      Incorporation of a laser range scanner into image-guided liver surgery: Surface acquisition, registration, and tracking

      Read this article at

      ScienceOpenPublisherPMC
      Bookmark
          There is no author summary for this article yet. Authors can add summaries to their articles on ScienceOpen to make them more accessible to a non-specialist audience.

          Abstract

          As image guided surgical procedures become increasingly diverse, there will be more scenarios where point-based fiducials cannot be accurately localized for registration and rigid body assumptions no longer hold. As a result, procedures will rely more frequently on anatomical surfaces for the basis of image alignment and will require intraoperative geometric data to measure and compensate for tissue deformation in the organ. In this paper we outline methods for which a laser range scanner may be used to accomplish these tasks intraoperatively. A laser range scanner based on the optical principle of triangulation acquires a dense set of three-dimensional point data in a very rapid, noncontact fashion. Phantom studies were performed to test the ability to link range scan data with traditional modes of image-guided surgery data through localization, registration, and tracking in physical space. The experiments demonstrate that the scanner is capable of localizing point-based fiducials to within 0.2 mm and capable of achieving point and surface based registrations with target registration error of less than 2.0 mm. Tracking points in physical space with the range scanning system yields an error of 1.4 +/- 0.8 mm. Surface deformation studies were performed with the range scanner in order to determine if this device was capable of acquiring enough information for compensation algorithms. In the surface deformation studies, the range scanner was able to detect changes in surface shape due to deformation comparable to those detected by tomographic image studies. Use of the range scanner has been approved for clinical trials, and an initial intraoperative range scan experiment is presented. In all of these studies, the primary source of error in range scan data is deterministically related to the position and orientation of the surface within the scanner's field of view. However, this systematic error can be corrected, allowing the range scanner to provide a rapid, robust method of acquiring anatomical surfaces intraoperatively.

          Related collections

          Most cited references25

          • Record: found
          • Abstract: not found
          • Article: not found

          General Theory of Three-Dimensional Consolidation

            Bookmark
            • Record: found
            • Abstract: not found
            • Article: not found

            An Algorithm for Finding Best Matches in Logarithmic Expected Time

              Bookmark
              • Record: found
              • Abstract: not found
              • Article: not found

              Iterative point matching for registration of free-form curves and surfaces

                Bookmark

                Author and article information

                Journal
                Medical Physics
                Med. Phys.
                Wiley
                00942405
                July 2003
                June 23 2003
                June 23 2003
                : 30
                : 7
                : 1671-1682
                Article
                10.1118/1.1578911
                4445740
                12906184
                ddbaedf9-2142-44d1-aaa1-9c2e925d769d
                © 2003

                http://doi.wiley.com/10.1002/tdm_license_1.1

                History

                Comments

                Comment on this article