          Abstract

          Clinicians should be aware of new developments to familiarize themselves with pharmacokinetic and pharmacodynamic characteristics of new anticoagulant agents to appropriately and safely use them. For the moment, cardiologists and other clinicians also require to master currently available drugs, realizing the mechanism of action, side effects, and laboratory monitoring to measure their anticoagulant effects. Warfarin and heparin have narrow therapeutic window with high inter- and intra-patient variability, thereby the use of either drug needs careful laboratory monitoring and dose adjustment to ensure proper antithrombotic protection while minimizing the bleeding risk. The prothrombin time (PT) and the activated partial thromboplastin time (aPTT) are laboratory tests commonly used to monitor warfarin and heparin, respectively. These two tests depend highly on the combination of reagent and instrument utilized. Results for a single specimen tested in different laboratories are variable; this is mostly attributable to the specific reagents and to a much lesser degree to the instrument used. The PT stands alone as the single coagulation test that has undergone the most extensive attempt at assay standardization. The international normalized ratio (INR) was introduced to “normalize” all PT reagents to a World Health Organization (WHO) reference thromboplastin preparation standard, such that a PT measured anywhere in the world would result in an INR value similar to that which would have been achieved had the WHO reference thromboplastin been utilized. However, INRs are reproducible between laboratories for only those patients who are stably anticoagulated with vitamin K antagonists (VKAs) (i.e., at least 6 weeks of VKA therapy), and are not reliable or reproducible between laboratories for patients for whom VKA therapy has recently been started or any other clinical conditions associated with a prolonged PT such as liver disease, disseminated intravascular coagulation, and congenital factor deficiencies. In contrast to marked progress in the standardization of PT reagents for INR reporting, no standardization system has been globally adopted for standardization of PTT reagents. Recently College of American Pathologists recommend that individual laboratories establish their own therapeutic range by using aPTT values calibrated against accepted therapeutic unfractionated heparin (UFH) levels calibrated against accepted therapeutic UFH levels performing anti-Xa test (which is the most accurate assay for monitoring UFH therapy).

          Herein, we review recent data on the monitoring of conventional anticoagulant agents. Marked interlaboratory variability still exists for PT, INR, and PTT tests. Further research should be focused on improving the standardization and calibration of these assays.

          Related collections

          Most cited references81

          • Record: found
          • Abstract: found
          • Article: not found

          Heparin and low-molecular-weight heparin: the Seventh ACCP Conference on Antithrombotic and Thrombolytic Therapy.

          This article about unfractionated heparin (UFH) and low-molecular-weight heparin (LMWH) is part of the Seventh American College of Chest Physicians Conference on Antithrombotic and Thrombolytic Therapy: Evidence-Based Guidelines. UFH is a heterogeneous mixture of glycosaminoglycans that bind to antithrombin via a pentasaccharide, catalyzing the inactivation of thrombin and other clotting factors. UFH also binds endothelial cells, platelet factor 4, and platelets, leading to rather unpredictable pharmacokinetic and pharmacodynamic properties. Variability in activated partial thromboplastin time (aPTT) reagents necessitates site-specific validation of the aPTT therapeutic range in order to properly monitor UFH therapy. Lack of validation has been an oversight in many clinical trials comparing UFH to LMWH. In patients with apparent heparin resistance, anti-factor Xa monitoring may be superior to measurement of aPTT. LMWHs lack the nonspecific binding affinities of UFH, and, as a result, LMWH preparations have more predictable pharmacokinetic and pharmacodynamic properties. LMWHs have replaced UFH for most clinical indications for the following reasons: (1) these properties allow LMWHs to be administered subcutaneously, once daily without laboratory monitoring; and (2) the evidence from clinical trials that LMWH is as least as effective as and is safer than UFH. Several clinical issues regarding the use of LMWHs remain unanswered. These relate to the need for monitoring with an anti-factor Xa assay in patients with severe obesity or renal insufficiency. The therapeutic range for anti-factor Xa activity depends on the dosing interval. Anti-factor Xa monitoring is prudent when administering weight-based doses of LMWH to patients who weigh > 150 kg. It has been determined that UFH infusion is preferable to LMWH injection in patients with creatinine clearance of < 25 mL/min, until further data on therapeutic dosing of LMWHs in renal failure have been published. However, when administered in low doses prophylactically, LMWH is safe for therapy in patients with renal failure. Protamine may help to reverse bleeding related to LWMH, although anti-factor Xa activity is not fully normalized by protamine. The synthetic pentasaccharide fondaparinux is a promising new antithrombotic agent for the prevention and treatment of venous thromboembolism.
            Bookmark
            • Record: found
            • Abstract: found
            • Article: not found

            Diagnosis and monitoring of hepatic injury. I. Performance characteristics of laboratory tests.

