      Improved cardiovascular diagnostic accuracy by pocket size imaging device in non-cardiologic outpatients: the NaUSiCa (Naples Ultrasound Stethoscope in Cardiology) study

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Miniaturization has evolved in the creation of a pocket-size imaging device which can be utilized as an ultrasound stethoscope. This study assessed the additional diagnostic power of pocket size device by both experts operators and trainees in comparison with physical examination and its appropriateness of use in comparison with standard echo machine in a non-cardiologic population.

          Three hundred four consecutive non cardiologic outpatients underwent a sequential assessment including physical examination, pocket size imaging device and standard Doppler-echo exam. Pocket size device was used by both expert operators and trainees (who received specific training before the beginning of the study). All the operators were requested to give only visual, qualitative insights on specific issues. All standard Doppler-echo exams were performed by expert operators.

          One hundred two pocket size device exams were performed by experts and two hundred two by trainees. The time duration of the pocket size device exam was 304 ± 117 sec. Diagnosis of cardiac abnormalities was made in 38.2% of cases by physical examination and in 69.7% of cases by physical examination + pocket size device (additional diagnostic power = 31.5%, p < 0.0001). The overall K between pocket size device and standard Doppler-echo was 0.67 in the pooled population (0.84 by experts and 0.58 by trainees). K was suboptimal for trainees in the eyeball evaluation of ejection fraction, left atrial dilation and right ventricular dilation. Overall sensitivity was 91% and specificity 76%. Sensitivity and specificity were lower in trainees than in experts.

          In conclusion, pocket size device showed a relevant additional diagnostic value in comparison with physical examination. Sensitivity and specificity were good in experts and suboptimal in trainees. Specificity was particularly influenced by the level of experience. Training programs are needed for pocket size device users.

          Related collections

          Most cited references20

          • Record: found
          • Abstract: not found
          • Article: not found

          Echocardiographic assessment of valve stenosis: EAE/ASE recommendations for clinical practice.

            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            European Association of Echocardiography recommendations for the assessment of valvular regurgitation. Part 1: aortic and pulmonary regurgitation (native valve disease).

            Valvular regurgitation represents an important cause of cardiovascular morbidity and mortality. Echocardiography has become the primary non-invasive imaging method for the evaluation of valvular regurgitation. The echocardiographic assessment of valvular regurgitation should integrate quantification of the regurgitation, assessment of the valve anatomy, and function as well as the consequences of valvular disease on cardiac chambers. In clinical practice, the management of patients with valvular regurgitation thus largely integrates the results of echocardiography. It is crucial to provide standards that aim at establishing a baseline list of measurements to be performed when assessing regurgitation.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              European Association of Echocardiography recommendations for training, competence, and quality improvement in echocardiography.

              The main mission statement of the European Association of Echocardiography (EAE) is 'to promote excellence in clinical diagnosis, research, technical development, and education in cardiovascular ultrasound in Europe'. As competence and quality control issues are increasingly recognized by patients, physicians, and payers, the EAE has established recommendations for training, competence, and quality improvement in echocardiography. The purpose of this document is to provide the requirements for training and competence in echocardiography, to outline the principles of quality measurement, and to recommend a set of measures for improvement, with the ultimate goal of raising the standards of echocardiographic practice in Europe.
                Bookmark

                Author and article information

                Journal
                Cardiovasc Ultrasound
                Cardiovascular Ultrasound
                BioMed Central
                1476-7120
                2010
                26 November 2010
                : 8
                : 51
                Affiliations
                [1 ]Department of Clinical and Experimental Medicine, Federico II University Hospital, Naples, Italy
                Article
                1476-7120-8-51
                10.1186/1476-7120-8-51
                3003628
                21110840
                dab6d186-3742-4210-a37c-50e0f6c67156
                Copyright ©2010 Galderisi et al; licensee BioMed Central Ltd.

                This is an Open Access article distributed under the terms of the Creative Commons Attribution License ( http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

                History
                : 7 November 2010
                : 26 November 2010
                Categories
                Research

                Cardiovascular Medicine
                Cardiovascular Medicine

                Comments

                Comment on this article