      Prospectively Electrocardiogram-Gated High-Pitch Spiral Acquisition Mode Dual-Source CT Coronary Angiography in Patients with High Heart Rates: Comparison with Retrospective Electrocardiogram-Gated Spiral Acquisition Mode

      research-article

      Read this article at

      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          Objective

          To assess the image quality and effective radiation dose of prospectively electrocardiogram (ECG)-gated high-pitch spiral acquisition mode (flash mode) of dual-source CT (DSCT) coronary angiography (CTCA) in patients with high heart rates (HRs) as compared with retrospectively ECG-gated spiral acquisition mode.

          Materials and Methods

          Two hundred and sixty-eight consecutive patients (132 female, mean age: 55 ± 11 years) with mean HR > 65 beats per minute (bpm) were prospectively included in this study. The patients were divided into two groups. Collection was performed in group A CTCA using flash mode setting at 20-30% of the R-R interval, and retrospectively ECG-gated spiral acquisition mode in group B. The image noise, contrast-to-noise ratio (CNR), image quality scores, effective radiation dose and influencing factors on image quality between the two groups were assessed.

          Results

          There were no significant differences in image quality scores and proportions of non-diagnostic coronary artery segments between two groups (image quality scores: 1.064 ± 0.306 [group A] vs. 1.084 ± 0.327 [group B], p = 0.063; proportion of non-diagnostic coronary artery segments: segment-based analysis 1.52% (group A) vs. 1.74% (group B), p = 0.345; patient-based analysis 7.5% (group A) vs. 6.7% (group B), p = 0.812). The estimated radiation dose was 1.0 ± 0.16 mSv in group A and 7.1 ± 1.05 mSv in group B ( p = 0.001).

          Conclusion

          In conclusion, in patients with HRs > 65 bpm without cardiac arrhythmia, the prospectively high-pitch spiral-acquisition mode with image-acquired timing set at 20-30% of the R-R interval provides a similar image quality and low rate of non-diagnostic coronary segments to the retrospectively ECG-gated low-pitch spiral acquisition mode, with significant reduction of radiation exposure.

          Related collections

          Most cited references38

          • Record: found
          • Abstract: found
          • Article: not found

          Diagnostic accuracy of noninvasive coronary angiography using 64-slice spiral computed tomography.

          The aim of our study was to evaluate the diagnostic accuracy of multislice computed tomography (MSCT) coronary angiography using a new 64-slice scanner. The new 64-slice MSCT scanner has improved spatial resolution of 0.4 mm and a faster rotation time (330 ms) compared to prior MSCT scanners. We studied 70 consecutive patients undergoing elective invasive coronary angiography. Patients were excluded for atrial fibrillation, but not for high heart rate, coronary calcification, or obesity. All vessels were analyzed, including those 70 beats/min, and 50% were obese. Specificity, sensitivity, and positive and negative predictive values for the presence of significant stenoses were: by segment (n = 935), 86%, 95%, 66%, and 98%, respectively; by artery (n = 279), 91%, 92%, 80%, and 97%, respectively; by patient (n = 70), 95%, 90%, 93%, and 93%, respectively. Our results indicate high quantitative and qualitative diagnostic accuracy of 64-slice MSCT in comparison to QCA in a broad spectrum of patients.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Prospectively gated transverse coronary CT angiography versus retrospectively gated helical technique: improved image quality and reduced radiation dose.

            To retrospectively compare image quality, radiation dose, and blood vessel assessability for coronary artery computed tomographic (CT) angiograms obtained with a prospectively gated transverse (PGT) CT technique and a retrospectively gated helical (RGH) CT technique. This HIPAA-compliant study received a waiver for approval from the institutional review board, including one for informed consent. Coronary CT angiograms obtained with 64-detector row CT were retrospectively evaluated in 203 clinical patients. A routine RGH technique was evaluated in 82 consecutive patients (44 males, 38 females; mean age, 55.6 years). The PGT technique was then evaluated in 121 additional patients (71 males, 50 females; mean age, 56.7 years). All images were evaluated for image quality, estimated radiation dose, and coronary artery segment assessability. Differences in image quality score were evaluated by using a proportional odds logistic regression model, with main effects for three readers, two techniques, and four arteries. The mean effective dose for the group with the PGT technique was 2.8 mSv; this represents an 83% reduction as compared with that for the group with the RGH technique (mean, 18.4 mSv; P < .001). The image quality score for each of the arteries, as well as the overall combined score, was significantly greater for images obtained with PGT technique than for images obtained with RGH technique. The combined mean image quality score was 4.791 for images obtained with PGT technique versus 4.514 for images obtained with RGH technique (proportional odds model odds ratio, 2.8; 95% confidence interval: 1.7, 4.8). The percentage of assessable coronary artery segments was 98.6% (1196 of 1213) for images obtained with PGT technique versus 97.9% (1741 of 1778) for images obtained with RGH technique (P = .83). PGT coronary CT angiography offers improved image quality and substantially reduced effective radiation dose compared with traditional RGH coronary CT angiography. (c) RSNA, 2008.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Feasibility of low-dose coronary CT angiography: first experience with prospective ECG-gating.

              To determine the feasibility of prospective electrocardiogram (ECG)-gating to achieve low-dose computed tomography coronary angiography (CTCA). Forty-one consecutive patients with suspected (n = 35) or known coronary artery disease (n = 6) underwent 64-slice CTCA using prospective ECG-gating. Individual radiation dose exposure was estimated from the dose-length product. Two independent readers semi-quantitatively assessed the overall image quality on a five-point scale and measured vessel attenuation in each coronary segment. One patient was excluded for atrial fibrillation. Mean effective radiation dose was 2.1 +/- 0.6 mSv (range, 1.1-3.0 mSv). Image quality was inversely related to heart rate (HR) (57.3 +/- 6.2, range 39-66 b.p.m.; r = 0.58, P 63 b.p.m. (P < 0.001). This first experience documents the feasibility of prospective ECG-gating for CTCA with diagnostic image quality at a low radiation dose (1.1-3.0 mSv), favouring HR <63 b.p.m.
                Bookmark

                Author and article information

                Journal
                Korean J Radiol
                Korean J Radiol
                KJR
                Korean Journal of Radiology
                The Korean Society of Radiology
                1229-6929
                2005-8330
                Nov-Dec 2012
                12 October 2012
                : 13
                : 6
                : 684-693
                Affiliations
                [1 ]Department of Radiology, Baotou Central Hospital, Baotou 014040, China.
                [2 ]Department of Cardiology, Baotou Central Hospital, Baotou 014040, China.
                [3 ]CT BM Clinic Marketing, Siemens Healthcare, Beijing 100102, China.
                Author notes
                Corresponding author: Kai Sun, MD, Department of Radiology, Baotou Central Hospital, Inner Mongolia, Donghe Street, Baotou 014040, China. Tel: (86)013654844693, Fax: (86)04726955002, henrysk@ 123456163.com
                Article
                10.3348/kjr.2012.13.6.684
                3484288
                23118566
                dc9de0fc-8f59-485d-9d7c-188b89286acc
                Copyright © 2012 The Korean Society of Radiology

                This is an Open Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License ( http://creativecommons.org/licenses/by-nc/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.