            To review information on performance characteristics for tests that are commonly used to identify acute and chronic hepatic injury. A MEDLINE search was performed for key words related to hepatic tests, including quality specifications, aminotransferases, alkaline phosphatase, gamma-glutamyltransferase, bilirubin, albumin, ammonia, and viral markers. Abstracts were reviewed, and articles discussing performance of laboratory tests were selected for review. Additional articles were selected from the references. Guideline Preparation and Review: Drafts of the guidelines were posted on the Internet, presented at the AACC Annual Meeting in 1999, and reviewed by experts. Areas requiring further amplification or literature review were identified for further analysis. Specific recommendations were made based on analysis of published data and evaluated for strength of evidence and clinical impact. The drafts were also reviewed by the Practice Guidelines Committee of the American Association for the Study of Liver Diseases and approved by the committee and the Association's Council. Although many specific recommendations are made in the guidelines, some summary recommendations are discussed here. Alanine aminotransferase is the most important test for recognition of acute and chronic hepatic injury. Performance goals should aim for total error of <10% at the upper reference limit to meet clinical needs in monitoring patients with chronic hepatic injury. Laboratories should have age-adjusted reference limits for enzymes in children, and gender-adjusted reference limits for aminotransferases, gamma-glutamyltransferase, and total bilirubin in adults. The international normalized ratio should not be the sole method for reporting results of prothrombin time in liver disease; additional research is needed to determine the reporting mechanism that best correlates with functional impairment. Harmonization is needed for alanine aminotransferase activity, and improved standardization for hepatitis C viral RNA measurements.
              Bookmark
              • Record: found
              • Abstract: found
              • Article: not found

              Mistakes in a stat laboratory: types and frequency.

              Application of Total Quality Management concepts to laboratory testing requires that the total process, including preanalytical and postanalytical phases, be managed so as to reduce or, ideally, eliminate all defects within the process itself. Indeed a "mistake" can be defined as any defect during the entire testing process, from ordering tests to reporting results. We evaluated the frequency and types of mistakes found in the "stat" section of the Department of Laboratory Medicine of the University-Hospital of Padova by monitoring four different departments (internal medicine, nephrology, surgery, and intensive care unit) for 3 months. Among a total of 40490 analyses, we identified 189 laboratory mistakes, a relative frequency of 0.47%. The distribution of mistakes was: preanalytical 68.2%, analytical 13.3%, and postanalytical 18.5%. Most of the laboratory mistakes (74%) did not affect patients' outcome. However, in 37 patients (19%), laboratory mistakes were associated with further inappropriate investigations, thus resulting in an unjustifiable increase in costs. Moreover, in 12 patients (6.4%) laboratory mistakes were associated with inappropriate care or inappropriate modification of therapy. The promotion of quality control and continuous improvement of the total testing process, including pre- and postanalytical phases, seems to be a prerequisite for an effective laboratory service.
                Bookmark

                Author and article information

                Journal
                J Tehran Heart Cent
                J Tehran Heart Cent
                JTHC
                The Journal of Tehran Heart Center
                Tehran University of Medical Sciences
                1735-5370
                2008-2371
                Spring 2010
                2010
                31 May 2010
                : 5
                : 2
                : 57-68
                Affiliations
                Tehran Heart Center, Tehran University of Medical Sciences, Iran
                Author notes
                [* ]Corresponding Author: Mohammad Ali Boroumand, Associate Professor of Pathology, Tehran Heart Center, North Kargar Street, Tehran, Iran. 1411713138. Tel: +98 21 88029231. Fax: +98 21 88029231. E-mail: borumand@ 123456sina.tums.ac.ir .
                Article
                jthc-5-57
                3466827
                23074569
                dea236e0-42e7-4c31-86a7-6f6f3f170027
                Copyright © Tehran Heart Center, Tehran University of Medical Sciences

                This is an open-access article distributed under the terms of the Creative Commons Attribution NonCommercial 3.0 License (CC BY-NC 3.0), which allows users to read, copy, distribute and make derivative works for non-commercial purposes from the material, as long as the author of the original work is cited properly.

                History
                Categories
                Review Article

                Cardiovascular Medicine
                international normalized ratio,partial thromboplastin,heart,anticoagulants,prothrombin time

                Comments

                Comment on this article