from a given wire was related to injury severity in adjacent wires, suggesting an interaction among effects at injured sites. If the results in this model apply to human coronary arteries, restenosis may depend on the degree of vessel injury sustained during angioplasty.
            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            Cutting balloon: a novel approach to percutaneous angioplasty.

              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Cutting balloon angioplasty for the prevention of restenosis: results of the Cutting Balloon Global Randomized Trial

              The cutting balloon (CB) is a specialized device designed to create discrete longitudinal incisions in the atherosclerotic target coronary segment during balloon inflation. Such controlled dilatation theoretically reduces the force needed to dilate an obstructive lesion compared with standard percutaneous transluminal coronary angioplasty (PTCA). We report a multicenter, randomized trial comparing the incidence of restenosis after CB angioplasty versus conventional balloon angioplasty in 1,238 patients. Six hundred seventeen patients were randomized to CB treatment, and 621 to PTCA. The mean reference vessel diameter was 2.86 +/- 0.49 mm, mean lesion length 8.9 +/- 4.3 mm, and prevalence of diabetes mellitus in patients was 13%. The primary end point, the 6-month binary angiographic restenosis rate, was 31.4% for CB and 30.4% for PTCA (p = 0.75). Acute procedural success, defined as the attainment of <50% diameter stenosis without in-hospital major adverse cardiac events, was 92.9% for CB and 94.7% for PTCA (p = 0.24). Freedom from target vessel revascularization was slightly higher in the CB arm (88.5% vs 84.6%, log-rank p = 0.04). Five coronary perforations occurred in the CB arm only (0.8% vs 0%, p = 0.03). At 270 days, rates of myocardial infarction, death, and total major adverse cardiac events for CB and PTCA were 4.7% versus 2.4% (p = 0.03), 1.3% versus 0.3% (p = 0.06), and 13.6% versus 15.1% (p = 0.34), respectively. In summary, the proposed mechanism of controlled dilatation did not reduce the rate of angiographic restenosis for the CB compared with conventional balloon angioplasty. CB angioplasty should be reserved for difficult lesions in which controlled dilatation is believed to provide a better acute result compared with balloon angioplasty alone.
                Bookmark

                Author and article information

                Journal
                CRD
                Cardiology
                10.1159/issn.0008-6312
                Cardiology
                S. Karger AG
                0008-6312
                1421-9751
                2005
                April 2005
                07 April 2005
                : 103
                : 3
                : 123-127
                Affiliations
                aDepartment of Internal Medicine, Kangnam Sacred Heart Hospital, Hallym University College of Medicine, and bCardiology Division, Yonsei Cardiovascular Center and Cardiovascular Research Institute, Yonsei University College of Medicine, Seoul, Korea
                Article
                83437 Cardiology 2005;103:123–127
                10.1159/000083437
                15665533
                © 2005 S. Karger AG, Basel

                Copyright: All rights reserved. No part of this publication may be translated into other languages, reproduced or utilized in any form or by any means, electronic or mechanical, including photocopying, recording, microcopying, or by any information storage and retrieval system, without permission in writing from the publisher. Drug Dosage: The authors and the publisher have exerted every effort to ensure that drug selection and dosage set forth in this text are in accord with current recommendations and practice at the time of publication. However, in view of ongoing research, changes in government regulations, and the constant flow of information relating to drug therapy and drug reactions, the reader is urged to check the package insert for each drug for any changes in indications and dosage and for added warnings and precautions. This is particularly important when the recommended agent is a new and/or infrequently employed drug. Disclaimer: The statements, opinions and data contained in this publication are solely those of the individual authors and contributors and not of the publishers and the editor(s). The appearance of advertisements or/and product references in the publication is not a warranty, endorsement, or approval of the products or services advertised or of their effectiveness, quality or safety. The publisher and the editor(s) disclaim responsibility for any injury to persons or property resulting from any ideas, methods, instructions or products referred to in the content or advertisements.

                Page count
                Tables: 4, References: 16, Pages: 5
                Categories
                Cardiac Catheterization and Interventional Cardiology

                Comments

                Comment on this article