      Gesture recognition by instantaneous surface EMG images

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Gesture recognition in non-intrusive muscle-computer interfaces is usually based on windowed descriptive and discriminatory surface electromyography (sEMG) features because the recorded amplitude of a myoelectric signal may rapidly fluctuate between voltages above and below zero. Here, we present that the patterns inside the instantaneous values of high-density sEMG enables gesture recognition to be performed merely with sEMG signals at a specific instant. We introduce the concept of an sEMG image spatially composed from high-density sEMG and verify our findings from a computational perspective with experiments on gesture recognition based on sEMG images with a classification scheme of a deep convolutional network. Without any windowed features, the resultant recognition accuracy of an 8-gesture within-subject test reached 89.3% on a single frame of sEMG image and reached 99.0% using simple majority voting over 40 frames with a 1,000 Hz sampling rate. Experiments on the recognition of 52 gestures of NinaPro database and 27 gestures of CSL-HDEMG database also validated that our approach outperforms state-of-the-arts methods. Our findings are a starting point for the development of more fluid and natural muscle-computer interfaces with very little observational latency. For example, active prostheses and exoskeletons based on high-density electrodes could be controlled with instantaneous responses.

          Related collections

          Most cited references16

          • Record: found
          • Abstract: found
          • Article: found
          Is Open Access

          Electromyography data for non-invasive naturally-controlled robotic hand prostheses

          Recent advances in rehabilitation robotics suggest that it may be possible for hand-amputated subjects to recover at least a significant part of the lost hand functionality. The control of robotic prosthetic hands using non-invasive techniques is still a challenge in real life: myoelectric prostheses give limited control capabilities, the control is often unnatural and must be learned through long training times. Meanwhile, scientific literature results are promising but they are still far from fulfilling real-life needs. This work aims to close this gap by allowing worldwide research groups to develop and test movement recognition and force control algorithms on a benchmark scientific database. The database is targeted at studying the relationship between surface electromyography, hand kinematics and hand forces, with the final goal of developing non-invasive, naturally controlled, robotic hand prostheses. The validation section verifies that the data are similar to data acquired in real-life conditions, and that recognition of different hand tasks by applying state-of-the-art signal features and machine-learning algorithms is possible.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Support vector machine-based classification scheme for myoelectric control applied to upper limb.

            This paper proposes and evaluates the application of support vector machine (SVM) to classify upper limb motions using myoelectric signals. It explores the optimum configuration of SVM-based myoelectric control, by suggesting an advantageous data segmentation technique, feature set, model selection approach for SVM, and postprocessing methods. This work presents a method to adjust SVM parameters before classification, and examines overlapped segmentation and majority voting as two techniques to improve controller performance. A SVM, as the core of classification in myoelectric control, is compared with two commonly used classifiers: linear discriminant analysis (LDA) and multilayer perceptron (MLP) neural networks. It demonstrates exceptional accuracy, robust performance, and low computational load. The entropy of the output of the classifier is also examined as an online index to evaluate the correctness of classification; this can be used by online training for long-term myoelectric control operations.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              The optimal controller delay for myoelectric prostheses.

              A tradeoff exists when considering the delay created by multifunctional prosthesis controllers. Large controller delays maximize the amount of time available for EMG signal collection and analysis (and thus maximize classification accuracy); however, large delays also degrade prosthesis performance by decreasing the responsiveness of the prosthesis. To elucidate an "optimal controller delay" twenty able-bodied subjects performed the Box and Block Test using a device called PHABS (prosthetic hand for able bodied subjects). Tests were conducted with seven different levels of controller delay ranging from nearly 0-300 ms and with two different artificial hand speeds. Based on repeted measures ANOVA analysis and a linear mixed effects model, the optimal controller delay was found to range between approximately 100 ms for fast prehensors and 125 ms for slower prehensors. Furthermore, the linear mixed effects model shows that there is a linear degradation in performance with increasing delay.
                Bookmark

                Author and article information

                Journal
                Sci Rep
                Sci Rep
                Scientific Reports
                Nature Publishing Group
                2045-2322
                15 November 2016
                2016
                : 6
                : 36571
                Affiliations
                [1 ]Zhejiang University, College of Computer Science , Hangzhou, 310027, China
                Author notes
                Article
                srep36571
                10.1038/srep36571
                5109222
                27845347
                da6461c1-deb4-469f-9451-c55fc2179a5c
                Copyright © 2016, The Author(s)

                This work is licensed under a Creative Commons Attribution 4.0 International License. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in the credit line; if the material is not included under the Creative Commons license, users will need to obtain permission from the license holder to reproduce the material. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/

                History
                : 01 June 2016
                : 17 October 2016
                Categories
                Article

                Uncategorized
                Uncategorized

                Comments

                Comment on this article